| 1 | Part-A (Sanctioned Schedule items) Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with modular type switch,modular plate and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /HPL /KEI/Polycab Conduit Make - ISI Marked Anchor/High Power /AKG/Equivalent make of required specification to be approved by the Engineer In charge (Group ‘A’) |
| 2 | Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/KEI/Plaza/polycab Equivalent make of required specification to be approved by the Engineer In charge )i. 2x1.5 +1x1.5 Sq mm |
| 3 | i. 2x2.5+ 1x2.5 Sq mm |
| 4 | iv. 4x6 +2x6 Sq mm |
| 5 | Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia |
| 6 | Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 7 | Supply and Fixing following ratings, four pole, 415 volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. 63 Amp ratings (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 8 | b.63 Amp 240 volt Double Pole Isolator. |
| 9 | Supply and fixing of following size/module, GI box along with modular base and cover plate for modular switches in recess etc. as reqd A. 1 or 2 Module |
| 10 | B.6 Module |
| 11 | C.4 Module |
| 12 | Supply & fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Anchor/Havells /HPL/Great White Equivalent make of required specification to be approved by the Engineer In charge) i.5/6 Amp Switch |
| 13 | ii.15/16 Amp Switch |
| 14 | iii.3 pin 5/6 Amp Socket |
| 15 | iv.6 pin 5/6 Amp Socket |
| 16 | Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 17 | Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / C&S/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 18 | Supplying and fixing following ways horizontal type three pole , and Neutral, sheet steel MCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.8 way(4+24), Double door Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge |
| 19 | Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T Equivalent make of required specification to be approved by the Engineer In charge)1 run of cable |
| 20 | Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (Wire Make ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge) i.1x1.5 sqmm |
| 21 | v.2x6 sqmm |
| 22 | Part-B (Non Schedule items) Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/ Syska/Bajaj/ Greatwhite/ Philips/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) 20 to 24 Watt LED recessed/surface mounting 6500 K, 240 Volts Slim Panel down light fittings/luminaries round (225x225)mm to (300x300)mm Dimensions. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) |
| 23 | Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient .(Make: Havells /Anchor /Crompton/USHA Equivalent make of required specification to be approved by the Engineer In charge) |
| 24 | Supply /Installation testing and commissioning of 450 mm sweep wall mounted fan including the electronic regulators and connection with testing and commissioning etc complete Job BEE 1 to 3 star rated energy efficient. Make: (Anchor /Bajaj /Cromton/ Havells Equivalent make of required specification to be approved by the Engineer In charge ) |
| 25 | Supply & installation of CAT 6 2 module toll less information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required.(Make Legrand/Delton/Havells/HPL/Anchor) |
| 26 | Supplying and fixing following ways horizontal type MCB Board 230V on surface/in recess complete interconnections including powder painted etc. as required (But without MCB/SPN.) i.4 way Encloser (Make :-Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge ) |
| 27 | Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge) Please Enable Macros to View BoQ information |