| 1 | Earth work in excavation by mechanical means (Hydraulic Excavat in foundation trenches or drains (not exceeding 1.5 m in width or 1 including dressing of sides and ramming of bottoms, lift upto 1.5 out the excavated soil and disposal of surplus excavated soil as dir of 50 m. All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20cm in de consolidating each deposited layer by ramming and watering, up to 50 m and lift upto 1.5 m. |
| 4 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 ( 1 cement : 6 coarse sand ) |
| 5 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shape and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 7 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability andworkability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability andworkability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above plinth level upto floor V level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. |
| 11 | Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 12 | Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. |
| 13 | Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 cm |
| 16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding |
| 17 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60m M.S. Sheet, joints mitred and welded and grinded finish profi required size with 15x3mm lugs 10cm long embedded in ce concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse graded stone aggregate 20mm nominal size) or with wooden plugs screws or rawl plugs and screws or with fixing clips or with b nuts as required including fixing of necessary butt hinges and and applying a priming coat of approved steel primers. |
| 18 | 12 mm cement plaster of mix in 1:6 (1 cement : 6 fine sand) |
| 19 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) |
| 20 | 6 mm cement plaster of mix. 1:3 (1 cement: 3 fine sand) |
| 21 | Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble |
| 22 | Providing and fixing Tiled False Ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @120 gsm/sqm. both side inclusive) consisting of main \\"T\\" runner with suitably spaced at joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross \\"T\\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge.GI Metal Celling Lay in plain Tegular edge Global white color tiles of size 595x595xmm, and 0.5 mm thick with 8 mm drop made of G.I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimun), factory painted after bending. |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3: cement :3 coarse sand : 6graded stone aggregate 20mm no size) over 75mm bed by dry brick ballast 40mm nominal siz rammed and consolidated and grouted with fine sand includin finishing the top smooth. |
| 24 | Brick edging 7cm wide 11.4cm. deep to plinth protection wit bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) |
| 25 | Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 26 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic) 300x16 mm |
| 27 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not) 125 mm |
| 28 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating ) 250x10 mm |
| 29 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper |
| 30 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 31 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 33 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 34 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 35 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 36 | Renewing glass panes, with putty and nails wherever necessary. Float glass panes of thickness 4 mm |
| 37 | Windows using galvanised M.S. wire gauge with average width of a in both directions with wire of dia. 0.63 mm. With 12 mm mild steel U beading. |
| 38 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 39 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 41 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter |
| 42 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and loors wherever required :W.C. pan with ISI marked black solid plastic seat and lid |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitti i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 15 mm nominal outer dia .Pipes. |
| 45 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cemen trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External work). 15 mm nominal outer dia .Pipes. |
| 47 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 48 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 49 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore |
| 50 | Providing &fixing 8 mm dia C.P/S.S Jet with flexible tube up to 1 meter long with S.s triangular plate to Europion type W.C of quality and make as approved by Engineer in Charge. |
| 51 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 52 | Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 15 mm nominal bore |
| 53 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item Bend 87.5°(110 mm bend ) |
| 54 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item Bend 87.5°(75 mm bend ) |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item Coupler 110 mm |
| 56 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given Shoe (Plain) 110 mm Shoe |
| 57 | Providing and fixing unplasticised -PVC pipe clips of approved each design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete. 110 mm. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given |
| 58 | Providing and fixing to the inlet mouth of rain water pipe each cast iron grating 15 cm diameter and weighing not less than 440 grams. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given |
| 59 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983 Kitchen Sink without drain board 470x420 bowl with 178 mm bowl depth |
| 60 | Providing and fixing PTMT soap Dish Holder having length of 138m 102mm, height of 75mm with concealed fitting arrangements weig than 106 gms. |
| 61 | Providing and fixing 600x450 mm bevelled edge mirror of superior quality) complete with 6 mm thick hard board ground fixed to woo C.P. brass screws and washers complete. |
| 62 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms |
| 63 | Providing and fixing uplasticised PVC connection pipe with brass unions. 45 cm length. 15 mm nominal bore. |
| 64 | Providing and fixing square-mouth S.W. gully trap grade ‘A” complete with C.I. 100x100 mm size p type with FPS pipe class 75 mm |
| 65 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 66 | Steel work welded in built up section/framed work including cuttin in position and applying a priming coat of approved steel primer us required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Please Enable Macros to View BoQ information |