| 1 | Dismantling floors, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises. |
| 2 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed by Engineer-in- Charge. |
| 3 | M&L for glazed ceramic coloured tiles 7 to 8 mm thick on vertical surfaces 350 x 250mm / 450 x 300mm, etc set and jointed in neat cement slurry and pointed in white or coloured cement over 10mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer In-Charge. |
| 4 | M & L for White/ Colour Non skid Ceramic tiles 8 mm thick (square/ rectangular) polished, area of each tiles n exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with rectified edges ( joint free) etc set and jointed in neat cement slury over cement screed 15 mm thick 1:6. |
| 5 | M & L for White/ Colour Non skid Ceramic tiles 8 mm thick (square/ rectangular) polished, area of each tiles n exceeding 0.38 sqm , in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with rectified edges (Joint free) as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and incl 10 cm thick backing with cm 1:4. |
| 6 | Taking up or down steel tubing and connections, and removing to store for taking in account of credit for 20 mm bore |
| 7 | Taking up or down steel tubing and connections, and removing to store for taking in account of credit for 25/32 mm bore |
| 8 | Supplying and laying 20mm OD of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 9 | Supplying and laying 25mm OD of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 10 | Disconnecting existing tanks, setting aside (or lowering if required) in repairs and Supply, Hoisting and fixing 500 Litre Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I . |
| 11 | S &F 25mm Tank Adaptor |
| 12 | S &F 25mm UNION |
| 13 | S &F 25mm Gate VALVE |
| 14 | S & F in repairs 40/50mm Float valve high pressure, with self closing type with ball polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to tank |
| 15 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete/ PVC) set incement mortar of pipe below 150 mm dia complete. |
| 16 | S&F PVC (SWR)110mm bore pipes single sockted in any length with rubber ring joints laid fixed to walls/floors |
| 17 | S&F PVC (SWR) 75 mm bore pipes single sockted in any length with rubber ring joints laid fixed to walls /floors |
| 18 | S&F PVC (SWR) bends any radius 110 mm bore |
| 19 | S&F PVC (SWR) bends any radius 75 mm bore |
| 20 | S&F PVC (SWR) ,single access door (single Y) equal or unequal 110 mm bore including neessary fittings, clamps etc. |
| 21 | S&F PVC (SWR) ,single access door (single Y) equal or unequal 75 mm bore including neessary fittings, clamps etc. |
| 22 | S&F PVC (SWR) 75 mm bore vent cowl |
| 23 | S&F PVC (SWR) 110 mm bore vent cowl |
| 24 | Supply and fix in repairs Vitreous china premium wash down water closet floor /wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. complete in all respect all as specified, including accessoreis i.e seat cover, Health facet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified Including fixing ito 110mm SWR pipe with necessary traps all as specified and directed. |
| 25 | Supply and fix in repairs plastic water closet seat cover, white, closed pattern with flat bottom and cover all as specified and as directed. |
| 26 | S&F in repairs fancy type long body Bib taps, chromium plated with cruch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore. |
| 27 | Supply and fix in repairs 15mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and as directed. |
| 28 | S&F in repairs chromium plated angle valves/ self closing taps, cast copper alloy, screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipes or for unions and fixed. 15 mm size. |
| 29 | Supply and fix in repairs low level PVC flushing cistern white complete with syphonic action type 10 litre capacity including float valve handle, bracket, PVC flush down pipe 32mm dia as required with bend, PVC connection 450mm long with PTMT nut and washers etc complete all as specified and as directed. |
| 30 | S&F in repairs 600mm x 450mm fancy type frameless looking mirror of selected quality glass. |
| 31 | S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm |
| 32 | S & F in repairs fancy type Towel Rail 600mm long of SS fixed with and including necessary screws and wooden/plastic cleats. |
| 33 | S & F in repairs fancy type glass Shelf with bracket fixed with and including Chromium plated brass screws and wooden/plastic cleats |
| 34 | S & F in repairs Fancy type Shower arm 15 mm size, 195mm long with bend of 45degree with flange made up of SS all as specified and directed. |
| 35 | S & F in repairs 125mm & below Grating round/ square of any shape of PTMT. |
| 36 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 37 | S & F in repairs Vitreous China wash basin, wliile, flat back, size 580x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets Wash basins, any size, including cutting for and pinning in ends of brackets or erecting stand of including fixing of supply and waste pipe |
| 38 | S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm |
| 39 | Taking down cement plaster on brick or stone walls, ceilings, roof slab etc including racking out Joints, hacking for key, scrubbing down with water, etc |
| 40 | M&L for Rendering 15mm thick in two layer of 10mm thick over 5mm thick each on fair faces of concrete surfaces in CM 1:4 mixing with integral water proofing compound (WPC) @ of 3% of cement and finished even and smooth (without using extra cement) over cleaned, brushed by wire brush and washed by water etc complete all as specified and as directed. Note :- WPC will be measured and paid separately as supply only. |
| 41 | Supply only water proofing compound |
| 42 | Material & Labour for applying Two coats of acrylic emulsion paint of Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied on new plastered surfaces of walls complete as mentioned in SSR all as specified and as directed . |
| 43 | M & L for 10mm thick cement plastering with cement mortar 1:4 brick or concrete surfaces of ceiling finished fair and even complete all as specified and directed. |
| 44 | Material and labour Two coats of Oil bound distemper over a coat of alkali resistant primer on walls, pillasters, cornices, etc., on newly plastered walls including preparation of surfaces with 1mm wall care putty all as specified and as directed. |
| 45 | Material and labour one coats of Oil bound distemper over a coat of alkali resistant primer on walls, pillasters, cornices, etc., on old plastered walls including preparation of surfaces all as specified and as directed. |
| 46 | Dismantling wall and ceiling boards (Fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets, frame work all as directed. |
| 47 | Material and labour for providing aluminium powder coated snap grid frame work supported by hanger 6mm dia GI (up to length as per site requirement) for false ceiling, adjusting level fixed to roof slabs/ walls/wooden members by means of ceiling cleats made out of GI flat 40x3 mm size 60 cm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified for false ceiling fixed with screws as per manufactures instructions |
| 48 | M & L Perforated particle board/ tiles in false ceiling for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber framework or with staples on snap grid all as specified by Engr in charge. |
| 49 | Removing soil/ building materials/ debris Malba etc. to a distance of 15km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination away from the defence land |
| 50 | Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of AFAC, Coimbatore area under AGE (I) (AF) Coimbatore of internal electrification nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES from DB's box / Electric Meter having switch, fuses, MCB distribution board in sheet metal enclosure, point wiring, fixture for light/ Fan/bell/light or power sockets complete replace with new one or repairs to the extent by removing connections from the system, removing faults in wires, batten, conduit, sunk boxes, junction boxes, main switches, MCBs/DBs utility light fittings, FTL light fitting any wattage lamp, holders, ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as insulation wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users. Note (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complain register and in complaint slip (ii) Complaint slip and complain register will be provided by the contractor without any extra charge. (iii) Complaint regiter will be produced on daily basis to JE and Engr-in-charge 24 Hrs of time. (iv) Contractor shall employee having minimum four year experiance electrical work in the said field. (vi) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’. (vii) Contacrtor failing to atttend the complient with in time impose necessary penalty of Rs 1000 per complient per day till the time of rectification. (viii) Contrator deploy the electrician with helper daily excluding sunday and holidays without fail and necessary attendence register produced to Engr -in Charge whenever demanded all as directed |
| 51 | Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified. |
| 52 | Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed. |
| 53 | Disconnecting electric connection and taking down main switch/SPN DB/TPN DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface. |
| 54 | M&L for Point wiring one light/bell point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls/surface and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases and making good in wall / floor will be Measured and paid seperately. |
| 55 | All as per item No 54 herein before but one ceiling/exhaust fan point controlled by one, one way switch. |
| 56 | All as per item No 54 herein before but one 05 Amps socket outlet point on same board. |
| 57 | All as per item No 54 herein before but one switch socket outlet point 5 Amps on independent board. |
| 58 | All as per item No. 54 here-in-before but with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board. |
| 59 | All as per item no 54 above but copper conductor FRLS 4 Sq mm |
| 60 | All as per item No 54 above one light/fan/bell point in PVC casing caping suitable size including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM) |
| 61 | All as per item No 54 above one 5 amps socket point on same board in PVC casing caping suitable size including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM) |
| 62 | All as per item No 54 above one 5 amps socket point on independent board in PVC casing caping suitable size including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM) |
| 63 | All as per item No 54 above one 15 amps socket point on independent board with 2.5 sq mm FRLS copper conductor in PVC conduit suitable dia including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM) |
| 64 | S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed. |
| 65 | S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed. |
| 66 | S&F Modular Modular Bell Push 6A 1 Module complete all as specified and as directed. |
| 67 | S&F Socket, modular 6A - 2/3 pin combined 2 module complete all as specified and as directed. |
| 68 | S&F socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and as directed. |
| 69 | S&F Modular fan regulator step type 120 W, 2 module complete all as specified and as directed. |
| 70 | S&F normal steppad type fan regulator flush socket type complete all as specified and as directed. |
| 71 | S&F Switch piano flush type 6A single pole, one way all as specified and as directed. |
| 72 | S&F switch socket combination 2 in 1 6 amps flush type complete all as specified and as directed. |
| 73 | S&F switch socket combination 2 in 1 6/16 amps flush type complete all as specified and as directed. |
| 74 | Supply and fix T8 20 watts retrofit LED tube PC cool day light 240 volts high efficiency approx 110 luman per watt, power supply in single side connection 2 pin terminals including taking down unserviceable lights all as directerd Cat No LTP820N of luker or equivalaent Make - Bajaj, Philips, Wipro, Crompton, Halonix, Luker |
| 75 | Supply and fixing LED battern fitting 1 x 18/ 20W, powder coated white finish 220V,AC box type with driver, holder including LED lamp connecting up with three core white flexible copper conductor cable of suitable size from ceiling rose including taking down unserviceable lights all as directerd complete . Model T5 LT 20 Make - Bajaj, Philips, Wipro, Crompton, Halonix, Luker |
| 76 | Supply and fixing LED battern light fitting with high out put diffuser 5 watts 220 V AC with driver holder and LED lamp including connecting up with white three core flexiblecopper conductor cable of suitable size including taking down unserviceable lights all as directerd complete model T5 LT505P. Make - Bajaj, Philips, Wipro, Crompton, Halonix, Luker |
| 77 | Supply and fixing round / squre shape 6/7 watt 220 Volt AC recessed type with hight efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 78 | Supply and fixing round / squre shape 9/12 watt 220 Volt AC recessed type with hight efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 79 | Supply and fixing round / squre shape 15/20/24 watt 220 Volt AC recessed/surface type with hight efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with three core white flexible copper conductor cable of suitable size complete. (Note : All recess mounted lights celing cutout size as per existing size at site) |
| 80 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 Watt, 220 V AC recessed/surface type with hight efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core white flexible copper conductor of suitable size complete. |
| 81 | S & F Call Bell Ding Dong AC 230 V single pole complete connecting up with flexible copperconductor cable of suitable size. |
| 82 | Supply and fix MCB DB, SPN, 8 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete. Make: L&T/Legrand/ Havells |
| 83 | All as per item No.81 above but DB SPN 12 ways (Note The existing serviceable MCB's refixing as per existing circuit/position all as directed) |
| 84 | All as per item No.81 above but DB TPN 4 ways (Note The existing serviceable MCB's refixing as per existing circuit/position all as directed) |
| 85 | Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, \\"B\\" Curve complete. Make: L&T/Legrand/ Havells |
| 86 | Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells |
| 87 | Supply and fixing TP 25 to 63 Amp rating 440 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells |
| 88 | Supply and fixing TPN/FP 16 to 32 Amp rating 440 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells |
| 89 | Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals. |
| 90 | M&L for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length. |
| 91 | All as per Item No 90 above but 4.0 sq mm. |
| 92 | All as per Item No 90 above but 4 runs of 6 sq mm |
| 93 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; andcutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth Please Enable Macros to View BoQ information |