| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out,completeall as specified and as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out,complete all as specified and as directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out all as specified and as directed. |
| 4 | M & L for PCC 1:3:6, type C-2, using (40mm graded stone aggregate) as foundation, filling and mass concrete. |
| 5 | M&L Deformed TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 6 | M&L Deformed TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 7 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 8 | M&L for Formwork to Square, rectangular or polyg-sides of pillars, posts, struts, piers, columns and stanchions |
| 9 | M&L for RCC design mix M-25 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete,complete all as specified and directed. |
| 10 | M&L for RCC design mix M-25 in Columns, pillars, piers, posts and struts etc,complete all as specified and directed. |
| 11 | M&L for RCC design mix M-25 in Beams, cantilevers, bressummers,lintels over 1.5m span etc,complete all as specified and directed. |
| 12 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in, using cement mortar 1:6 ,complete all as specified and directed. |
| 13 | Supply only Integral waterproofing compound |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 15 | Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area |
| 16 | M&L for RCC design mix M-25 (20mm graded aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like,complete all as specified and directed. |
| 17 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),complete all as specified and directed. |
| 18 | M&L for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified,complete all as specified and directed. |
| 19 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing ,complete all as specified and directed. |
| 20 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing ,complete all as specified and directed. |
| 21 | M&L for Cement concrete type type C-2, 1:3:6 (40mm graded aggregate)drawing ,complete all as specified and directed. |
| 22 | M&L for 100 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) ,complete all as specified and directed. |
| 23 | M&L for Screed bed or bedding layer of mortar 20 mm thick, ratio1:6 for laying floor finishes ,complete all as specified and directed. |
| 24 | M&L for 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) ,complete all as specified and directed. |
| 25 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete ,complete all as specified and directed. |
| 26 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement,complete all as specified and as directed. |
| 27 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Priming with alkali resistant priming paint including the prepration of wall,complete all as specified and as directed. |
| 28 | M&L for two coat of white wash on internal wall including the prepration of wall,complete all as specified and as directed. |
| 29 | M&L for two coat of OBD over the one coat of primer on internal wall.including the prepration of wall,complete all as specified and as directed. |
| 30 | M&L for ATT treatment the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and as directed. |
| 31 | M&L for ATT treatment the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified and as directed. |
| 32 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed |
| 33 | M & L for cleaning the newly plastered surfaces of concrete with wire brushes and applying water proofing treatment as under :- (i) Apply one coat of bituminous primer @ 0.10 kg/Sq.M (ii) Providing and laying by torch application method APP polymeric modified bituminous water proofing membrane with non woven polyester mat as reinforcement membrane 3mm thick with bituminous plain finish on upper side weighing not less than 3.5Kg/Sqm procured from any of the approved manufactures(iii) Apply one coat of bituminous approved aluminium paint @ 0.11Kg/Sqm |
| 34 | S&F for Anodised aluminium window and ventilator shutters with powder coating of any colour (Thickness or powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified,complete all as specified and as directed |
| 35 | Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including stove enamelled steel conduit complete with all fittings and accessories,fixed to recessed/walls/ceiling, including stove enamelled black steel junction box, with cover and outlets and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for,one 3 Pin 5 Amps socket outlet independent complete all as specified and directed. |
| 36 | Supply and Fix,switch flame proof rotary type with termination box in LM6,16A,single pole 250V,complete all as specified and directed. |
| 37 | Supply and Fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.,complete all as specified and directed. |
| 38 | Supply and Fix,flame proof Ceiling fan with rugulator 48 inch single phase complete all as specified and directed. |
| 39 | Supply and Fix, 100 mm dia.,cast aluminium body LM6, flame proof,weather proof junction box 4 way terminal with 4 number of 3/4 ET cable entry, protection type Ex-D,Zone 1 & Zone 2,IP-55,Gas Group IIB,Temp Class T6,complete all as specified and directed. |
| 40 | Supply and Fix, flame proof, weather proof enclosure for MCB Distribution Board Single Phase and Neutral,6 Way with incoming & outgoing terminals chamber, bus bar chamber comprising of 02(Two) Nos. copper bus bars of suitable rating,separate MCB chambers suitable for accommodating 05 (Five) Nos. one number incoming MCB 2P 32A and four number outgoing MCB single pole 6/10 Amp 'C' curve,enclosure made of cast aluminium alloy LM6, weather proof IP65, finished inside and outside with light grey epoxy powder coating, including cable glands, terminals, hardware and mounting arrangement all as per enclosure size 300x300x190mm) Make Balinga/Shyam/sudhir complete all as specified and directed. |
| 41 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including stove enamelled steel conduit complete with all fittings and accessories,fixed to recessed/walls/ceiling, including continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed. Please Enable Macros to View BoQ information |
| 42 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including stove enamelled steel conduit complete with all fittings and accessories,fixed to recessed/walls/ceiling, including continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed. Please Enable Macros to View BoQ information |