Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKSingle under reamed 450mm Dia pile foundation upto a depth of 8m with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes and cost of M.S. rod/Tor steel and labour sundries T&P etc complete and as per direction of engineer -in- charge. (A) 12 Mtr Depth Pile |
| 2 | (B). 14Mtr Depth Pile |
| 3 | Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge. |
| 4 | Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge. |
| 5 | C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 6 | Brick work with Fly Ash bricks of size 25cmx12cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:4) in foundation and plinth including all charges. |
| 7 | Providing, lifting, hoisting and laying Reinforced Cement Concrete of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair case, jali , shelves and slab etc as per approved designs and drawings having a minimum compressive strength ( in work test) 20N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.(A). Coloumn Footing |
| 8 | (B). Coloumn Ground Floor |
| 9 | (C). Coloumn First Floor |
| 10 | (D). Coloumn Second Floor |
| 11 | (E). Plinth Bend |
| 12 | (F). LintelGround Floor |
| 13 | (G). LintelFirst Floor |
| 14 | (H). LintelSecond Floor |
| 15 | (I). Roof BeamGround Floor |
| 16 | (J). Roof BeamFirst Floor |
| 17 | (K). Roof BeamSecond Floor |
| 18 | (L). ChajjaGround Floor |
| 19 | (M). ChajjaFirst Floor |
| 20 | (N). ChajjaSecond Floor |
| 21 | (O). Roof SlabGround Floor |
| 22 | (P). Roof SlabFirst Floor |
| 23 | (Q). Roof SlabSecond Floor |
| 24 | (R). StaircaseGround Floor |
| 25 | (S). StaicaseFirst Floor |
| 26 | (T). Wall Ground Floor |
| 27 | (U). FinnGround Floor |
| 28 | (V). FinnFirst Floor |
| 29 | Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only.(A). Ground Floor |
| 30 | (B). First Floor |
| 31 | (C). Second Floor |
| 32 | Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:6) in superstructure per cum.(A). Ground Floor |
| 33 | (B). First Floor |
| 34 | (C). Second Floor |
| 35 | Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:4) in superstructure per cum.(A). Ground Floor |
| 36 | (B). First Floor |
| 37 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.(A). Ground Floor |
| 38 | (B). First Floor |
| 39 | (C). Second Floor |
| 40 | 16mm thick cement plaster (1:6) on brick work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm.(A). Ground Floor |
| 41 | (B). First Floor |
| 42 | (C) . Second Floor |
| 43 | 6mm thick cement plaster (1:4) onRCC concrete drain work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm.(A). Ground Floor |
| 44 | (B). First Floor |
| 45 | ( C). Second Floor |
| 46 | Wall painting 2 coats with weather coat over a coat of primer to inside and out side smooth surface with all cost of labour, T&P material etc complete.(A). Ground Floor |
| 47 | (B). First Floor |
| 48 | ( C). Second Floor |
| 49 | Wall painting 2 coats with Plastic emulsion paint of approved shade over a coat of primer on new work to give an even shade with all cost of labour, T&P material etc complete.(A). Ground Floor |
| 50 | (B). First Floor |
| 51 | ( C). Second Floor |
| 52 | M.S. Grill gate made out of M.S. flat conforming to IS 2062/20006 painted with red oxide primer as pe the design approved. |
| 53 | Painting two coats with approved synthetic enamel paints of Asian / Berger/Dulox make and of approved colour, shade to new Iron including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use.Grills |
| 54 | Dressed and Seasoned Sal wood work for door frames.Ground Floor |
| 55 | Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete.Ground Floor |
| 56 | Supplying, fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitings and fixtures. |
| 57 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures. |
| 58 | Fixing vitrified tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete. (600 X 600 ) mm Kajaria/Somany(A). Ground Floor |
| 59 | (B). First Floor |
| 60 | ( C). Second Floor |
| 61 | Fixing vetrified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete.(A). Ground Floor |
| 62 | (B). First Floor |
| 63 | Fixing of ceramic floor tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete.(400 x400) mm Kajaria/ Somany (A). Ground Floor |
| 64 | (B). First Floor |
| 65 | Fixing Ceramic wall tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete.(A). Ground Floor |
| 66 | (B). First Floor |
| 67 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips complete all as per direction of Engineer-in-Charge. (A). First Floor |
| 68 | (B). Second Floor |
| 69 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. |
| 70 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 71 | PH WORK (INTERNAL) PVC ASTM Pipes and fittings (Riser & Down) Non-Concealed(A). 40 mm dia CPVC Pipe (Rise Up) |
| 72 | (B). 25 mm dia CPVC pipe ( Down Pipe) |
| 73 | PVC ASTM Pipes and fittings (Riser & Down) Concealed20 mm dia CPVC Pipe |
| 74 | Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(A). 15 mm dia CP 2 way Bib Cock (Short body) or Health Processor ( 3.2.14) |
| 75 | (B). 15 mm dia CP Bib cock ( Long Body) |
| 76 | ( C). 15 mm dia CP Angle stop cock |
| 77 | (D). 15 mm dia Conc. Stop cock. |
| 78 | (E ). 15 mm dia C.P. Pillar cock |
| 79 | (F). 15 mm dia C.P. Shower with arm |
| 80 | (G). 600 mm long CP Towel rail |
| 81 | (H). CP Soap holder |
| 82 | (I). 15 mm dia C.P. Towel Ring |
| 83 | (J). 600 mm long C.P. Glass shelf with C.P frame |
| 84 | (K). 110 mm dia C.P. waste |
| 85 | (L). 40mm dia GM FW valve |
| 86 | Supplying, Fittings & Fixing with all labour, T&P as per specification, the following flexible PVC connection pipes and waste pipe making connection with pillar cock, cistern. Wash hand basin at all height and all floors with all jointing materials etc. complete as per direction of the Engineer -in- charge.(A). 450-600 mm long 15mm dia PVC connection pipe. |
| 87 | (B). 40 mm dia flexible PVC waste pipe 1 mtr each. |
| 88 | Supplying, Fittings & Fixing of 10 Ltr. Capacity low level P.V.C cistern white colour, to wall at all floors and at all height with all accessories etc. complete in all respect as per direction of the Engineer -in- charge. |
| 89 | Supplying, Fittings & Fixing of following sizes of porcelain wash hand basin confirming to relevant IS specification of Nycer/ Cera/ Parryware make to the brick / concrete wall etc. complete as per direction of the Engineer in charge.(a) Standard ( 550x400mm) size basin |
| 90 | Porcelain Flat back stall type magnum Urinal with IS specification Including all cost. |
| 91 | Supplying , fitting and fixing the standard size of European pattern porcelain wash down water closet confirming to relevant IS specification of Nycer/ Cera / Parryware make having 'S' or 'P' trap etc with all required materials, labour T&P etc. complete as per direction of the Engineer in charge. |
| 92 | Supplying ,fitting and fixing with all labour and T & P 4mm thick bevelled edge sheet glass mirror (508mmx406) of relevant IS specification to the brick concrete wall with full sheet hard board and CP down shaped screw on wooden /PVC plug etc. complete as per direction of the Engineer in charge. |
| 93 | Supplying all labour T & P etc for cutting holes in brick masonry wall/ RCC work for passing of GI /pvc Pipes of 15 mm to 50 mm dia and making good to the damages with C.M. (1:4) as per direction of the Engineer in charge. |
| 94 | Supplying, fitting & fixing of ISI marked PVC,CLASS-B(SWR) pipes with all materials, labour & T&P on concrete / Brick walls and grounds with nails, bobbins and wooden plugs as required including , scaffolding with proper plumbing fittings for exposed pipes complete in all respect as per direction of the Engineer in charge.110mm dia PVC pipes Ground Floor |
| 95 | Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVC pipes (on concrete / Brick walls and grounds) with all materials labour T&P including cutting of the walls, with supply of nails, bobbins and wooden plugs as required including scaffolding etc. complete in all respect as per direction of the Engineer in charge.(A). 110 mm dia Single Junction with door |
| 96 | (B). 110 mm dia plain Door Bend |
| 97 | ( C). 110 mm dia 'P' Trap |
| 98 | (D). 110 mm dia Off set |
| 99 | (E ). 110 mm dia Cowl |
| 100 | (F). 75 mm dia Single Junction with door |
| 101 | (G). 75 mm dia elbow |
| 102 | Fixing rational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts , fixing ball valve etc., including hoisting upto a height of 5 meters above ground level and palcing the tank to the required position etc all complete asper specification and direction of the Engineer In charge. i.e 1000 ltr capacity cylinderical vertical water storage tank with lid. |
| 103 | 110mm dia PVC pipes including fitting and fixing with all cost as per direction of E.I.C.(A). Rain Water |
| 104 | (B). For Septic tank,soak pit & IC connection |
| 105 | PH WORK (EXTERNAL)Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge.(A). Within 1.5 mtr lift |
| 106 | (B). Beyond 1.50 mt lift |
| 107 | Filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge. |
| 108 | C.C (1:3:6) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 109 | Cement concrete M-25 with 12mm size CBHG chips including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 110 | 1st class Fly ash .Brick work in cement mortar (1:3) in Foundation and Plinth including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 111 | 12mm thick C.P.(1:3) in F&P including punning , conveyance , royalty & taxes etc complete to work site as per specification approved by the department & direction of E.I.C. |
| 112 | 12mm thick C.P.(1:3) in F&P including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 113 | Rigid and smooth centering and shuttering for RCC work including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 114 | Cement, concrete M25 for RCC work using 12mm size H.G.chips including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 115 | M.S.reinforcement for RCC work including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 116 | Fitting fixing of 110mm O.D.P.V.C.SWR vent pipe including all cost. |
| 117 | Fitting fixing of PVC cowl including all cost. |
| 118 | Filling F&P with excavated materials with well watered and rammed out side of Septic tank including all cost as per direction of E.I.C.. |
| 119 | Construction of Soak way pit of 1.20m dia x 2.40m deepEarth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge. |
| 120 | Filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge. |
| 121 | Cement concrete (1:2:4) with 12mm size CBHG chips including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 122 | 1st class Fly ash .Brick work in cement mortar (1:4) in F&P including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 123 | 1st class Fly ash .Brick work in dry laid in F&P including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 124 | 12mm thick C.P.(1:6) in F&P including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 125 | Filling khoa including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 126 | 12mm thick C.P.(1:3) in F&P including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 127 | Rigid and smooth centering and shuttering for RCC work including all cost as per direction of E.I.C. |
| 128 | Cement, concrete M20 for RCC work using 12mm size H.G.chips including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 129 | M.S.reinforcement for RCC work with cutting , bending & typical including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C. |
| 130 | Construction of 0.76 m x 0.76 m x 0.45 m size inspection chamber with specification as per direction of E.I.C. |
| 131 | INTERNAL & External Electrification and Allied workSub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.(A). Group - A |
| 132 | (B). Group-B |
| 133 | ( C). Group - C |
| 134 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 135 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 136 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 137 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION. |
| 138 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5). |
| 139 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5). |
| 140 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIV Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5). |
| 141 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit (2X6+1X4). |
| 142 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(4X6+2X4). |
| 143 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(4X10+2X6). |
| 144 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 145 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 146 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 147 | Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 148 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator). |
| 149 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W (2'x2' 595x595x70mm) and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years. |
| 150 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years. |
| 151 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 152 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years. |
| 153 | Supplying and fixing of Energy efficient surface /recess mounted round shape 6 W LED luminaire of dimension of consists of white powder coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution and lumen output of 660 lumens, CRI not less than 80,CCT of 6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years. |
| 154 | Supply, Installation Testing and Commissioning of IP20 LED strip with a nominal system lumen output of 1600 lm /m with system efficacy of 102lm/W SDCM<=3 Ra >=80; R9>= 0 . The luminaire shall have a rated system lifetime of 30,000 hours. The luminaire shall have a color temperature of 4000K and CRI>80with No of LED 120 Nos . luminaire is to operate on 24VDC.with working temperature rage of upto 35degC ambient. Luminaire must be supplied along with all the accessories such as driver, moutning tracks/ clips, end caps, diffuser, strip connectors etc as applicable. Similar to PhilipsFlexCove G5 LS170S G2 Basic (5m Roll) + Accesories With all accessories.(Make:Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years. |
| 155 | Supply, Installation Testing and Commissioning of 24v DC Diver 100W IP20 driver With all accessories. |
| 156 | Supplying, installation, testing and commssioning of 400 mm sweep white/milky colour WALL fan Make-Crompton /Havells/Usha ) i as required as per direction of Engg.-in-Charge,Replacement Warranty will be 2 years.. |
| 157 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 158 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision). |
| 159 | BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 yearsa. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years. |
| 160 | Supplying and fixing 6 amps to 32 amps 10KA C series rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 161 | Supplying and fixing 40Amps 4P 415 volts, MCB 10KA C series Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 162 | Supplying and fixing 40 Amps rating,4P RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 163 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 year. |
| 164 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 165 | (Earthing) INSTALLATIONSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 166 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 167 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 168 | CABLING AND END TERMINATION MAIN AREA1. Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. (A)..3.5core x 185 sq mm |
| 169 | (B). 3.5core x 95 sq mm |
| 170 | ( C). 3.5core x 35 sq mm |
| 171 | (D). 4core x 16 sq mm |
| 172 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 173 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 174 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 175 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 176 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 177 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.(A). 3.5 core x185 sq mm |
| 178 | (B). 3.5 core x95 sq mm |
| 179 | ( C). 3.5 core x35 sq mm |
| 180 | (D). 4 core x16sq mm |
| 181 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia. |
| 182 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia. |
| 183 | PANELS S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20x10mm separate aluminium earth busbar is to be given.All the feeders shall have ON/OFF/TRIP indication.Mandatory provision of cable alley is to be given. |
| 184 | UPS SYSTEMSupply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 185 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 186 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 187 | EXTERNAL AREA LIGHTINGS/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 188 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 189 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 190 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 191 | Supplying ,installation & fixing of 10-11W(BOLLARD), High efficient LED with extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire efficacy ≥ (90 lm/W). Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 192 | Supply ,Installation testing commissioning of Asthetically designed 40-45W(post top), High efficient LED comprises with spun aluminium top cover ,dicast aluminium heatsink,frosted polycarbonate diffuser with dicast mounting base arm.CRI>70, IP65, Ambient temp-0 to 45DegC, Driver efficiency>85%, CCT-4000/5700K,THD<10%,Powerfactor>0.95, Surge protection-4 kV internal and 10KV external, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 4600 lumens (115 lm/W). Similar to Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)l make having warrantied for a period of 5 years . The luminaire to be installed in 6 mtr long GI hot dip galvanized pole with anti corroson,,uv rays stabilized,metal post with covered by resin of Valmount/BAJAJ/RR ISPAT/UTKASH/VAKRANGEE make equievalant make with proper model complete with SA bracket internal JB with 4 way connector and MCB as per the pole drawing and direction of EIC against which inspection mat take place. It should be installed after making proper size RCC foundation by considering RCC foundation by using M20 grade RCC & Fe 415 grade reinforcement and fixing the 4 nos. En 8 grade J type fdn bolts in the foundation. The luminaire needs to be wired with 3 c 1 sq mm wire from JB as per the direction of Engg-in -charge. |
| 193 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge |
| 194 | Supply and laying of 6SWG GI wire on surface or recess as per the direction of Engineer-in-charge |
| 195 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 196 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/RR Kabel/Finolex/Gloster/Havells etc. |
| 197 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 32 mm. |
| 198 | LIGHTNING PROTECTION :-Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB. |
| 199 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB. |
| 200 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB. |
| 201 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB. |
| 202 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB. |
| 203 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB. |
| 204 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 205 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB. |
| 206 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB. |
| 207 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB. |
| 208 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 209 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB. |
| 210 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB. |
| 211 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB. |
| 212 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB. |
| 213 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB. |
| 214 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB. |
| 215 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB. |
| 216 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB. |
| 217 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 218 | 58.5 KVA DGSupply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of prime rated 58.5KVA ( Make -Kirloskar / Jakson/Mahindra/TMTL/CAPTIVA/Sterling) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years . |
| 219 | SOLAR 10KWSupply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make TATA /LUMINOUS /WAREE/ADANI/panasonic The entire SOLAR system should be Replacement Warranty will be 5 years Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail