| 1 | S&F Anodised aluminium frame for doors, windows, ventilators and kitchen cupboards frame with one or more rebates including joining cleat for fixing etc. complete all as specified add for powder coating (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 2 | S&F Anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed add for powder coating (minimum thickness of powder coating 50 micron) |
| 3 | S&F in repairs alumunium patition panels/ composite panels/ACP sheets fiexed on aluminium frames or on sliding aluminium frame work with aluminium glazing clips/ beading as in cupboards, partitions etc and size and colour shall be finalised by GE complete all as specified and directed |
| 4 | S&F in repairs aluminium powerded coated (minum 50 micron) anodised partition wall with aluminium frame of size :- (a) Single Groove Section: 82.50 mmx 38mm x 1.20 mm thick (b) Double Groove section: 82.50mm x 38mm x 1.10 mm thick duly fitted with neosprene rubber beading,frosted glass panes 4.8 mm nominal thickness or 12mm thick prelaminated melamine faced both sides decorative, exterior grade type II particle board panels including securing with 'U' channels at top joining partatio complete all as specified and directed |
| 5 | S&F in repairs powder coated aluminium sliding windows frame with movable shutter (sliding on minimum two PVC roller of best quality) for each shutter on three tracks or two track as required with stainless steel mosquito proofing and glazing shutter and including glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips, frame made with aluminium section as appended below- (i) Window frame of minimum size : 92mm x38 mm X 1.5 mm thick for three tracks. (ii) 63mm x38 mm X 1.15 mm thick for two tracks. Note : The rate for glass & wire mesh shall not be paid separately. complete all as specified and directed |
| 6 | S&F Anodised aluminium window, ventilator shutters and kitchen cupboards, side hung type/ slidding type without sash bars, alumimium section weighing 0.55 kg/m including necessary joining cleats glazing clips, ruber packing, anodised aluminium snap beading screws anodised aluminium fittings such as ped stays 150mm long (1 No) hinges type B-21 100mm long (2 No) suitable handle (1 No) complete all as specified for add powder coating (minimum thickness of powder coating 50 micron) complete all as specified and directed |
| 7 | Repair of aluminium door/window/ ventilator/ partition wall etc of any size / any number of panels including taking down (if required) & refixing for easy closing/ opening/ tightening of hinges or changing the position of hinges, adjustment of floor door spring of hydraulic door closure, adjustment of tower bolts, sliding bolts etc changing of mortice lock complete all as specified and directed |
| 8 | Dismantling of roof terracing, cement mortar, brick padding, concrete (un-reinforced) alongwith existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all loose dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material outside of MOD land complete all as specified and directed. |
| 9 | M & L for providing PCC 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, haunching, coping, curved filllet and similar works of over RCC roof surface including rounded or chamferred on edges complete all as specified and directed. |
| 10 | M & L for rendering 15 mm thick cement plaster in cement mortar 1:3 including mixing of liquid water proofing compound @ 200 ml per 50 kg of cement over concrete roof surface finished even and smooth without using extra cement complete all as specified and directed. Note- water proofing compound shall not be paid separately. |
| 11 | M & L for providing polymer based waterproofing membrane (IWL Hyperplas Polyster manufactured by IWL, Super Thermolay manufactured by STP Limited, Torch Shield AP manufactured by Pidilite Industries) minimum weighing 3.50 Kg per sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 Grams per sqm) laid by forced torch application having minimum 10 cm end laps both ways, over and including polymeric primer @ 0.30 Litre per sqm and polymeric modified bitumen @ 1.20 Kg per square metre after cleaning of roof surface complete all as specified and directed. |
| 12 | M & L for applying three coats of fiber reinforced elastomeric liquid water proofing treatment on roof/terrace/podium surfaces and like incluing crack seal treatment as per manufacturer intructions, formulated with select elastomeric and resilient acrylic polymers and reinforcing polyester fiber, upon curing, forms a thick seamless, durable treatment. Apply self priming coat with 33% of water dilution in a verticle or horizontal surface. Treatment should be viscous liquid apprearence & colour white and applied in following procedure :-(a) Apply first coat of the material shoulde be in both direction of surface without dilution to achieve a forced system coverage of 0.93 sq metre per liter. Allow it to dry for 4-6 hours between coats. (b) Apply second coats without dilution to achieve the forced system coverage of 1.20 sqm per liter on perviously painting surface with high quality. Allow it to dry for 4-6 hours between second and third coats. (c) Apply Third coats without dilution to achieve the forced system coverage of 2.32 sqm per liter on perviously painting surface with high quality. Allow it to dry for 4-6 hours before exterior emulation plaint (d) Apply two coats external emulsion of the painting surface. Allow it to dry 4-6 hours between coats.(Colour to be approved by GE) Note :- Executive as per manufacture instruction. rate shall be Including scaffolding, trestles, ladders cradles and necessary safety measures complete all as directed by Engineer-in-chage. |
| 13 | M & L for applying two coats of Aluminium paint on APP membrane surface of any description not otherwise described over 10 cm width or girth as specified and directed. |
| 14 | S&F in repairs PVC boards 18/19 mm thick any colour/ prelaminated as in cabinets including shelves and shutters, fixed with screws and adhessive as per direction of Engr-in-Charge and, manufacturer's instructions including piano hinges, magnet catcher, handles etc. complete all as specified and directed |
| 15 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n. exc 1.5 sqm including removing from the premises complete all as spd and directed |
| 16 | Taking down chowkhat or frame with shutter (without taking off single shutter/ double shutter from the frame)exc 1.5 sqm and n exc 4.00 swm including removing from the premises complete all as spd and directed |
| 17 | Taking down shutter of any description exc 1 sqm and n/exc 2 sqm each including removing from the premises complete all as spd and directed |
| 18 | S&F 2nd class hard wood chowkhat or frames, plain solid, wrought, framed and rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified & directed by Engr-in-Charge |
| 19 | S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube all as specified or as directed. |
| 20 | S&F factory made solid panel PVC door shutter 30mm thick (style) one side prelam pvc in place of plain and another side decorative, consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width strucks inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either to side and as gap insert for top rail & bottom rail panelling to be fitted in MS frame welded/sealed to stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as specified of drawing. complete all as specified and directed |
| 21 | S&F for 105mmx60 mmx 1.25mm thick pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS bar/flat at bottom of the frameetc, including wooden texture finished paint on the frame surfacecomplete all as spd and directed. |
| 22 | S&F for 125mmx60mmx1.25 mm thick pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS bar/flat at bottom of the frame etc, complete including wooden texture finished paint on the frame surface all as specified and directed. |
| 23 | S & F 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints, complete including treating theback of chowkats with coal tar black paint. complete all as specified and directed |
| 24 | S& F for Flush shutters, 30 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed |
| 25 | S&F 2nd class hardwood glazed and Skelton shutters 35 mm thick open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, stiles and rails as specified in SSR Part I section 8 clause 8.20 (a) supplied and fitted to chowkhats complete all as specified and directed Please Enable Macros to View BoQ information |
| 26 | S&F 2nd class hardwood glazed and Skelton shutters 35 mm thick open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, stiles and rails as specified in SSR Part I section 8 clause 8.20 (a) supplied and fitted to chowkhats complete all as specified and directed Please Enable Macros to View BoQ information |