| 1 | DSR Item No. 28.2.1Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, (As per Complete Item No. 1 of the DNIT). |
| 2 | Two Loop Panel. |
| 3 | Supply, installations, testing and commissioning of intelligent multisensor detector with integrated fault isolator and isolator base. The intelligent multi criteria detector shall have integrated fault isolator/ fault isolator base as per NFPA style 7 to make ensure complete system working without losing any detector in case of cable fault. Be an addressable device that is designed to monitor a minimum of photoelectric and thermal technologies in a single sensing device. (As per Complete Item No. 1 of the DNIT). |
| 4 | DSR Item No. 28.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required |
| 5 | DSR Item No. 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 6 | DSR Item No. 28.3.2 Supplying,installation,testing&commissioningof1.5/3/6W ceilingspeakercompleteasrequired |
| 7 | DSR Item No. 28.2.11 Supplying, installation, testing & commissioning of addressable phone control module complete as required. |
| 8 | DSR Item No.28.3.1 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 9 | DSR Item No.28.3.9 Supplying, installation, testing & commissioning of Voice command keypad6 zone, withmicrophone assembly complete as required. |
| 10 | DSR Item No. 28.3.7 Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 11 | DSR item no.26.1.1 Online UPS - Input supply: Single Phase, Output Supply: Single Phase,Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, (As per Complete Item No. 10 of the DNIT). |
| 12 | 2 KVA |
| 13 | DSR Item No. 28.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 14 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 15 | DSR Item No. 28.5.2 Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/ 1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring& FRLS outer sheath complete as required. |
| 16 | DSR Item No. 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of Surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 25 mm |
| 18 | S/I/T/C of fire exit sign board illuminated made from etched sheet with LED illumination and all electrical accessories included battery and battery charge etc. on ceiling/ wall mounted (with logo & exist arrow) Make-Glowline/ HHE/ Ravel/ Honeywell |
| 19 | Supply installation testing and commissioning of 2X12 watt wall mounted Industrial Double Beam emergency LED light with exit sign board. The fitting should have CRCA steel housing, 50000 burning hours, battery of 4 to S All for emergency backup of 4 to 5 hours. (As per Complete Item No. 15 of the DNIT). Please Enable Macros to View BoQ information |