| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 3 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 4 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats |
| 5 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of size Size of Tile 600 x 1200 mm |
| 6 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 7 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 1000x1000 mm |
| 8 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 9 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular toG.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 11 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 12 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 14 | 15 mm cement plaster on the rough side of single or half brick wall of mix:1:6 ( 1 cement : 6 fine sand) |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) |
| 17 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge. |
| 18 | Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self-adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. |
| 19 | Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete |
| 20 | Providing and fixing SS H handle having min 30cm length in toughed glass door including all necessary screws etc. complete |
| 21 | Vinyl Transparent Vision Glass Stickers: Supply and pasting of Vinyl Transparent Vision Glass Stickers in approved size and design in glass partition and door as per the instruction of Engineer in Charge. |
| 22 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 23 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 25 | Providing and fixing 10 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge. Pre- laminated particle board with decorative lamination on both sides |
| 26 | Backlit Acrilic Board with projected letters: Supply, installation, testing and commissioning of weatherproof backlit acrilic board with projected letters made upof 20mm thick acrilic board and having box depth of min 100mm in approved size and design with reqired LED strips for high glow light. The board shall be fabricated and fixed over suitable welded and painted 25X25X3mm MS angle frame in suitable location and in proper line and level with all necessary fastners, supports etc.Electrical works likes electrical wirings, connections, fittings, externaly fixed weather proof 2/3 pin plug points and sockets including boxes etc. to be complete properly. All fabrication and fixing should be done as per approved design and instructions of Engineer in Charge. (Note: Only front elevation will be measured.) |
| 27 | Providing and fixing partition up to ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange of 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of 12.5 mm thick single layer tapered edge plain gypsum plaster boards to both sides of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacturer’s specification and direction of Engineer-in-Charge all complete. 75 mm overall thickness partition with 12.5 mm thick single skin tapered edge plain gypsum plaster board conforming to IS: 2095 (Part 1): 2011 (Board with BIS certification marks). |
| 28 | Furniture |
| 29 | Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. |
| 30 | L-Type workstation of overall size (1350 * 600)mm + (1000 * 450)mm × 750 mm (L × D × H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) × 500 mm (D) × 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 31 | Supply of phlebotomy chair with optimum design made up of MS Power coated frame and up upholstery type seat,back rest and arm rests.Both side arm rest should be with height and position adjustable system and all as per the instruction of Engineer in charge. |
| 32 | Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications:Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make as per the instruction of Engineer in charge. |
| 33 | Supply and installation of visitors chair Medium Back, Mesh Back cushion seat with fixed supports made of 304 Stainless Steel/ powder coated MS of approved colour or shade as per the instruction of the engineer in charge |
| 34 | Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK |
| 35 | Cabinet/Wardrobe: Providing and errection of Cabinet/Wardrobe unit made with 18 mm thick prelaminated MDF board of one side decorative lamination and other side balancing lamination having total unit dimension of 900mm,L x 450mm,Dx 2400mm,H and all edges to be sealed with PVC edge beeding of 2.00 mm thick including all fittings such as autoclose hinges,chromium plated brass individual locks & handles ,tower bolts etc all required. All shelves to be fix with proper support and bracket holders at a spacing of 400 mm centre to centre and all as per the drawings and instruction of Engineer in charge. board make : Greenlam/ Merino / Century/ equivalent . Only front elevation will be measured. |
| 36 | Slotted Angle Racks : Supply and errection of Powder coated slotted angle metalic rack having min 8 shelfs made up of min 40 X 40 X 2 mm size rolled steel angle posts shall have 8-mm diameter holes provided at 50-mm centre to centre. Metal shelves shall be made from mild steel sheets not less than 1.0 mm in thickness and with sufficient stiffners. Shelves shall have lipped flanges width of flange being 30 mm and depth of lip 15 mm .Min size of rack 900mm Length X 300mm Depth X 2000mm Height. |
| 37 | Providing and erection of reception counter table of length 1200 mm and first level should be provided at a height of 750 mm and width 600 mm and the second level at a height of 1050mm from base with a width of 300. The table made of 18mm thick pre laminated Medium Density board of exterior grade (Grade I) IS: 14587:1998 with decorative laminated finish on both sides and 2 mm thick PVC beading on all edges, including electrical flip box, cable measurement tray, grommets with 3 nos universal power socket and ethernet port, three drawer pedestal unit with drawer channel, handles, hinges, lock all complete as per approved drawing and installation of Engineer in charge/Architect. |
| 38 | Supply of mounded Pantry Table with Heavy Duty stainless steel Legs with minimum dimension of 1200mmx 800mm |
| 39 | Supply of pantry chair as per the direction of Engineer in charge |
| 40 | Supply And Installation of Lab Workbench Material of Construction: GI as per IS277, Min thickness- 1mm or more (as required based on the design) Finish: Complete module and framework shall be powder coated and provided with suitable finish for maximum corrosion resistance (Colour as per the instruction from the HLL Engineer in charge) Minimum Dimension of Module: 750 mm (Width) x 900 mm (Height) Every one meter of the module shall be designed with min 2 drawers (with SS 304 telescopic channels and lockable drawing mechanism) and a single cabinet (With 2 shutters, SS304 hinges for easy and noiseless opening and closing mechanism), SS304 locks and dual keys arrangement, handles, screws etc Common Raceways (Powder coated GI with cover) for cabling electrical, network, voice connections with provision for fixing sockets, switch boxes etc. Raceway should be 3 run type.The workbench shall be portable and suitable for fixing granite table top as per specification ( granite slab shall be paid separately) The item should be in compliance with IS 4209 (2013), NABL, WHO etc. Measurement will be taken in length only. |
| 41 | Supply and Installation of Sink Module with Sink Each sink module should have a minimum dimension of 900 mm (L) x 900 mm (W)x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. |
| 42 | Work station table with toughened glass partition: - Table of size 1000x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board pull-out with necessary hardware like sliding channel cable manager, multipurpose locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 10mm thick toughened glass is to be provided on the table top at both sides and front at a height of 40 cm with an opening for cash transactions and smoothed edge. |
| 43 | Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. |
| 44 | Plumbing |
| 45 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 46 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 47 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 48 | Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 49 | Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall |
| 50 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 12 Kgf/ cm2 |
| 51 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 |
| 52 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 53 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 54 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow |
| 55 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 56 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 57 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 58 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 59 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 60 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap |
| 61 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling |
| 62 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 63 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 64 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 65 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 66 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 67 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 68 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 69 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 70 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 71 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 |
| 72 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 73 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia |
| 74 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 75 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 76 | Wiring |
| 77 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 78 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 79 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 80 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 81 | Fixtures |
| 82 | Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air |
| 83 | Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina |
| 84 | Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI & 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor & 0.95 and THD. Make-Philips, Crompton, Wipro or equivalent |
| 85 | Supply and Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI & 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification.Luminaire shall be designed to emit at least 1000 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor & 0.95 and THD. For light fittings to be installed in false ceiling, all required cuttings shall be made and damages shall be made good as per the direction of Engineer in charge. Make-Philips, Crompton, Wipro |
| 86 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 87 | Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI & 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 24 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor & 0.95 and THD. Make - Philips, Crompton, Wipro, Havells |
| 88 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 89 | DB and Switchgear |
| 90 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole |
| 91 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 92 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way(4+24), Double door |
| 93 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 94 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 95 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 63amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 96 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 97 | Supply, installation, testing and commissioning of a dust-proof and vermin-proof wall-mounted outdoor KSEB metering panel housed in a weatherproof synthetic (polycarbonate/FRP) meter box enclosure with lockable double doors, suitable for outdoor applications. The metering panel shall be UV-resistant, corrosion-free, and shall comply with the requirements of KSEB and the Electrical Inspectorate. The panel shall be equipped with one 125A, 16–25kA, 4-pole MCCB with thermal-magnetic release, one set of spreader terminals, and an LT type three-phase energy meter complete with a transparent viewing window for meter reading. The scope shall also include all necessary internal wiring, terminal blocks, gland plates, earthing arrangements, mounting accessories, and associated hardware required for complete installation. The enclosure shall have a minimum degree of protection of IP54 and the entire system shall be installed, tested, and commissioned in accordance with the latest EB, CEA, and Electrical Inspectorate regulations, complete. |
| 98 | Network System |
| 99 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 100 | Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. |
| 101 | Supply, installation, testing, and commissioning of 24-Port, 1U, Cat6A fully loaded shielded patch panel, suitable for high-speed structured cabling systems in data and networks. Make - Molex / Legrand / D-Link/ equivalent |
| 102 | Supply, Installation, Testing and Commissioning of 24-Port Network Switch having 48 Nos 10/100BaseT Port, with 2-Port 10/100/1000Mbps Copper, 2 Nos Combo Copper/SFP port complete including accessories. Make: D-LInk DGS-1052/Netgear GS348/Juniper EX4200 |
| 103 | Supply, laying, testing, and commissioning of CAT 6A U/UTP cable suitable for 10G Ethernet applications, including termination at both ends with suitable connectors as required. |
| 104 | CCTV System |
| 105 | Supply, Conveyance and Installing of 4/5MP IP Dome/Bullet Camera having 1/3" Progressive Scan True Day and Night Colour IR Camera having effective pixel of 4/5 MP, Video frame rate of 4/5MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 30-50 M IR Range, 24 IR LED, AWB, AGC, BLC, 2DNoise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell/Hikvision or equivalent |
| 106 | Supply, Installation and Integration of 8 channel embedded Linux PoE, NVR (Network Video Recorder), having dual core embedded processor, must connect 8 channel IP cameras , should support min 2 SATA HDD each of 6TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: Bosch/CP Plus/Honeywell or equivalent |
| 107 | Supply and Installation of Network Switch. 8 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 8 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az). Make: Cisco/CP Plus/ Netgear or equivalent |
| 108 | Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete |
| 109 | Supply of 2TB internal hard disk for use in Network Video Recorder (NVR) systems for CCTV/video surveillance. The hard disk shall be of surveillance-grade, specifically designed for 24×7 continuous operation and capable of handling multi-camera recording without data loss. The drive shall be of 3.5 SATA form factor with SATA III (6Gb/s) interface and optimized firmware for sequential write operations, vibration tolerance, low power consumption, and error recovery suitable for NVR workloads. The hard disk shall have a workload rating appropriate for continuous surveillance applications and be compatible with the specified NVR model. The supply shall include all necessary mounting accessories, cables, and connectors required for proper installation. |
| 110 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 111 | Supply, laying, testing, and commissioning of CAT 6A U/UTP cable suitable for 10G Ethernet applications, including termination at both ends with suitable connectors as required. |
| 112 | Supply and Installation of LED Color Monitor of minimum 21 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. |
| 113 | Supply installation, testing and commissioning of following Single phase to single phase UPS with battery backup, indoor (IP20) with surge protection system in stand alone configuration, true online double conversion DSP based UPS system, with min 15 min backup battery with, input pf>0.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and. The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard.10kVA Double conversion online UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 60 Minutes Backup and Battery |
| 114 | Fridge and visicooler |
| 115 | Visi Cooler/Pharmacy refrigerator: Supply, refection and commissioning of lab/pharmacy refrigerator as per following specification: Upright Show case Coolers/refrigerators with Single Glass Door and Lock having 350-450 Liter capacity, Temperature range capability 1-10 degree Celsius with Digital Temperature Controller and Display, Minimum of 4 adjustable Shelve/Rack Recommended Make: BLUE STAR |
| 116 | Supply and Installation of 160- 190 litre single door refrigerator, direct-cool model with a minimum 3-star BEE rating and stabilizer-free operation. It shall use eco-friendly refrigerant (R600a) and have a high-efficiency, low-noise compressor. The unit shall include toughened glass shelves, a vegetable crisper, bottle storage for 2L bottles, an internal freezer compartment, and a removable anti-bacterial gasket. It shall operate on 230V, 50Hz AC and include standard accessories such as an ice tray and egg tray. The refrigerator shall have 1-year comprehensive warranty and 10-year compressor warranty, with BIS certification. |
| 117 | Air Conditioning System |
| 118 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation up to 3 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1 TR 3 Star rated (inverter type AC) as per BEE |
| 119 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation up to 4 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1.5 TR 3 Star rated (inverter type AC) as per BEE Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail