| 1 | SCH 'A' PART-I: BUILDING/STRUCTURESNote: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only |
| 2 | Design and Construction of Multi-storeyed ORs Married Accommodation (S+16) Floors (01 Tower) for 64 DUs including stilt Parking at Colaba, Mumbai including all internal services and external services as defined in Annexure-I to XIV (excluding Sch 'A' Part II to VIII), complete as detailed in scope of work and other documents of tender, complete all as specified and directed |
| 3 | NOTE: Schedule ‘A’ Part-II to VII items which are Prepriced by MES, Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 4 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation & Earthwork) |
| 5 | Total amount of Sch ‘A’ Part III (Road, Culverts and Hard Standing ) |
| 6 | Total amount of Sch ‘A’ Part IV (Area Drainage) |
| 7 | Total amount of Sch 'A' Part-V (Sewage Disposal) |
| 8 | Total amount of Sch ‘A’ Part VI (Chain Link Fencing) |
| 9 | Total amount of Sch ‘A’ Part VII (External Electric Supply) |
| 10 | SCHEDULE 'A' PART-VIII (MISC B/R AND E/M WORKS )Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 6 signifies this fact only. |
| 11 | M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm in width or girth and applying two coat of antocorrosive paint over red oxide primer complete all as directed and specified. |
| 12 | S&F Galvanised ,concertina coil of 610mm dia made of 0.5 mm thiclk 19mm wide strip and 2.59 mm dia high tensile wire 125 nos of clips having 50 Nos of circle and covering 6 running mtr and 5 clips per spiral using a center core of high tensile wire around which a tape of rezor sharp barbes machine crimped etc all as approved and directed. |
| 13 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required |
| 14 | M&L Plain Cement Concrete, (1:3:6), type C-2 using 40mm graded stone aggregate as in bed to drain pipe of 600 mm bore including packing under and haunching against the sides of pipes after they are laid and tested all as speciied and directed for following sizes of RCC drain pipes. |
| 15 | M&L for preparing bituminous surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed |
| 16 | Supply installation, testing and commissioning of Transformer, step-down, 11/0.433 KV complete, 50 HZ, indoor, copper wound of capacity 315 KVA (at New Sub stn), Level-3 (Reaffirmed as level-2) with following specifications:-(a) No load voltage ratio - 11KV/0.433 KV(b) Type of cooling - ONAN(c) Frequency - 50 HZ(d) Vector group - DYN 11(e) Two earthing terminals for body earthing and two additional for neutral.(f) Oil level gauge indicating oil level with minimum and maximum indication(g) First fill of oil upto level including conservator tank with fresh new oil(h) Lifting lugs, rollers and MS terminals Box on both HT and LT side.(j) Rating and terminal marking plates.(k) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects(l) Drain cum sampling valve (3/4\\" nominal size thread) preferably steel with plug(m) Thermometer pocket(n) Oil filling hole (1-1/4\\" Nominal size thread) with cover (transformer with conservator) Please Enable Macros to View BoQ information |
| 17 | Supply installation, testing and commissioning of Transformer, step-down, 11/0.433 KV complete, 50 HZ, indoor, copper wound of capacity 315 KVA (at New Sub stn), Level-3 (Reaffirmed as level-2) with following specifications:-(a) No load voltage ratio - 11KV/0.433 KV(b) Type of cooling - ONAN(c) Frequency - 50 HZ(d) Vector group - DYN 11(e) Two earthing terminals for body earthing and two additional for neutral.(f) Oil level gauge indicating oil level with minimum and maximum indication(g) First fill of oil upto level including conservator tank with fresh new oil(h) Lifting lugs, rollers and MS terminals Box on both HT and LT side.(j) Rating and terminal marking plates.(k) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects(l) Drain cum sampling valve (3/4\\" nominal size thread) preferably steel with plug(m) Thermometer pocket(n) Oil filling hole (1-1/4\\" Nominal size thread) with cover (transformer with conservator) Please Enable Macros to View BoQ information |