| 1 | Supply and fix in repairs sealed compressor suitable for 1.5 Ton Window/Split type AC and making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/Sriram or equivalent. Note : (a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out from authorized dealers of original manufacturer's only. |
| 2 | Supply and fix in repairs sealed compressor suitable for 2 Ton Window/Split type AC and making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/Sriram or equivalent. Note : (a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out from authorized dealers of original manufacturer's only. |
| 3 | Supply and fix in repairs running capacitor 36 MFD, 3 Pole & 2 Pole suitable for 1.5 Ton window / split type air conditioner all as specified and as directed by Engineer-in-Charge. Make : Asian/Unister/Apcos/Electro. |
| 4 | All as per item No. 3 described here-in-before but capacitor 45 MFD for 2 ton window / split type air conditioner |
| 5 | Supply and fix in repairs starting capacitor, 80 to 100 MFD suitable for 1.5 Ton window / split type air conditioner complete all as specified and as directed by Engineer-in-Charge.Make : Asian/Unister/Apcos/Electro |
| 6 | All as per item No. 5 described here-in-before but capacitor 100 to 150 MFD for 2.0 Ton window / split type air conditioner |
| 7 | Supply & Fix in repair starting relay with new starting relay suitable for 1.5/2 TR air conditioner complete all as specified and directed by Engr-in-charge. |
| 8 | Supply & Fix in repair thermostat control switch for window/ split type Air Conditioner of 1.5 Ton /2.0 TR cap coimplete all as specified and directed by Engr-in-charge.Make : Renutral, Denfos or equivelent. |
| 9 | Material and labour for gas charging R-134A/ R-32/ R-410A in window/ split type AC 1.5 Ton capacity of any make and type, including pressure leakage testing, vacuuming, rectification, testing and commissioning including suitable size copper tubing complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material and labour for gas charging R-134A/ R-32/R-410A in window/ split type AC 2 Ton capacity of any make and type, including pressure leakage testing, vacuuming, rectification, testing and commissioning including suitable size copper tubing complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply and fix in repairs copper condenser coil assembly for 1.5 Ton AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Gas charging shall be measured and paid separately |
| 12 | Supply and fix in repairs copper condenser coil assembly for 2.0 Ton of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Gas charging shall be measured and paid separately |
| 13 | Material and labour for taking down window type / split type air conditioner of any type/make/capacity after dismantling all electric connection from site (either in ground / any floor), transporting to work site, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, descaling with acid on both side of cooling coil and components, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fix in replacement of invertor electric writing kit (PCB) for indoor unit suitable for 1.5 Ton / 2.0 Ton window / split type AC complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of invertor electric writing kit (PCB) for outdoor unit suitable for 1.5 Ton / 2.0 Ton window / split type AC complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fix in repairs Mild Steel bracket (heavy duty), duly powder coated paint, suitable for outdoor unit of split AC 1.5/2.0 ton capacity including 8 Nos anchor bolt 12mm dia x 80mm long complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fix in repairs defective front cover grill with new front cover grill suitable for window type air conditioner of capacity 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed. |
| 18 | Supplying, fixing and testing of fan blade of motor for window / split type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton including taking down of old fan blade and removing complete all as specified and as directed by Engineer-in-Charge |
| 19 | Supply and fix in repairs blower fan motor for 1.0 Ton / 1.5 Ton /2.0 Ton capacity, window / split type Air conditioners including testing, complete all as specified and as directed. |
| 20 | Supply and fix in repairs blower drum, suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge |
| 21 | Supply and fix in repairs blower, suitable for split type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge |
| 22 | Supply and fix in repairs indoor unit for split type Air Conditioner of 1.5 Ton capacity with all internal parts complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG. |
| 23 | Supply and fix in repairs capacitor 4 MFD for window type air conditioner of capacity 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed. |
| 24 | Supply and fix in repairs capacitor 6 MFD for window type air conditioner of capacity 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed. |
| 25 | Material and labour for shifting of window type/spilt type AC of any capacity and make, after dismantling of all electrical connection and carrying it to the new location, refixing it after making suitable size hole in wall, making electrical connections, installation testing, commissioning and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge |
| 26 | Supply and fix in repairs of swing motor suitable for window/ spilt type AC complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Supply and fix in repairs sealed compressor suitable for Water cooler of capacity 40/80 litres, making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/SriramNote :(a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out by original company's authorized dealer only. |
| 28 | Material and labour for gas charging R-134 A in water cooler of capacity 40/80 ltrs including pressure leakage testing, vacuuming, rectification, testing of entire unit and commissioning including provision of suitable size copper tubing complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Supply and fix in repairs starting capacitor 40-60 MFD for water cooler complete all as specified and as directed by Engineer-in-Charge.Make : Asian/Unistar/Tibcon/Telsa |
| 30 | Supply and fix in repairs running capacitor 10 MFD for water cooler complete all as specified and as directed by Engineer-in-Charge.Make : Asian/Unistar/Tibcon/Telsa |
| 31 | Supply and fix in repairs thermostatic control switch for water cooler complete all as specified and as directed by Engineer-in-Charge.Make : Renutral/Ind foss/Annapurna (AES) |
| 32 | Supply and fix in repairs condenser fan motor 1/35 HP, 230 volts, AC, single phase suitable for water cooler all as specified and as directed by Engineer-in-Charge.Make : AUE / Flare Master or equivalent |
| 33 | Supply and fix in repairs relay for water cooler of suitable capacity all as specified and as directed by Engineer-in-Charge. |
| 34 | Supply and fix in repairs push cock/ lifting cock of 15mm dia cast copper alloy,chromium plated suitable for water cooler, complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Supply and fix in replacement of water tray stainless steel of 40/80 litre capacity all as specified and as directed by Engineer-in-Charge. |
| 36 | Supply and fix in replacement of rubber packing and hinges of top cover of any water cooler of any make and capacity all as specified and as directed by Engineer-in-Charge. |
| 37 | Supply and fix in repairs Ball Valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed of 15 mm bore complete all as specified and as directed by Engineer-in-Charge (Minimum weight - 142 gms) Make :Prayag or equivalent as approved by GE. |
| 38 | Supply and fix as in repair over load protector for water cooler of any capacity complete all as per specified and as directed. |
| 39 | Material and labour for preparation of old painted steel surfaces of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom frame etc for the 40/80 litre capacity water coolers etc complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fix and testing of fan blade of motor for water cooler any type and size including taking down of old fan blade and removing, complete all as specified and directed |
| 41 | Supply and fix in repairs sealed compressor suitable for Refrigerator 165 to 392 litre capacity and making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/Sriram or equivalent. Note : (a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out from authorized dealers of original manufacturer's only. |
| 42 | All as per item No. 41 described here-in-before but for 300 to 320 litre capacity |
| 43 | All as per item No. 41 described here-in-before but for 355 to 500 litre capacity |
| 44 | Material and labour for gas charging R-134A / R-600 in Refrigerator of 165 to 292 litre capacity including pressure testing leakage, Vacuuming, rectification, testing and commissioning including suitable size copper tubing complete all as specified and as directed by Engineer-in-Charge |
| 45 | All as per item No. 44 described here-in-before but for 300 to 320 litre capacity |
| 46 | All as per item No. 44 described here-in-before but for 355 to 500 litre capacity |
| 47 | Supply and fix in repairs thermostat control switch for refrigerator of any capacity, complete all as specified and as directed by Engineer-in-Charge.Make : Renutral, Sriram/Kalvinator/Godrej/Kirloskar |
| 48 | Supply and fix in repairs overload protector suitable for high / low speed for refrigerator any capacity complete all as specified and as directed by Engineer-in-ChargeMake : Renutral, Sriram/Kalvinator/Godrej/Kirloskar |
| 49 | Taking out old unserviceable magnetic gasket and supply and fix new magnetic gasket for refrigerator of 165 to 500 litres capacity all as specified and as directed by Engineer-in-Charge. |
| 50 | Supply and fix in repairs relay for refrigerator of 360 litres capacity all as specified and as directed by Engineer-in-Charge. |
| 51 | Supply and fix as in repairs timer for refrigerator of 300 to 500 litres capacity all as specified and as directed by Engineer-in-Charge. |
| 52 | Supply and fix in repairs of chiller door for refrigerator all as specified and as directed by Engineer-in-Charge. |
| 53 | Supply and fix in repairs of chiller tray for refrigerator all as specified and as directed by Engineer-in-Charge. |
| 54 | Supply and fix copper pipe for 1.5 ton capacity AC, 1/2\\" , 50mm with all accessories etc complete all as specified and as directed by Engineer-in-Charge.Make: Godrej |
| 55 | Supply and fix copper pipe for 1.5 ton capacity AC, 1/4\\" OD, 6.35mm and ID 5.09mm, 50mm plumbing pipe( Copper) with all accessories etc complete all as specified and as directed by Engineer-in-Charge.Make: Godrej |
| 56 | Supply and fix 3 core PVC insulated and unsheathed, unarmoured, multistranded, copper conductor cable of size 4.0 Sqmm, 1100 Volts grade for AC connection etc complete all as specified and as directed by Engineer-in-Charge.Make- Plaza, Finolex, Havells, Polycab |
| 57 | Supply and fix in repairs single pole and neutral enclosure with a three pin & earth plug with socket complete with one single pole MCB 20 to 30 Amps, 240Volts, 'C series, 50 Hz , breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.Make :Legrand / L&T / Havells/Benlo |
| 58 | Supply and fix in repairs MCB SP 6-32 Amps, 240 volts, 10KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.Make :Legrand / L&T / Havells/Benlo |
| 59 | Material and labour for submain wiring complete with and including 2 runs of 4.0sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit, heavy duty of suitable size including accessories etc as required and fixed on walls and 4.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 4.0sqmm PVC insulated cable and one run of 4.0sqmm cable and one run of PVC conduit/ casing capping shall be measured as one unit length.Make of Cable-Plaza, Finolex, Havells, PolycabMake of PVC conduit/Casing Capping-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 60 | Supply only remote control for 1.5T/2.0 Ton inverter/non inverter AC of any type & make as per sample complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG. |
| 61 | Supply and fix in repairs outdoor unit for split type Air Conditioner of 1.5 Ton capacity consisting of compressor, condenser coil, blower motor with fan etc including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG. |
| 62 | Supply and fix in repairs outdoor unit for split type Air Conditioner of 2.0 Ton capacity consisting of compressor, condenser coil, blower motor with fan etc including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG. |
| 63 | Supply only 5 KVA voltage stabilizer, single phase, 230 volts output( (+/- 1%), full load up to 20 Amp gives protection against low voltage, high voltage and over load trip complete all as specified and as directed by Engineer-in-Charge.Make :V-Guard / Schneider / Havells/Godrej |
| 64 | Supply and fix in repairsAC drain pipe for spilt type AC of capacity 1.5 Ton/ 2.0 Ton for water outlet durable & flexible PVC pipe of appropriate size complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG. |
| 65 | Supplying, fixing and testing of fan motor for condenser capacity 11.5 Ton Capacity including taking down of old fan blade and removing complete all as specified and as directed by Engineer-in-Charge |
| 66 | Supplying, fixing and testing of condenser fan blade of capacity 11.5 Ton Capacity including taking down of old fan motor and removing complete all as specified and as directed by Engineer-in-Charge |
| 67 | Supplying and fixing in repairs thermostat expansion valve for Air Conditioner of 11.5 Ton Capacity complete all as specified and as directed by Engineer-in-Charge.Make : Renutral, Denfos or equivalent. |
| 68 | Supply and fix in repairs thermostat for Air Conditioner of 11.5 Ton Capacity complete all as specified and as directed by Engineer-in-Charge.Make : Renutral, Denfos or equivalent. |
| 69 | Supply and fix in repairs solenoid valve for Air Conditioner of 11.5 Ton Capacity complete all as specified and as directed by Engineer-in-Charge.Make : Renutral, Denfos or equivalent. |
| 70 | Supply, fix and testing of fan motor for cooling unit capacity 11.5 Ton Capacity AC including taking down of old fan motor and removing complete all as specified and as directed by Engineer-in-Charge |
| 71 | Supply, fix and testing of fan blade for cooling unit capacity 11.5 Ton Capacity AC including taking down of old fan blade and removing complete all as specified and as directed by Engineer-in-Charge |
| 72 | Supply and fix in repairs outdoor unit power contactor for Air Conditioner of 11.5 Ton Capacity AC including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG. |
| 73 | Supply and fix in repairs indoor unit of Air Conditioner of 2 Ton Capacity spilt with all internal parts complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG/ Godrej |
| 74 | Supply and fix in repairs coil heater for 11.5 Ton Capacity AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and fix in replacement of invertor electric writing kit (PCB) for indoor unit suitable for 11.5 Ton Capacity, window / split type AC complete all as specified and as directed by Engineer-in-Charge. |
| 76 | Supply and fix in replacement of invertor electric writing kit (PCB) for outdoor unit suitable for 11.5 Ton Capacity, window / split type AC complete all as specified and as directed by Engineer-in-Charge. |
| 77 | Supply and fix 4 core PVC insulated and unsheathed, unarmoured, multistranded, copper conductor cable of size 1.5 Sqmm, 1100 Volts grade for AC connection etc complete all as specified and as directed by Engineer-in-Charge.Make- Plaza, Finolex, Havells, Polycab |
| 78 | Material and labour for submain wiring complete with and including 2 runs of 6.0sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including PVC Casing capping, heavy duty of suitable size including accessories etc as required and fixed on walls and 6.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 6.0sqmm PVC insulated cable and one run of 6.0sqmm cable and one run of PVC casing capping shall be measured as one unit length.Make of Cable-Plaza, Finolex, Havells, PolycabMake of PVC conduit/Casing Capping-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 79 | Material and labour for submain wiring complete with and including 2 runs of 4.0sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including PVC Casing capping, heavy duty of suitable size including accessories etc as required and fixed on walls and 4.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 4.0sqmm PVC insulated cable and one run of 4.0sqmm cable and one run of PVC casing capping shall be measured as one unit length.Make of Cable-Plaza, Finolex, Havells, PolycabMake of PVC conduit/Casing Capping-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 80 | Supply and fix in repairs sealed compressor suitable for 11.5 Ton Capacity AC and making all necessary connection with suction, discharge and charging pipe line with gas welding, including initial testing complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Techmech/Aircon/Usha/Sriram or equivalent. Note : (a) Gas charging shall be measured and paid separately. (b) Replacement of compressor unit shall be carried out from authorized dealers of original manufacturer's only. |
| 81 | Material and labour for gas charging R-404A in AC 11.5 Ton capacity AC of any make and type, including pressure leakage testing, vacuuming, rectification, testing and commissioning including suitable size copper tubing complete all as specified and directed by Engineer-in-Charge. |
| 82 | Supply and fix in repairs copper condenser coil assembly for 11.5 Ton Capacity AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Gas charging shall be measured and paid separately |
| 83 | Material and labour for taking down air conditioner(indoor & outdoor) of any type/make/ of 11.5 Ton capacity AC after dismantling all electric connection from site (either in ground / any floor), transporting to work site, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, decaling with acid on both side of cooling coil and components, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge. |
| 84 | Supply and fix in repairs evaporator coil assembly for 11.5 Ton Capacity AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Gas charging shall be measured and paid separately |
| 85 | Supply and fix in repairs indoor unit contactor for Air Conditioner of 1.5 Ton Capacity spilt invertor AC with all internal parts including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Carrier/LG/Godrej |
| 86 | Supply and fix in repairs temperature display unit with panel for 11.5 Ton capacity AC of any type and any make, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 87 | Note: Deduct Credit for demolished / dismantled material of Rs. (-) 35,225.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Please Enable Macros to View BoQ information |