| 1 | Item Description |
| 2 | Demolishing cement concrete manually / bymechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge: Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 3 | Demolishing brick work including stacking ofserviceablematerialsanddisposal ofunserviceablematerialswithall liftsanduptoa leadof 50metc.complete as per direction of the Engineer- in-charge: In cement mortar. |
| 4 | Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge. |
| 5 | Dismantling old plaster or pointing, raking out joints,cleaning and preparing the surface for re-plasteringor re-pointing including disposal of rubbish to thedumping ground with all leads and lifts etc.completeas per direction of the Engineer- in-charge. |
| 6 | 15mmcementplasterontheroughsideofsingleorhalfbrick wall of mix: Cement mortar 1:3 (1 cement : 3 fine sand) |
| 7 | Providing corrugated G.S. sheet roofing includingvertical/curved surface fixed with polymer coated Jor L hooks, bolts and nuts 8 mm diameter withbitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead and including a coatof approved steel primer and two coats of approvedpaint on overlapping of sheets complete (up to anypitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever requiredetc. complete as per direction of Engineer-in-charge. 0.63mm thick with zinc coating not less than 275gm/m2 |
| 8 | Providing ridges or hips of width 60 cm overall widthplain G.S. sheet fixed with polymer coated J or L hooks,bolts and nuts 8 mm dia G.I. limpet and bitumenwashers etc. complete as per direction of Engineer-incharge. 0.63mm thick with zinc coating not less than 275gm/m2 |
| 9 | Providing and fixing flat pressed 3 layer mediumdensity particle board or graded particle board (Grade I)IS: 3087 marked in ceiling with necessary nails etc.complete as per direction of Engineer-in-charge. (framework to be paid separately): 12 mm thick |
| 10 | Providing and laying 1st class quality vitrified floor tilesin different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% andconforming to IS: 15622- 2017, of approved make, in allcolours and shades, laid over 20mm thick cement mortar1:4 (1 cement : 4 fine sand), jointing with grey cementslurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc. all complete asper direction of the Engineer-in-charge.. Soluble Salt Stainfree vitrified tiles (Glossy) Size of tile 600 mm x 600 mm |
| 11 | Providing and fixing 1st class quality ceramic glazed walltiles conforming to IS : 15622- 2017 (thickness to bespecified by the manufacturer) of approved make in allcolours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12mm thick bed of cement mortar 1 : 3 (1 cement : 3 finesand) jointed with ordinary cement slurry includingpointing with white cement mixed with pigment ofmatching shade etc. all complete as per direction of theEngineer in-charge. 600 mm X 300 mm in all shades and design |
| 12 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate40 mm nominal size) |
| 13 | 6.12 Half brickmasonryworkwith first class bricks insuperstructureuptofloor five level includingcostofall materials as required complete: In cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 14 | Painting with synthetic enamel paint, having VOC(Volatile Organic Compound) content less than 150grams/ litre, of approved brand and manufacture,including applying additional coats wherever required toachieve even shade and colour [Payment shall be madeafter submission of Test Certificate issued by theManufacturer]. Two coats |
| 15 | Painting with oil type wood preservative of approvedbrand and manufacture [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer]: New work (two or more coats) |
| 16 | Painting on G.S. sheet with synthetic enamel paint ofapproved brand and manufacture of required colour togive an even shade [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer] : New work (two or more coats) including a coat ofappropriate steel primer but excluding a coat of mordantsolution |
| 17 | Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture[Payment shall be made after submission of TestCertificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 18 | Distempering with 1st quality acrylic distemper (readymixed) having VOC content less than 50 grams/ litre, ofapproved brand and manufacture to give an even shade[Payment shall be made after submission of TestCertificate issued by the Manufacturer] : New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 19 | Finishing with Deluxe Multi surface paint system forinteriors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submissionof Test Certificate issued by the Manufacturer]: Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @ 0.75 ltr/10sqm of approved brand and manufacture. |
| 20 | Providing wood work in frames of false ceiling,partitions etc. sawn and put up in position : Local Teak Wood |
| 21 | Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m RCC M15 grade (using jhama brick aggregate)150mm x 150 mm concrete post placed every 3 m centre-tocentre founded in M15 grade cement concrete, 0.6 mbelow ground level, every 15th post, last but one end postand corner post shall be strutted on both sides and endpost on one side only and provided with 12 horizontal linesand 2 diagonals interwoven with horizontal wires, fixedwith GI staples, turn buckles etc. complete as per MoRDtechnical specification Clause 1705. |
| 22 | Boundary Pillar (with PCC M15 grade using jhama brick aggregate and reinforcement) Plain cement concrete M15 grade (using jhama brick aggregate and reinforcement) boundary pillar / local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Technical Specification Clause 1704. |
| 23 | Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means over areas (exceeding 30cm indepth, 1.5m in width as well as 10 sqm on plan) includingdisposal of excavated earth, lead upto 50m and lift upto1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 24 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate20 mm nominal size) |
| 25 | ProvidingandfixingM.S.grillsofrequiredpatterninframes of windows etc. withM.S. flats, square orround bars etc. all complete. Fixed to steel windows by welding. Please Enable Macros to View BoQ information |