| 1 | Common items for JOB 'A', 'B', 'C', 'D', 'E', 'F', 'G' (B/R portion) |
| 2 | Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) including removal of debris ouside MoD land complete all as specified and directed. |
| 3 | M&L for double charge vitrified ceramic tiles light shade, 8 to 9 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in floorings with border of dark shed over and including 15mm thick screed bed in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match in white or coloured cement to match etc complete all as specified and directed. |
| 4 | S&F powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips, locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm incl (two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) including all necessary all fittings as per manufacturer's instructions complete all as specified and directed. |
| 5 | S&F power coated aluminium door shutter with frame fixed including roller machine with rubber gasket, stopper, cleats, handles etc including aluminium door styles of size 80 mm x 38 mm x 2.00 mm and aluminium door section of top, bottom and lock rail shutter frame of 80 mm x 38mm x 2.00 mm and 4.8 mm thick glass & 9mm thick particles board as per requirement including taking down old door with necessary all fittings complete all as specified and directed. |
| 6 | S&F Aluminium (extruded section body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed etc, complete all as spcified and directed. |
| 7 | S&F 0.9 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instruction complete all as specified and as directed. |
| 8 | Common items for JOB 'A', 'B', 'C', 'D', 'E', 'F', 'G' (E/M portion) |
| 9 | M&L for point wiring for one light/ bell/ fan controlled by one number one way switch for 5Amps SSC complete with 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two runs single core for phase and neutral drawn through in and including PVC concealed conduit of suitable size (minimum 20mm dia medium grade, ISI Marked) with one run of 1100V grade FRLSH PVC insulated multistranded copper conductor cable 1.5 Sq mm single core green colour for earth continuity conductor and connecting to common earth dolly incl provn of modular type galvanized MS sheet pressed sunken box not less than 1.00 mm thick concealed on wall including fixing of modular cover plate of suitable modules with fixing screws, for fixing of modular type switches/socket/fan regulator, etc. including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing surrounding surface complete all as specified and directed.Note : Proper colour code of wiring to be maintained. |
| 10 | All as per BOQ Serial Item No.7.1 above but for 5 A socket point on independent board complete all as specified and directed. |
| 11 | All as per BOQ Serial Item No.7.1 above but for 15 A socket point in independent board with 2.5 sqmm 1100V grade FRLSH PVC insulated copper conductor complete all as specified and directed. |
| 12 | S&F modular type switch, one way, 6 Amps, 1 module complete all as specified and directed. |
| 13 | S&F modular type socket, 5 pin, 6 Amps, 2 module complete all as specified and directed. |
| 14 | S&F Modular type socket, 5 pin, 16 Amps, 2 module complete all as specified and directed. |
| 15 | S&F Modular type switch, one way 16 Amps, 1 module complete all as specified and directed. |
| 16 | S&F Modular type fan regulator, step type (2 module) 120 Watt complete all as specified and directed. |
| 17 | S&F polycorbonate/PVC ceiling rose of size 65x50 mm single phase with 3 terminal complete all as specified and directed. |
| 18 | S&F in repairs MCB 06 Amps to 32 Amps, single pole, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 19 | S&F wall mounted fan 300-450 mm sweep, voltage range 220V to 230 volts, 50 Hz, single phase complete with speed regulator and oscilator with pulling threads complete all as specified and directed. |
| 20 | S&F exhaust fan made of sturdy engineering plastic with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 250 mm complete all as specified and directed. |
| 21 | M&L for circuit/sub-main wiring (surface type) with two runs of 1100 Volt grade FRLSH PVC insulated & unsheathed single core multi stranded copper conductor cable 4.0 Sqmm alongwith one run of 1100 Volt grade FRLSH PVC insulated & unsheathed single core multi stranded copper conductor cable 4.0 Sqmm for earth continuity conductor connected to common earth dolly, drawn through & including PVC casing caping complete all as specified and directed. Note : Three runs of 4.0 Sqmm cable shall measured as one length. |
| 22 | S&F MCB 06 Amps to 32 Amps, SPN, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and directed. |
| 23 | Supply, installatioin, commissioning and testing of split type air condtioner of 2.0 TR, digital inverter type, with cordless remote control unit with LCD/LED display, minimum 3 star rating and EER of 3.2 and above. Indoor unit Hi wall mounted type suitable for 230 volts, 50 Hz, single phase AC supply and capable of performing the function as cooling , air circulating and filtering. Outdoor unit of the air conditioner shall be fitted with discharge cool type rotary/ scroll compressor operating on non-CFC refrigerants (like R410 A or equivalent) with over load protection and mounted on resistant mountings for quite operation. The filters packs provided shall be washable. Remote cordless control shall be provided with ON/OFF timer, fan speed selector (min 3 speed), mode selector (cooling/fan) and setting -up of temperature. Display of temperature and mode shall be provided on indoor unit and on handset. Overall power factor of the unit shall not be less than 0.85 at operating conditions. Indoor and Outdoor unit should have 100% copper coil complete all as specified and directed. Note :- The installation shall include mounting/ fitting indoor and outdoor unit on wall with suitable bracket etc. at respective locations. Laying refregerent piping, extension of drain pipe upto 6 mtr length and connecting both units after drilling holes, putting PVC sleeve, sealing and finshing the same duly matched with adjoining surface. Refrigerant pipe shall be insulated with expanded polythylene foam not less than 5mm thick. Leak testing of the entire system after installation to be carried out. Rate quoted will include Charging refrigerant gas in the unit, suitable electric connection between indoor and outdoor unit (upto 6 mtr) and upto switch (upto 3 mtr) |
| 24 | S&F AC voltage stabilizer 170-270 V for upto 2 Ton AC with output voltage capacity 5KVA complete all as specified and directed. |
| 25 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 26 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed. |
| 27 | Supply and laying of DWC Pipe of 40mm dia complete all as specified and directed. |
| 28 | Supply and Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade for 50 sqmm 3.5 core of cables complete all as specified and directed. |
| 29 | S&F in repairs MCCB, 3 pole, 415 V, upto 100 Amp, 16 kA complete all as specified and directed. Please Enable Macros to View BoQ information |
| 30 | S&F in repairs MCCB, 3 pole, 415 V, upto 100 Amp, 16 kA complete all as specified and directed. Please Enable Macros to View BoQ information |