| 1 | Repair and repainting of exterior walls of conference centre and auditorium building at IITG Campus |
| 2 | Repair and repainting of exterior walls of new SAC building at IITG Campus. Name of Work - Repair and Repainting Exterior Walls of Conference Centre and Auditorium buliding in IITG Campus Item No Description of Item Unit Qty Rate (₹) Amount (₹) Conference Centre |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within the campius lead as per direction of Engineer -in - charge. Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) cum 13.5 0.0 |
| 4 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-ill) derived from natural sources : 10 AAC block 40 mm nominal size derived from natural sources) cum 8.1 0.0 |
| 6 | Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum 13.5 0.0 |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 8 | Providing and laying water proofing treatment in wall portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 9 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 10 | Cutting the existing crack in a V Shape groove cleaning the the same with proper means of application of one coat of EpoxyBonding agent followed by application of Sikha214 Non shrinkage powder over the entire crack area and let dry. Finally plaster the surface whenever required. |
| 11 | (a) Surface preparation: preparing the surface by chipping & cleaning the surface with wire brush and free from all contamination. Wash it thoroughly with high jet water. |
| 12 | (b) providing and fixing 100 mm width multi seal tapes over the preparing surface. |
| 13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete |
| 14 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) sqm 4500.0 0.0 |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade involving primer coat with ordinary paint of approved brand and manufacture sqm 800.0 0.0 |
| 16 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter RM 40.0 0.0 |
| 17 | Providing of Fixing PVC Clamp for the rainater/sever PVC pipe for necessar inlcding ss screw for fixing and fitting as per direction of Engineer Incharge |
| 18 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design In 75x75 mm deep chase metre 163.0 0.0 |
| 19 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using Gl slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm Gl adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge 12.5 mm thick square edge PVC Tile of size 595x595 mm, made of Poly vinyl chloride, manufactured from as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. sqm 1800.0 0.0 |
| 20 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Total Amount Part A = 0.0 Auditorium Damproofing in wall |
| 21 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 22 | Providing and laying water proofing treatment in wall portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 23 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 24 | Cutting the existing crack in a V Shape groove cleaning the the same with proper means of application of one coat of EpoxyBonding agent followed by application of Sikha214 Non shrinkage powder over the entire crack area and let dry. Finally plaster the surface whenever required. |
| 25 | (a) Surface preparation: preparing the surface by chipping & cleaning the surface with wire brush and free from all contamination. Wash it thoroughly with high jet water. |
| 26 | (b) providing and fixing 100 mm width multi seal tapes over the preparing surface. |
| 27 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 28 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 30 | Two or more coats on new work over an under coat of suitable shade involving primer coat with ordinary paint of approved brand and manufacture |
| 31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter RM 35.0 0.0 |
| 32 | Providing of Fixing PVC Clamp for the rainater/sever PVC pipe for necessar inlcding ss screw for fixing and fitting as per direction of Engineer Incharge |
| 33 | Providing and fixing 1st quality ceramic exterior wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Total Amount Part B= 0.0 Total Part A+B= 0.0 Name of work: Repair and repainting of external walls of new SAC building at IITG Campus. Item No. Description of item Unit Qty Rate (₹) Amount (₹) |
| 35 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (a) In cement mortar Cum 6.48 0.0 |
| 36 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin- charge. Damproofing |
| 37 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 38 | Providing and laying water proofing treatment in wall portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 39 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 40 | Cutting the existing crack in a V Shape groove cleaning the the same with proper means of application of one coat of EpoxyBonding agent followed by application of Sikha214 Non shrinkage powder over the entire crack area and let dry. Finally plaster the surface whenever required. Expansion Joint |
| 41 | Expansion Joints Treatment with Sikadur Combiflex SystemStep-1. Removal of extra topping between the expansion joint area: Preparation of Expansion Joint edge by grinding and removal of all loose particles, dirt, dust etc to make the surface clean including scaffolding , tools tackles etc all complete Step-2. Providing and Mixing of epoxy adhesive sikadur 31 C (2:1) by mechanical mixture and apply on the 50 mm surface of both sides as per the manufacturer specification including tools, labour, machines etc all completeStep-3. Providing and Fixing of Hypalon based Sikadur Combiflex SG strip (200 mm width x 2mm thickness on the expansion joint as per the manufacturer specification including tools, labour, machines scaffoldings etc all completeStep-4. Finally Providing and Mixing of epoxy adhesive sikadur 31 C (2:1) by mechanical mixture and apply on the 50 mm surface of both sides as per the manufacturer specification including tools, labour, machines etc all complete as a protective coating Water proofing treatment work |
| 42 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. For the purpose of measurement the entire treated surface will be measured. |
| 43 | Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12 mm nominal size) Cum 13.5 0.0 |
| 44 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : (a) 1:4 (1 cement: 4 fine sand) Sqm 740.0 0.0 |
| 45 | Providing and fixing sheet covering over expansion joints with iron screws as per design. (a) Aluminium fluted strips 2.00 mm thick and 200 mm wide. Rm 61.0 0.0 |
| 46 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.l. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.l. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.l. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) Sqm 64.0 0.0 |
| 47 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (a) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre Sqm 200.0 0.0 |
| 48 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |
| 49 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 50 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 51 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) Sqm 4230.0 0.0 |
| 52 | Applying priming coat: (a) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works Sqm 170.0 0.0 |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (a) One or more coats on old work Sqm 490.0 0.0 |
| 54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (a) 110 mm diameter Rm 189.0 0.0 |
| 55 | Providing of Fixing PVC Clamp for the rainater/sever PVC pipe for necessar inlcding ss screw for fixing and fitting as per direction of Engineer Incharge |
| 56 | Providing and fixing of Armstrong Knauf Mineral Fibre tile 600x600x12 mm as per Direction of Engineer in Charge. |
| 57 | a) Removal of old glasses from the damaged portion including scaffolding etc. as required complete and disposal of debris as directed by engineer in charge b) Providing & fixing of 6mm reflective toughened glass of approved colour including necessary cleat, bracelets, silicon sealant, all fittings, additional subframe for structural etc. complete as directed bu engineer in charge Total Amount ₹ = 0.0 Please Enable Macros to View BoQ information |