| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.1.32 |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire. Make Polycab,RR,Havells ,Finolex,KEI |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire Make Polycab,RR,Havells ,Finolex,KEI |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required2 x 4 sq. mm + 1 x 4 sq. mm earth wire Make Polycab,RR,Havells ,Finolex,KEI |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1.14.4 |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire Metre Make Polycab,RR,Havells ,Finolex,KEI |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm For Inverter Make Polycab,RR,Havells ,Finolex,KEI |
| 13 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1.18 |
| 14 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.1.19 |
| 15 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 1.24.6 |
| 17 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 18 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 20 | Supplying and fixing brass batten/ angle holder including connections etc. as required. |
| 21 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 22 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cableetc. as required. |
| 23 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.1.57 |
| 24 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1.53.2 |
| 25 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 26 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1.51 |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.1 6 way , Double door |
| 28 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12) double Door2.4.1 |
| 29 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.4.2 6 way (4 + 18), Double door |
| 30 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18) double Door 2.4.2 |
| 31 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'c' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing DB Single pole |
| 32 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 33 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 40 A as required. 2.12.1 |
| 34 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.2.24.2 For 6 way, Double door TPN MCBDB |
| 35 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 36 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 37 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 38 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 5.16 |
| 39 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 6.2 |
| 40 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 6.3 |
| 41 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 6.4 |
| 42 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as 11.6.2 40 mm dia |
| 43 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC |
| 44 | Supply ,Instalation, Testing and Commissioning of fire pump with 900 lpm at 35 mtr head Lubi / CRI |
| 45 | External Hydrant / Internal Hydrant.Supply , Instalation, Testing and Commissioning of Hydent Line with rises with B class MS pipe including, welding, primer, paint with all fitting such as MS socket, clamp fasteners, teflon tape . Make : Jindal ,Apollo, Surya, Swastik 80 mm dia |
| 46 | External Hydrant / Internal Hydrant.Supply , Instalation, Testing and Commissioning of Hydent Line with rises with B class MS pipe including, welding, primer, paint with all fitting such as MS socket, clamp fasteners, teflon tape . Make : Jindal ,Apollo, Surya, Swastik 25 mm dia |
| 47 | Supply , Instalation, Testing and Commissioning of 25mm dia 40 mtr long swing type 180 degree adjustable with complete drum set firstaid hose reel with nosel (brass nosel) with complete fitting. Make : Life Line safety , safe pro ,omex , Masc I,etc |
| 48 | Supply , Instalation, Testing and Commissioning of (SS)single head landing wal complete set (63mtr dia) Make : agni, index ,omex or LifeLinesafety, Masc I |
| 49 | Supply , Instalation, Testing and Commissioning of Set of RRL pipe for the use of landing wall including with mail femail coupling : Life Safety safe ex index (A set of 1 pipe with the length of 15 mtr |
| 50 | Supply and Fixing Of 63 mm dia Gun metal Branch Pipe with Nosel |
| 51 | Supply , Instalation, Testing and Commissioning of Butterfly Valve 80 mm dia |
| 52 | Providing , Instalation, Testing and Commissioning of Non Return Valve (NRV) 80 mm dia |
| 53 | Suppling and fixing of Firebrigade Inlet Two Way(Ms) |
| 54 | Providing and Fixing Of Pressure Switch |
| 55 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 17.1.9.1 4 Zone |
| 56 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.manual call point |
| 57 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 58 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 59 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 60 | S&F of 320 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 380 |
| 61 | Supply and laying of aluminium conductor PVC insulated un armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over acushion of 75 mm.cable shall be properly connected with the earth conductor by clamps etc.16 sq. mm 2 core for |
| 62 | Supply and laying of aluminium conductor PVC insulated un armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over acushion of 75 mm.cable shall be properly connected with the earth conductor by clamps etc.150 sq. mm 4core |
| 63 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. 400 Amp. MCCB-1 Nos. Outgoing (e) 100 Amp.MCCB-3Nos. & 63 Amp.MCCB-2Nos.(i) Cat. A Pannel Cubicle Type each - -(ii) Cat. B. Pannel Cubicle Type each 199172.00 3322.00 |
| 64 | Supply and fixing of cross clamp of required size fabricated from 50mm x 12mm M.S. flat complete with fan hook including painting etc. complete in all respect. |
| 65 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect.1417 |
| 66 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. Cat AA |
| 67 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. Cat AA |
| 68 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 69 | Supply and fixing of C02 type fire extinguisher 4.5 kg.capacity (ISI Marked IS : 2878 & TAC approved)complete with initial charge and wall bracket, along withsupply of all materials and labour for proper completionof work. |
| 70 | Orient electric Self Ballasted LED Lamps for General Lighting Service 18 Watts Orient electricR (orient electric best quality 18W bulb)Product id: 5116877-42771323302 |
| 71 | Supplying and Fixing of exhaust fans of 300 mm sweep of aproved brand and manufacture |
| 72 | crompton Stainless steel Wall lamp, 9 Watt cromptonR (LUPDN-10-CDL) Product Details 2,300.00 Product id: 5116877-7562720530 |
| 73 | 3DLINK Yes RJ45 Yes CAT 6 Information outlet 3DLINK (Cat6 Information Outlet Quad Port) Product id: 5116877-43912923767 |
| 74 | D-Link 24 Ports Web Managed PoE+ Layer 2 Access Switch D-LinkR (L2 ACCESS SWITCH DGS-1210-28MP)Product Details Product id: 5116877-19754684024 |
| 75 | 6 U Rack DATARACK 6U Rack Enclosures Networking/Server Rack DATARACKR (DATARACK-DRWM-06-08) Product Details Product id:5116877-62779329122 Please Enable Macros to View BoQ information |