Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork, Sand filling |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including taking out and disposal of excavated earth within site and lift upto 1.5 m, disposed soil to be levelled and neatly dressed as directed by Engineer-in-charge. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 4 | i) All kinds of Soil |
| 5 | Extra for levelling & neatly dressing of disposed soil completely as directed by engineer in charge |
| 6 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
| 7 | Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil |
| 8 | ii) For extra depth of >1.5m < 3m for dia upto 80mm |
| 9 | iv) Pipes, Cable etc. > 80mm < 300m dia |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. |
| 11 | i) All kinds of Soil |
| 12 | Close timbering in case of shafts, wells, cesspits, manholes & the like including strutting, shoring & packing cavities (wherever reqd)etc complete(Measurements to be taken of the face area timbered) |
| 13 | i) Close timbering in trench depth not exceeding 1.5m |
| 14 | ii) Close timbering in trench depth >1.5m < 3m |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 16 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
| 17 | i) Local Fine Sand within grading zone IV |
| 18 | Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete |
| 19 | Supply & backfilling with 75mm thick murrum for brick/stone pitching or under driveway in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming,watering and dressing complete |
| 20 | Carriage charge for disposal of earth by mechanical means, including loading, transporting, stacking, unloading to approved municipal dumping ground / unobjectionable place as per direction of Engineer- in-Charge beyond IOCL Premises for all leads and including all lifts. |
| 21 | i) Distance upto 1 km |
| 22 | ii) Distance > 1 km< 3 km |
| 23 | iii) Distance > 3 km< 5 km |
| 24 | iv) Distance > 5 km< 10 km |
| 25 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. |
| 26 | i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired |
| 27 | ii) With material confirming to grade-II (size 53 mm to .075 mm) having CBR value -25,Thickness as desired |
| 28 | Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. |
| 29 | Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer |
| 30 | Concrete Work (PCC) |
| 31 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 32 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 33 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 34 | vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) |
| 35 | viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) |
| 36 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil |
| 37 | Painting top of roofs with residual type petroleum bitumen of grade VG10 of approved quality at 17kg per10sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil complete. |
| 38 | REINFORCED CEMENT CONCRETE (RCC) WORK |
| 39 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 40 | i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm |
| 41 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 42 | Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : |
| 43 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 44 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 45 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 46 | ii) Walls (any thickness) including attached pilasters, buttress, plinth and string courses etc. |
| 47 | iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) |
| 48 | iv) Lintels, beams plinth beams,girders bressumers and cantilevers |
| 49 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 50 | vi) Stairs, (excluding landings) except spiral-staircases |
| 51 | vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 52 | viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick |
| 53 | ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick |
| 54 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix manufactured in fully automatic batching plant & transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing & reinforcement including cost of admixtures in recommended proportions as per IS:9109 to accelerate/ retard setting of concrete, improve workability without impairing strength & durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable. |
| 55 | i) M25 RMC for All works UP TO PLINTH LEVEL |
| 56 | ii) M25 RMC for All works ABOVE PLINTH UPTO FLOOR 5 LEVEL |
| 57 | Extra for providing richer mixes at all floor levels. Note:- Less cement over the specified cement content used is recoverable separately. No extra payment against extra cement if used shall be payable. |
| 58 | i) Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). |
| 59 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 60 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 61 | BRICK WORK |
| 62 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 63 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 64 | iii) Brick work in Cement mortar 1:4 (1 cement: 4 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL |
| 65 | v) Extra for brick work/AAC Block Masonry/Tile Brick Masonry in superstructure above floor V level for each four floors or part thereof by mechanical means |
| 66 | xvi) Half brick masonry with Class designation 5.0 bricks in Cement mortar 1:4 ( 1 cement : 4 coarse sand) IN superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL |
| 67 | FLOORING |
| 68 | Brick on edge flooring with bricks of Class designation 7.5 on a bed of 12mm cement mortar including filing the joints with same mortar with common burnt clay non modular bricks |
| 69 | i) cement mortar 1:4 (1 cement : 4 fine sand) |
| 70 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 71 | 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 72 | 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound is mixed @2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, 2 mm thick PVC strip at desired spacing, cost of nosing in steps etc. complete. |
| 73 | 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 74 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand)jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing and polishing complete. |
| 75 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. |
| 76 | ii) Granite work |
| 77 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters & similar location in marble/Granite/stone work including necessary holes for pillar taps etc.including rubbing and polishing of cut edges etc.complete |
| 78 | 18mm thick Cement plaster skirting with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement. |
| 79 | Stone flooring with 18mm thick Marble/Granite stone (sample of stone shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry including rubbing and polishing complete |
| 80 | iii) Black Zebra or Cuddapa (30mm thick) Stone |
| 81 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 82 | iii) Granite of any colour and shade having Area of slab upto 0.50 sqm |
| 83 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 84 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified |
| 85 | i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 86 | ii) Flooring with size of Tiles 80x80Cm in cement mortar 1:4 |
| 87 | iii) Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 |
| 88 | iv) Skirting with size of Tiles 80x80Cm in cement mortar 1:3 |
| 89 | v) Flooring with size of Tiles 60x120Cm in cement mortar 1:4 |
| 90 | vi) Flooring with size of Tiles 30x60Cm in cement mortar 1:4 |
| 91 | vii) Skirting with size of Tiles 60x120Cm in Cement mortar 1:3 |
| 92 | viii) Skirting with size of Tiles 30x60Cm in cement mortar 1:3 |
| 93 | Providing & laying vitrified floor tile Matt/Antiskid finish in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified by Engineer-in-charge. |
| 94 | i) Flooring with size of Tiles 30x30Cm in cement mortar 1:4 |
| 95 | ii) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 96 | iii) Flooring with size of Tiles 80x80Cm in cement mortar 1:4 |
| 97 | Providing and laying matt finished vitrified tile of following size having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 98 | i) Flooring with size of Tiles 40x40Cm in cement mortar 1:4 |
| 99 | Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. |
| 100 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. |
| 101 | vi) Granite stone/Makrana White second quality in flooring |
| 102 | Providing and laying brick tiles of over mumty roofs grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1cement:3 fine sand) finished neat with common burnt clay FPS (non modular) of class designation 10 |
| 103 | Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) |
| 104 | ii) M40 grade 80 mm thick reflective type Lacquered finish |
| 105 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement |
| 106 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make & colour using acid and/or alkali resisting mortar bedding and filling joints with acid and/or alkali resisting cement as per IS:4457, all complete as per specifcations and directions of the Engineer-in-Charge : |
| 107 | In flooring on a bed of 10 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) : |
| 108 | In dado/ skirting on 12 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) : |
| 109 | FALSE CEILING, GLASS PARTITION |
| 110 | Providing and fixing of toughened glass with suitable arrangement, all complete as per drawing, specification and direction of Engineer-in-Charge |
| 111 | i) 8 mm thick |
| 112 | ii) 10 mm thick |
| 113 | iii) 12 mm thick |
| 114 | Providing & fixing at all height FALSE CEILING including providing & fixing of frame work made of special sections power pressed from M.S. sheets and galvanised with zinc coating 120gsm/sqm as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts ,other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length, and with nut and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x 0.9mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the perimeter channels 0.5mm thick 27mm high having flanges of 20mm & 30mm long, the perimeter of ceiling fixed to wall partition with the help of rawl plugs at 450mm centre to centre with 25 mm long drive-all screws @ 230mm interval including jointing & fixing of gypsum board of ceiling section & perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm centre to centre including jointing and finishing to a flush finish of tapered & square edges of the board with recommended jointing compoud. Jointing tapes, finishing with jointing compoud in 3 layers covering upto 150 mm on both sides of joint & 2 coats of primer suitable for board, all as per manufacturer specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, complete as per drawing & specification and direction of the Engineer in Charge but excluding the cost of painting with: |
| 115 | i) 12.5mm thick tapered edge fire resistant GYPSUM BOARD conforming to IS:2095- PART-I:2011 (board with BIS Certification marks) |
| 116 | Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves & wooden screws at 300mm center to centre,suspending the main C carrier of size 10x38x10mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6mm,rawl plugs of size 38x12mm & C carrier suspension clip and main carrier bracket at 1000mm c/c. Inverted triangle shaped Spring Tee having ht. of 24mm & width of 34mm made of GI steel 0.45mm thick is then fixed to the main C carrier & in direction perpendicular to it at 600mm centers with help of suspension brackets.Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive) Fixing with clip in tiles into spring 'T' with: |
| 117 | ii) GI Metal Ceiling Clip in plain Bevelled edge global white colour tiles of size 600x600 & 0.5mm thick with 25mm height, made of GI Sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes & having NRC of 0.5, electrostatically ,polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation |
| 118 | Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick wrapped in 200G Virgin Polythene Bags fixed to wall with screw,rawel plug and washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. |
| 119 | Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS:8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24g wire and mesh, for top most ceiling of building. |
| 120 | FINISHING WORKS: PLASTERING, PUTTY, PAINTING, WATER PROOFING, BRICK ELEVATION TILE, GROOVING ETC. |
| 121 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 122 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 123 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 124 | iii) 15mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) on rough side of half or single brick wall |
| 125 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. |
| 126 | iv) 15mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) on rough side of half or single brick wall |
| 127 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. |
| 128 | i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 129 | Providing Neat cement punning |
| 130 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 131 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 132 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 133 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats |
| 134 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 135 | Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 136 | Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand & manufacture on steel galvanised iron/steel works |
| 137 | Finishing with Epoxy paint, 2 or more coats at all locations on steel work prepared & applied as per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. |
| 138 | Finishing with Epoxy paint, 2 or more coats at all location on concrete work prepared & applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. |
| 139 | Lettering with black japan paint of approved brand & manufacture and (unit/letter/cm ht) |
| 140 | Add for plaster drip course/groove in plastered surface or moulding to all type of RCC projections |
| 141 | Providing and fixing 150 mm wide Chicken Wire mesh between junctions of column/beam and walls, fixed with U nails 150 mm centre to centre before plastering the junction. |
| 142 | ALUMINIUM WORKS/ UPVC WORKS |
| 143 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over, backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth and width of profile shall be acceptable. |
| 144 | Fixed window / ventilator made of (small series) frame 47 x 50 mm and mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 145 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth and width of profile shall be acceptable. |
| 146 | Two track two panels sliding window made of (small series) frame 52 x 44 mm and sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 147 | Two track two panels sliding window made of (big series) frame 67 x 50 mm and sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm). |
| 148 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 149 | i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections |
| 150 | iv) For shutters of doors, windows & ventilators with Polyester Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 151 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 152 | ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) |
| 153 | iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) |
| 154 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 155 | ii) With brass cover plate minimum 1.25 mm thickness |
| 156 | Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. |
| 157 | ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) |
| 158 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per direction of Engineer in Charge complete Upto 5mm depth and 5mm width |
| 159 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 160 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 161 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length) fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60mm long and stainless steel expandable dash fastener 12.5 mm dia. and 50mm long complete as per direction of Engineer-in-charge. |
| 162 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge. |
| 163 | i) Powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 164 | ii) Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 165 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 166 | Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete |
| 167 | STEEL WORKS |
| 168 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 169 | Providing & fixing in position collapsible steel shutter with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 170 | Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. |
| 171 | i) Hot finished welded type tubes |
| 172 | Fabrication & Erection of IOC supplied structural steel work riveted, bolted or welded in single/ built up sections,trusses & framed work hoisting, fixing in position and applying a priming coat of approved steel primer all including cutting, complete |
| 173 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. |
| 174 | Providing & fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick MS sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. |
| 175 | Providing and fixing stainless steel (SS 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting with necessary stainless steel nuts and bolts complete including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of the waist slab with suitable arrangement, all complete as per specification and direction of Engineer-in-charge. |
| 176 | Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete. |
| 177 | Providing & fixing fly proof galvanised M.S. wire gauze to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm with 2nd class teak woodbeading 62x19 mm all complete |
| 178 | Sanitary Works |
| 179 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 180 | iii) 200 mm dia |
| 181 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). |
| 182 | iii) 200 mm dia |
| 183 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 184 | iii) 25 mm nominal outer dia Pipes |
| 185 | iv) 32 mm nominal outer dia Pipes |
| 186 | vi) 50 mm nominal outer dia Pipes |
| 187 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. |
| 188 | ii) 20 mm nominal outer dia Pipes |
| 189 | iii) 25 mm nominal outer dia Pipes |
| 190 | Providing and fixing brass bib cock of approved quality : |
| 191 | i) 15 mm nominal bore |
| 192 | ii) 20 mm nominal bore |
| 193 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 194 | Providing and fixing C.P. brass angle valve for basin mixer & geyser points of approved quality conforming to IS:8931 - 15mm nominal bore |
| 195 | Providing and fixing C.P. brass stop cock (concealed) of standard design & of approved make conforming to IS:8931 - 15 mm nominal bore. |
| 196 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25,of size1000x450x50mm, reinforced with 8mm dia four nos longitudinal & 9nos cross sectional T.M.T.hoop bars,including providing 50mm dia perforations @100 to125 mm c/c, including providing edge binding with M.S. flats of size 50mm x 1.6 mm complete, all as per direction of Engineer-in-charge. |
| 197 | Providing and fixing of Automatic Soap/ Sanitizer Dispenser with all fittings and all complete, as per specification and direction of Engineer-in-charge. |
| 198 | Providing and fixing of SS single Soap tray with all fittings and all complete, as per specification and direction of Engineer-in-charge. |
| 199 | Providing and fixing Chrome Finish SS Health faucet with 8mm dia, 1 meter long SS braided rubber hose pipe and wall hook with N.R.V, Jaguar make cat. No. ALD-577 or equivalent all complete, as per specification and direction of Engineer-in-charge. |
| 200 | Providing and fixing of SS single Soap tray with all fittings and all complete, as per specification and direction of Engineer-in-charge. |
| 201 | Providing and fixing 450 mm long CP Brass towel rail complete with brackets fixed to wooden/PVC cleats with SS screws with concealed fittings arrangement of Make: Cera F5007104 or equivalent all complete and as per direction of Engineer-in-charge. |
| 202 | Providing and fixing front operated concealed cistern Kohler cat no- K-77029IN-M-NA or equivalent make with loop type actuator plate complete including integrated angle stop valve, flush bend with protective cover, slotted flat irons, fastening brackets and flushing pipe etc. as per specification and direction of Engineer-in-charge. |
| 203 | Providing and fixing first quality (heavy duty) type glazed vitreous china P or S trap Wall hung coloured water closet, seat cover, CP nuts, bolts and other necessary fittings all complete and as per specification and direction of Engineer-in-charge. |
| 204 | Providing and fixing H type double tone SS Pull handle of GODREJ (7268) or equivalent make with all tools, tackles etc. all complete, as per specification and direction of Engineer-in-charge. |
| 205 | Providing & fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 206 | i) 200x10 mm |
| 207 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
| 208 | Providing & fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). |
| 209 | Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of : |
| 210 | ii) Size 75 |
| 211 | Providing & fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. |
| 212 | Providing & fixing chromium plated brass handles with necessary screws etc. complete: |
| 213 | i) 125 mm |
| 214 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 215 | i) 250x10 mm |
| 216 | Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 217 | i) 125 mm |
| 218 | Providing & fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : |
| 219 | ii)150 mm diameter |
| 220 | W.C. pan with ISI marked white solid plastic seat and lid |
| 221 | Providing and fixing toilet paper holder : |
| 222 | C.P. Brass |
| 223 | Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by the Engineer-in-Charge. |
| 224 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 225 | Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 226 | Providing and fixing glazed vitreous China Oval wash basin of 560x410 mm size with M.S. or C.I. brackets painted white, C.P. brass chain with rubber plug, 32mm C.P. brass waste coupling of standard pattern, 32mm C.P. brass bottle trap and union, 32mm diameter C.P. pipes to wall flange etc. including cutting and making good the walls & floors wherever required, etc. complete in all respects inclusive of cost of all required fittings, fixtures, materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge : |
| 227 | White Colour |
| 228 | Providing and fixing C.P. Brass 32 mm size Bottle Trap of approved quality & make and as per directions of the Engineer-in-Charge. |
| 229 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete : |
| 230 | Semi Rigid Pipe : |
| 231 | 32 mm diameter |
| 232 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 233 | Providing & fixing 6mm thick, copper back finish, looking mirror of required size, made of float sheet glass of best quality & approved make, over 12mm thick marine board fixed to rawl plug with round head screws & washers including teakwood beading with melamine polish all around, complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. |
| 234 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 235 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 236 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 237 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 238 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 239 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 240 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 241 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 242 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 243 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 244 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 245 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 246 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 247 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 248 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 249 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 250 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 251 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 252 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 253 | Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete. |
| 254 | DISMANTLING AND DEMOLISHING |
| 255 | Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. |
| 256 | i) 1:3:6 or richer mix (i/c equivalent design mix) |
| 257 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge |
| 258 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 259 | Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge |
| 260 | Dismantling Steel work in single sections including dismembering and stacking within premises |
| 261 | i) R.S Joists |
| 262 | ii) Channels, angles, tees and flats etc |
| 263 | Dismantling Steel work in built up sections in angles, tees, flats channels etc. including all gusset plates, bolts nuts, cutting rivets welding etc. including dismembering and stacking within premises |
| 264 | Demolishing dry brick pitching in floors, drains etc. including stacking serviceable material and disposal of unserviceable material within premises |
| 265 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within premises |
| 266 | Carriage charge for disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, stacking, unloading to approved municipal dumping ground/unobjectionable place as/direction of Engg- in-Charge beyond IOCL Premises for all leads and including all lifts |
| 267 | iv) Distance > 5 km< 10 km |
| 268 | Taking out existing CC interlocking paver blocks from footpath central verge, including removal of rubbish etc., disposal of unserviceable material out of site at unobjectionable place and stacking serviceable material within premises as per direction of Engineer - in-Charge |
| 269 | Laying Corporation supplied interlocking paver blocks of any design /shape laid in required line,level,curvature,colour & pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as/ direction of Engineer-in-charge. |
| 270 | Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of: |
| 271 | i) G.S. Sheet/ Klippon galvalume sheet/ False ceiling panels |
| 272 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within premises |
| 273 | i) Of area 3 sq. metres and below |
| 274 | ii) Of area beyond 3 sq. metres |
| 275 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within premises. |
| 276 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within premises |
| 277 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within premises lead as directed by Engineer-in-charge. |
| 278 | Dismantling granite slabs / granite tiles / marble slab on wall, floor, pump Island etc., stacking of the serviceable materials and disposal of damaged materials as directed by IOCL including all charges etc. complete |
| 279 | ELECTRICAL WORKS |
| 280 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 281 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 282 | vi) 3 Core x 1.5 sq.mm Copper Cable FRLS |
| 283 | xvi) 3.5 Core x 25 sq. mm Aluminium Cable FRLS |
| 284 | xvii) 3.5 Core x 35 sq. mm Aluminium Cable FRLS |
| 285 | xix) 3.5 Core x 70 sq. mm Aluminium Cable FRLS |
| 286 | Re-laying corporation supplied cable complete as per specification |
| 287 | i) 1.5 sq.mm to 2.5 sq.mm XLPE |
| 288 | ii) 4 sq.mm to 10 sq.mm XLPE / AYFY |
| 289 | iii) 16 to 35 sq.mm XLPE / AYFY |
| 290 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 291 | vii) 3 Core x 2.5 sq. mm |
| 292 | vi) 3 Core x 1.5 sq. mm. |
| 293 | xvi) 3.5 Core x 25 sq. mm |
| 294 | xvii) 3.5 Core x 35 sq. mm |
| 295 | xix) 3.5 Core x 70 sq. mm |
| 296 | Supplying and installing of GI cable route marker with 100mm x 100mm x5mm thick GI Plate with inscription thereon, bolted/welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in ground as per drawing & direction of IndianOil Job includes painting with one coat of redoxide & finishing paint |
| 297 | Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen |
| 298 | Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil |
| 299 | i) 100mm x 25mm x 2mm |
| 300 | Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil |
| 301 | i) 150mm x 50mm x 2mm |
| 302 | ii) 200mm x 50mm x 2mm |
| 303 | Supply & fixing of weatherproof 125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL make including clamping arrangement, all complete as per specification & direction of Engineer In-charge. |
| 304 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 305 | ii) 32 x 6 mm G.I.strip |
| 306 | iii) 50 x 6 mm G.I. Strip |
| 307 | vi) 8 S.W.G. G.I. Wire (bare) |
| 308 | Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip) |
| 309 | Supplying and fixing of MV Lightining Arrestor horn gap type as required |
| 310 | Conducting testing of earthing pit for grid and pit resistance with required standard equipments, megger. Submission of 2 copies of the test report of the measured resistance, writing the resistance value on the earthing pit cover plate or on the display board. |
| 311 | ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 312 | iii) Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box |
| 313 | Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete. |
| 314 | i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 315 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 316 | i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire |
| 317 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 318 | iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire |
| 319 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. |
| 320 | ix) 6A, 3 Pin Modular Socket |
| 321 | x) 15 A 6 Pin Modular socket |
| 322 | xi) 2 Pin Telephone Modular Socket |
| 323 | Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs |
| 324 | vi) 8 way (4+24) TPN |
| 325 | Supply and fixing 4-pole MCCB of breaking capacity 16 KA in existing panel board. |
| 326 | ii) 63 Amp |
| 327 | MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings |
| 328 | i) 6A to 32A SP MCB |
| 329 | iii) 6A to 32A DP MCB |
| 330 | vi) 63A FP MCB |
| 331 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) |
| 332 | Supply and Installation of Flame Proof ESD Push Button |
| 333 | ENERGY METER Supply and fixing of 3-phase,4 Wire energy meter (KWH)-ordinary type |
| 334 | i) Direct on line type |
| 335 | Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 336 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 337 | i) 300 MM Sweep wall mounted fan |
| 338 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). |
| 339 | ii) 9\\" dia light duty, make Khaitan or equivalent |
| 340 | iii) 12\\" heavy duty, make GEC or equivalent |
| 341 | DISMANTLING Dismantling of following electrical fittings / fixtures with all leads and lifts. |
| 342 | i) Electrical cables of all sizes from under / above ground position |
| 343 | ii) DPS board all types with/ without stand |
| 344 | iii) 5 to 15A switches/MCBs/plugs |
| 345 | iv) 32/63/100A DP/TPN switches/ MCCBs /MCBs |
| 346 | v) Flourescent tube light fittings of all sizes |
| 347 | Phase wise measuring the electrical load, calculation of equipment wise load for balanced distribution in 3 phases. Disconnection & reconnecting cables in the feeder for balanced distribution of load in all 3phases,submission of report of final distributed electrical load. |
| 348 | Panel Board Stickering work |
| 349 | Preparation of single Line diagram - Electrical Layout |
| 350 | Supplying and laying 6 core single mode armoured optical fibre cable |
| 351 | Supply of Prefab CAT6 Ethernet un-armoured cable as per specification. |
| 352 | Supply & laying of Heavy Duty type, High compression strength, IP 67 rated (DWC) Double wall corrugated HDPE Conduits as per IS:14930/ IS:16205. Laying includes with GI pull wires inside the conduits & necessary ends to be filled with sealants, of all complete and as per drawing & specification. |
| 353 | i) 75 mm OD / 63 mm ID |
| 354 | Supply and Fixing of Discrete LED (Light Emitting Diode) Surface mounted Linear light fixture of following size, having IP 20 protection. class with Pressure Die cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), Ambient temp-0 to 45Deg Celsius, Driver efficiency > 85%, THD < 10%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level <60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 355 | i) 20 Watt (1200 mm) |
| 356 | Supply and Fixing of Indoor Surface mounted Discrete LED (Light Emitting Diode) Light fittings of 31 Watt, 600mm X 600mm suitable for False Ceiling ,having IP 20 protection class with Pressure Die cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, CCT (Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), Ambient temp- 0 to 45 deg celsius, Driver efficiency >85%, THD < 10%, Powerfactor>0.95, Surge protection-2 kV, Multistage isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard.Luminaire lumen ≥ 3640 lm. The driver shall be of constant volt and constant current type with internal surgeprotection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference /batch nos of LEDs and fittings for verification at site. The LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. and the fitting shall have suitable arrangement for fixing it in the False Ceiling. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 357 | i) 31 watt |
| 358 | PROVISION OF EARTHING |
| 359 | ii) Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specification & direction of Engineer-In-charge |
| 360 | Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 361 | Supply & fixing of 30mA RCCB of approved Make of following ratings: |
| 362 | i) 2 poles, 25A |
| 363 | iii) 4 poles, 25A |
| 364 | v) 4 poles, 63A |
| 365 | Supplying and fixing of MCB + ELCB (RCBO) with necessery inter connections on existing DB, Panel board. |
| 366 | i) 40 A 2 pole 100-300mA sensitivity |
| 367 | ii) 40A 4 pole 100-300mA sensitivity |
| 368 | Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. |
| 369 | i) Upto 32A SP MCB |
| 370 | ii) Upto 32A DP MCB |
| 371 | iii) Upto 32A TP MCB |
| 372 | iv) 63Amp 2 pole |
| 373 | v) 63Amp 4 pole |
| 374 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 375 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 376 | Supply and Fixing of Indoor Recess mounted Discrete LED (Light Emitting Diode) Light fittings, 600mm x 600mm suitable for False Ceiling, having IP 20 protection class with Pressure Die cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. High Efficiency Translucence(HET) diffuser.Colour Rendering Index CRI>80, Ambient temp- 0 to 45 Deg Celsius, Driver efficiency >85%, THD < 10%, Powerfactor > 0.95, Surge protection-2 KV, Multistage Isolated Constant Current- Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard.Luminaire lumen ≥ 3640 lm. The driver shall be of constant volt and constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79/ IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The LED light fitting shall be complete in all respects including LED, Driver, Electronic circuitory, Luminarie etc. and the fitting shall have suitable arrangement for fixing it in the False Ceiling. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 377 | i) 31 watt |
| 378 | Supply of Wall mounted Network Rack-minimum 10U 19\\" Rack for for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc in all complete as per specifications and direction of Engineer-in-charge |
| 379 | i) 300 MM Sweep wall mounted fan |
| 380 | Supply, Fixing of Photo electric smoke Detector low profile design, low current draw, wide operating voltage 9 to 33V DC, bicolour LED Detector, status indicator, automatic drift compensation programmable sensitivity, advanced maintenance features. |
| 381 | Supply, Fixing of Manual Call Point with Flip Abort Switch as per specification and direction of Engineer-in-charge. |
| 382 | Supply, Fixing of Conventional Hooter cum Strobe as per specification and direction of Engineer-in-charge. |
| 383 | Supply, Fixing, Testing and Commissioning of 2 Zone Conventional LCD Fire Alarm Control Panel with Non-expandable 2X16 LCD dis[play panel, resettable output for 4-wire connectivity beam sensor, Common sounder 24V DC 1A ,inbuilt 1 fire relay contact and 2 fault relay contacts 30V DC (a) Photo detector smoke Detector - 6 Nos, MCP-1 no, Hooter-1 No, (Rate for Supply & Laying of 2Cx1.5 sqmm cu Ar cable with 25mm Dia PVC conduits shall be paid separately) |
| 384 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 385 | ii) Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 386 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
| 387 | COCO, Standard drawing No. ENG/IOCL/PDIL-1. List of Componets are: (a) 1 No. MCCB (3P+N) of 160 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-150A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 160 A, Manually Operated Change over switch suitable for connection of Mains supply and 75 KVA DG Set /10 KW Solar system with required No. of MCCB (160 A, 35 KA, 3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 160A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/ Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 160/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 160 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4. (l) 12 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB 20 A, 10KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA,6 Nos DP MCB of 20A, 10 KA & 3 Nos DP MCB of 25 A, 10 KA in outgoing Feeder-3 (o) 3 Nos TP MCB of 16 A, 10 KA,3 Nos TP MCB of 20A, 10 KA & 6 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. |
| 388 | VRF AC FOR PANEL FLOOR AND CONTROL ROOM FLOOR |
| 389 | Supply of Top discharge type AI based Modular Variable refrigerant flow (VRF) system with Multiple Smart DC scroll type compressors (Advanced Flash Injection Compressor), Air cooled condenser with low noise Multi serration Fan, Dual Heatsink, having interconnected control wiring and refrigerant housed in compact housing duly powder coated of following capacities and matching air cooled condenser with copper tubes. Condenser shall be comprised with an anti-corrosive layer of epoxy acrylic and a hydrophilic layer of acrylic resin that disperses water and reinforces its corrosion-resistance.The units must have high COP/EER(3.5) at AHRI condition.Air conditioning system with Cooling facility suitable for 415 +/- 10% Volt, 50Hz Outdoor Units complete with Individual controllers, accessories, including full charge of refrigerant. |
| 390 | 32 HP SYSTEM (DVM S2 ) ONLY COOLING |
| 391 | 6 HP SYSTEM (DVM ECO ) ONLY COOLING (SIDE DISCHARGE) |
| 392 | Supply, erection, testing & commissioning of variable refrigerant flow 220-240v / 1ph / 50 Hz HI-WALL INDOOR UNIT comprising of coil, filter, fan. The unit shall be Mounted type and complete with all standard accessories. |
| 393 | HI-WALL UNIT ( 1.3 TR)-2 in 3 offices |
| 394 | Supply, erection, testing & commissioning of variable refrigerant flow 220-240v / 1ph / 50 Hz 4way CASSETTE INDOOR UNIT comprising of coil, filter, fan. The unit shall be Mounted type and complete with all standard accessories. |
| 395 | CASSETTE UNIT ( 2.0 TR)-control building floor |
| 396 | CASSETTE UNIT ( 4.0 TR)- Panel floor |
| 397 | Supply of Cordless Remote controller |
| 398 | Supply of Y joints / Distribution joints. |
| 399 | Installation, testing and commissioning of All Inverter VRV indoor and outdoor units along with controls, electricals, other required accessories including first charge of green refrigerant. Brick Pedestal or MS structure requitrd for ODU as per site condition will be in clients scope. |
| 400 | Combination of system (38HP) |
| 401 | Installation of VRF Indoor Unit (16) |
| 402 | Installation, testing and commissioning of Refrigeration Network (Refnet) joints per sets as required. |
| 403 | Supply, Installation and testing of interconnect refrigerant copper piping with fitting duly insulated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units of VRV as per specification. All exposed copper tubes with insulation shall be coated with UV protection cloth and UV paint .6.40 mm dia with 13mm thick nitrile rubber insulation9.53 mm dia with 13mm thick nitrile rubber insulation12.7 mm dia with 13mm thick nitrile rubber insulation15.86 mm dia with 13mm thick nitrile rubber insulation19.05 mm dia with 13 mm thick nitrile rubber insulation22.2 mm dia with 19 mm thick nitrile rubber insulation28.52 mm dia with 19 mm thick nitrile rubber insulation34.9 mm dia with 19 mm thick nitrile rubber insulation41.3 mm dia with 19 mm thick nitrile rubber insulation Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy