| 1 | Earth work excavation in foundation in all kinds of soil within 50 m initial lead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm and laying in layers not exceeding 0.3 m in depth & as per the direction of the Engineer-in-charge. (Dispensary Building) |
| 2 | D type Qtr ( Ground Floor) |
| 3 | E type Qtr ( Ground Floor) |
| 4 | Compound Wall |
| 5 | Supplying, filling in foundation and plinth with sand in layers not exceeding 23cum (9inch) thick including watering and ramming with the cost, conveyance, royality, taxes of all materials, labour, T and P required for the Work etc. complete as per specification and direction of the Engineer-in-Charge.(Dispensary Building) |
| 6 | D type Qtr ( Ground Floor) |
| 7 | E type Qtr ( Ground Floor) |
| 8 | Compound Wall |
| 9 | Cement Concrete of proportion (1:3:6) in foundation and floors using 4cm (3/2) size clean hard black broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6) thick to the required level ramming watering and curring etc. complete including cost and conveyance of all materials with all taxes and royalities and all labour with T and P required for the work etc. complete including dewatering if required as per specification and direction of the Engineer-in-Charge.(Dispensary Building) |
| 10 | D type Qtr ( Ground Floor) |
| 11 | E type Qtr ( Ground Floor) |
| 12 | Compound Wall |
| 13 | Brick work with Fly Ash Bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than 75 Kg/Cm2 with dimensional tolerance +/- 8 percent in cement mortar (1:6) in Foundation & Plinth etc. complete as per specification and direction of the Engineer-in-Charge.(Dispensary Building) |
| 14 | D type Qtr ( Ground Floor) |
| 15 | E type Qtr ( Ground Floor) |
| 16 | Compound Wall |
| 17 | Brick work with Fly Ash Bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than 75 Kg/Cm2 with dimensional tolerance +/- 8 percent in cement mortar (1:6) in Superstructure etc. complete as per specification and direction of the Engineer-in-Charge.( Dispensary Building) |
| 18 | D type Qtr ( Ground Floor) |
| 19 | E type Qtr ( Ground Floor) |
| 20 | Compound Wall |
| 21 | Cement concrete (1:2:4) using 12mm hard granite crusher broken metal including all cost , carriage, royality, taxes, and all labour involved for completion of item of work as per the direction of Engineer- in - charge. (Dispensary Building) |
| 22 | D type Qtr ( Ground Floor) |
| 23 | E type Qtr ( Ground Floor) |
| 24 | Compound Wall |
| 25 | Providing and laying RCC M-20 grade using 20 mm and downgraded size hard black broken granite stone chips of approved quality and from approved quarry including hoisting, lowering and laying concerete and compacting by using vibrators watering and curring for 4 weeks centering and shuttering and finishing the exposed surface smooth providing grooves of beads where necessary including cost, conveyance, royalities and taxes of all material and labour required for the work etc. complete excluding cost and conveyance of M.S. Rod or steel and binding wires of 18 to 20 guage and labour charges for straightening, cutting etc of the M.S. rods or tor steel and tying grills and placing in proper position as per specification and direction of the Engineer-in-charge. work with minimum compressivee strength in work test of 150kg/cm2 in 15cm cum cubes at 28 days cost and conveyance of M.S. Rod or steel and binding wires of 18 to 20 guage and labour charges for straightening, cutting etc of the M.S. rods or tor steel and tying grills and placing in proper position as per specification and direction of the Engineer-in-charge. Column Base & Footing (Dispensary Building) |
| 26 | Column and Beam -D type Qtr ( Ground Floor) |
| 27 | Column Base and Footing -D type Qtr ( Ground Floor) |
| 28 | Roof Slab-D type Qtr ( Ground Floor) |
| 29 | Column Base and Footing -E type Qtr ( Ground Floor) |
| 30 | Column Base and Footing -Compound Wall |
| 31 | Plinth Band-Dispensary Building |
| 32 | Plinth Band--D type Qtr ( Ground Floor) |
| 33 | Plinth Band--E type Qtr ( Ground Floor) |
| 34 | Plinth Band--Compound Wall |
| 35 | Column & Beam -Dispensary Building |
| 36 | Column and Beam -E type Qtr ( Ground Floor) |
| 37 | Column -Compound Wall |
| 38 | Lintel Beam-Dispensary Building |
| 39 | Lintel Beam-D type Qtr ( Ground Floor) |
| 40 | Lintel Beam-E type Qtr ( Ground Floor) |
| 41 | Chajja-Dispensary Building |
| 42 | Chajja-D type Qtr ( Ground Floor) |
| 43 | Chajja-E type Qtr ( Ground Floor) |
| 44 | Roof Slab-Dispensary Building |
| 45 | Roof Slab-E type Qtr ( Ground Floor) |
| 46 | Straightening bent up or coiled rods cutting bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor steel and binding wires and tying the grills hoisting lowering and placing in proper position as required for RCC works with cost, conveyance and taxes of M.S. Rods or Tor steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. (Weight of binding wires will not be considered for payment and payment will be made on weight of M.S. Rods or Tor steel only).(Dispensary Building) |
| 47 | D type Qtr ( Ground Floor) |
| 48 | E type Qtr ( Ground Floor) |
| 49 | Compound Wall |
| 50 | Providing 20 mm thick grading plaster in C.M.(1:4) over roof slab after chipping and chiselling the same and cleaning the surface by wire brushing laid to proper slope finished smooth including watering and curing with cost, conveyance of materials labour, Tand P required for the work including royalty etc.complete as per direction of the Engineer-in-charge.(Dispensary Building) ( First Floor) |
| 51 | D type Qtr ( Ground Floor) |
| 52 | E type Qtr ( Ground Floor) |
| 53 | Labour for fitting and fixing of M.S. windows and door shutters and collapsible gate with top and bottom rails in proper position including making holes in walls in proper position including making holes in walls RCC structure and wood work etc. and making good to the damages to walls or RCC structures including mending, or cutting to sizes or grooves in walls and fixing with RCC (1:2:4) with hard black broken granite stone chips of 12mm to 20mm (1/2 to 3/4) (20mm not to exceed 25percent ) with cost, conveyane, royalty and taxes of all materials, labour, T and P articles requried for the work etc complete as per specification and direction of the Engineer-in-Charge( Dispensary Building) |
| 54 | D type Qtr ( Ground Floor) |
| 55 | E type Qtr ( Ground Floor) |
| 56 | Compound Wall |
| 57 | Supplying, fitting & fixing of Flush Door as per specification including cost of all materials and labour charges.( Dispensary Building) |
| 58 | D type Qtr ( Ground Floor) |
| 59 | E type Qtr ( Ground Floor) |
| 60 | Supplying, fitting and fixing of WPC type door for toilet with laminate as per specification including cost of all materials and labour charges.( Dispensary Building) |
| 61 | D type Qtr ( Ground Floor) |
| 62 | E type Qtr ( Ground Floor) |
| 63 | Supplying fitting and fixing of two track UPVC sliding window of approved make with 6 mm thick glass of approved quality complete with frame , shutters and all fittings and fixtures T&P etc. as per specification and as per direction of the Engineer-in-Charge.( Dispensary Building) |
| 64 | D type Qtr ( Ground Floor) |
| 65 | E type Qtr ( Ground Floor) |
| 66 | Providing 20mm thick cement plaster (1:6) finished smooth to inside surface of brick walls after racking out the joints including watering and curing with cost and conveyance of all materials and labour with T and P required for the work with all taxes and royalties etc. complete in all respect as per specification and direction of the Engineer-in-Charge. (Dispensary Building) |
| 67 | D type Qtr ( Ground Floor) |
| 68 | E type Qtr ( Ground Floor) |
| 69 | Providing 12 mm thick C.P. in C.M.(1:4) to R.C.C surface finished smooth including closed deep chiping with cost, conveyance of materials labour, T and P required for the work including royalty etc.complete as per direction of the Engineer-in-charge.( Dispensary Building) |
| 70 | D type Qtr ( Ground Floor) |
| 71 | E type Qtr ( Ground Floor) |
| 72 | Providing 12mm thick cement plaster (1:6) finished smooth to outside brick walls after raking out the joint including watering and curring with cost and conveyancec of all materials and labour with T and P required for the work with all taxes and royalities etc. complete in all respect as per specification and direction of the Engineer-in-Charge ( Dispensary Building) |
| 73 | D type Qtr ( Ground Floor) |
| 74 | E type Qtr ( Ground Floor) |
| 75 | Compound Wall |
| 76 | Supplying, fitting & fixing vitrified tile in floors of size 600mm x 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of materials, labour T and P etc required for the work all complete as per direction of Engineer-in-charge( Dispensary Building) |
| 77 | D type Qtr ( Ground Floor) |
| 78 | E type Qtr ( Ground Floor) |
| 79 | Fixing tiles in Dadoos, skirting and risers of steps on 12 mm thick cement plaster(1:3) joined with neat cement slurry mixed with pigment to match the shade of the tile etc. complete as per direction of Engineer-in-charge.( Dispensary Building) |
| 80 | D type Qtr ( Ground Floor) |
| 81 | E type Qtr ( Ground Floor) |
| 82 | Finishing surface of walls with one coat of cement based wall putty (water based ) ,cement primer and plastic emulsion paint of approved make and finished smooth & even surface to receive painting including cost of scaffolding staging charges with cost of all materials , taxes , labour with T and P etc. complete as per Engineer-in-Charge.( Dispensary Building) |
| 83 | D type Qtr ( Ground Floor) |
| 84 | E type Qtr ( Ground Floor) |
| 85 | Priming one coat with any approved primer over plastered surface as per direction of the Engineer-in-charge. (Dispensary Building) |
| 86 | D type Qtr ( Ground Floor) |
| 87 | E type Qtr ( Ground Floor) |
| 88 | Compound Wall |
| 89 | Distempering two coats with approved shade incl. cost of all material, labour and T and P etc. complete ( Dispensary Building) |
| 90 | D type Qtr ( Ground Floor) |
| 91 | E type Qtr ( Ground Floor) |
| 92 | Finishing walls with weather coat of approved shade on new work two coats to give an even shade including cost of paint. ( Dispensary Building) |
| 93 | D type Qtr ( Ground Floor) |
| 94 | E type Qtr ( Ground Floor) |
| 95 | Compound Wall |
| 96 | Painting two coats of enamel paint to new wood work and iron work including cost of paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T and P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge..( Dispensary Building) |
| 97 | D type Qtr ( Ground Floor) |
| 98 | E type Qtr ( Ground Floor) |
| 99 | Compound Wall Please Enable Macros to View BoQ information |