Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 3 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 4 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 6 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing designation 125mm thick reinforced designation 75A brick work in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement0 all complete as per building specification and direction of E/I. |
| 9 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 12 | 1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 13 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size) |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 15 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 18 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 19 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 20 | Reinforced cement concrete work in beams, suspended flooring, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stai case plinth level up to floor five leve, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 22 | Foundation, fotting, bases of columns etc. for mass concrete |
| 23 | Suspended floors, roofs, landings, balconies and access platform |
| 24 | Lintels, Beams, Plinth Beam girders, bressumers and cantilivers |
| 25 | Columns, Pillars, Piers, Abutment, Posts and struts |
| 26 | Providing Toe steel reinforcement of 8mm dia to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) |
| 27 | 8 mm @ 30% |
| 28 | 10 mm @ 30% |
| 29 | 12 mm to 20mm @ 40% |
| 30 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 31 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 32 | Supplying, fitting and fixing 20mm dia M.S. Bar 1 meter long holding down bolt with nuts washers 100 X100 X6mm plate fitted and fixed with cement concrete (1:24) as per approved design all complete as per building specification and direction of E/I. |
| 33 | Labour for fabricating, erecting, hoistion and fixing in position structrral steel work in R.S. Joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, stair case, or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding ( machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I. |
| 34 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 35 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 36 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 37 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 38 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 39 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 40 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 41 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 42 | Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I. |
| 43 | Providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding , curing and taxes all complete as per building specification and direction of E/I. |
| 44 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 45 | Providing two coats of synthetic enamel paint of apporoved shade and make over steel surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 46 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 47 | Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:- |
| 48 | Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent. |
| 49 | Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 50 | 1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured. |
| 51 | 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical |
| 52 | Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370) |
| 53 | Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" |
| 54 | Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years. |
| 55 | Covering of treated surface with PCC :- Providing 50mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. to 3 including screening, shuttering and mixing cement concrete in mixer with admixture in integral water proofing and placing in position, skirting curing, taxes and roaylty all complete as per building specification and directions of E/I. Panels that has been left should be casted next day. There should be 6mm gap between Panels Brand-Sika-plastocrate plus, MYK proof WP 10, Fosroc-Conplast X 4211C, Dr. Fixit Pidproof LW+ or equivalent. |
| 56 | Providing and filling of 6mm thick Groove between 25mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of E/I. (with 18% GST) Brand - Sika-Polysulphide, Forsoc-thioflex 600, Dr. Fixit Pidiseal PS (42P, MYK Seal PS or Equivalent. |
| 57 | Providing 19mm thick water proof cement plaster (1:3) with clean coasre sand of F.M. 1.5 with integral water proofing compound Liquid @ 125ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X4211C, Dr. Fixit Pidiproof LW+ or Equivalent |
| 58 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 59 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Framesof cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be mouldedwith fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitablewooden block in all the three legs. The frame shall be covered with fiberglass from all sides. M.S. stay shall be provided at the bottom to steadythe frame. |
| 60 | Providing and fixing to existing door frames. - 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelleddoor shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturatedpolyester resin, moulded to 3 mm thick FRP laminate forforming hollow rails and styles, with wooden frame and suitableblocks of seasoned wood inside at required places for fixingof fittings, cast monolithically with 5 mm thick FRP laminatefor panels conforming to IS: 14856, including fixing to frames. |
| 61 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete. |
| 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 63 | 75 mm diameter |
| 64 | 110 mm diameter |
| 65 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 66 | Coupler 75 mm |
| 67 | 110 mm |
| 68 | 75 mm |
| 69 | 110 mm |
| 70 | Single tee without door 75 mm |
| 71 | 110 mm |
| 72 | Bend 87.5° 75 mm |
| 73 | 110 mm |
| 74 | Shoe (Plain) 75 mm |
| 75 | 110 mm |
| 76 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 77 | 110 mm |
| 78 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 79 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 80 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 81 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 82 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. - M.S. tube |
| 83 | Supplying and Fixing Gusset Plate |
| 84 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required. |
| 85 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 86 | Caraige of materials |
| 87 | Bricks Lead = 8km (7p+1k) |
| 88 | Sand lead = 10 km |
| 89 | Stone chips lead = 22 km |
| 90 | Stone metal lead = 22 km |
| 91 | Local Sand - 3 Km |
| 92 | Fly Ash Brick |
| 93 | Providing and fixing Gun metal full way valve of approved quality, all complete as per specification and direction of E/I. |
| 94 | (c) 25mm dia and weight not less than 500gms. |
| 95 | (d) 32mm dia and weight not less than 700gms. |
| 96 | Cutting chhajja or corince for laying G.I. pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortor (1:4) as per specification and direction of E/I. |
| 97 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. |
| 98 | 125mm thick wall |
| 99 | 250 mm thick wall |
| 100 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.- Mirrors of 6mm thick glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror- 600mm x 450mm size |
| 101 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. |
| 102 | 50x 0.500 x 0.600 |
| 103 | Labour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.150mm |
| 104 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 105 | Supplying and fixing NP2 Hume pipe etc. (150mm dia) |
| 106 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I. |
| 107 | 580mm long - With 10.0 liter low level PVC cistern |
| 108 | Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I.With 'P' trap - 12.5 lit low level PVC Cistern |
| 109 | Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of Hindustan \\"Parry\\" or any other approved I.S.S. Make with 5 liters capacity C.I. Automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. bracket, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.- (a) Flat back or standing corner (600mmX350mm) |
| 110 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 111 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 112 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 113 | Flexible Pipe - 40 mm |
| 114 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 115 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal Work - Exposed on Wall |
| 116 | 25 mm nominal dia Pipes |
| 117 | 32 mm nominal dia Pipes |
| 118 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed Work |
| 119 | 15 mm |
| 120 | 20 mm |
| 121 | Providing and fixing PTMT grating of approved quality and colour. |
| 122 | Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 123 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 124 | With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 125 | Special type C.P. Bath room Fitting for V.I.P.Buildings(JAL, Jaquar, Mark or Equivalent) |
| 126 | Pillar cock (Long neck) |
| 127 | Bib cock (Long Thread) |
| 128 | Bib cock (2 Way) |
| 129 | Angular Stop Cock |
| 130 | Pressure Adjustable Shower with revolving joint (Health Façade) |
| 131 | soap dish |
| 132 | Wiring for light/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit with Modular Plate suitable G.I. box and earthing the point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required. |
| 133 | Group A |
| 134 | Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required |
| 135 | Wiring for Curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required |
| 136 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 137 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 138 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 139 | 5/6 amps, one way switch |
| 140 | 15/16 amps, one way switch |
| 141 | 5/6 amps, 3 pin socket outlet |
| 142 | 15/16 amps, 6 pin socket outlet |
| 143 | S/F Modular boxes, base & cover plate - Supplying and fixing following size/modulaes G.I. box along with modular base & cover plate for modular switches in recess etc. as required. |
| 144 | 1 or 2 (78mm x 78mm x 45mm) |
| 145 | 4/5 module (78mm x 140mm x 50mm) |
| 146 | I.T.C of exhaust fan up to 450mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc. as required |
| 147 | S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 148 | S/F 6 amp. To 32 amp rating 240 volt 10KA \\"B\\" Curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. a srequired.6/32 amps, single pole \\"B\\" series |
| 149 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 150 | 20W LED Street light |
| 151 | S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 152 | 20/22W LED Tube Light |
| 153 | 9/10Watt LED Bulb |
| 154 | 12\\" (300mm) metal exhaust fan |
| 155 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressure and equipmentsas well as fule, lubricants and cost of transportation of rig machine and other vehical up to Site. |
| 156 | (a) From 0.00 M to 50.00 M below G.L. |
| 157 | (b) From 51.0 M to125.00 M |
| 158 | (c) From126.0 M to150.00 M |
| 159 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 160 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 161 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 162 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 163 | Supplying Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP |
| 164 | Supplying Fully automatic star delta starter to operate induction motor working on 415V, 3 phase, 50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc. complete starter with original sheet steel encloser as per IS : 3914F.A.S.D Starter - 10 H.P |
| 165 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 166 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal dia Pipes |
| 167 | Supplying & Fixing AMRUT ENERGY PRIVATE LIMITED--AMRUT ENERGY PRIVATE LIMITED Model III Lithium Ferro phosphate battery (for Model III & IV) 12 V, 20 Ah for Model II AMRUT ENERGY PRIVATE LIMITEDUR Unregistered Brand Manufactured by: AMRUT ENERGY PRIVATE LIMITED (24 WATTS STREET LIGHT), Product id: 5116877-23259286031, Model of Solar Street Lighting System Model III Power Output of PV Module 40 Wp (for Model III) Type of Battery Lithium Ferro phosphate battery (for Model III & IV) Battery Capacity 12 V, 20 Ah for Model II LED Rating White LED, 7 W (Max.) Height of Pole 5 meters above the ground level for Model III & IV, GENERIC Description of Stores Solar street lighting system (SLS) is an outdoor lighting unit used for illuminating a street or an open area Conformity of the Specification As per MNRE specifications attached Attached specification has been seen and understood Yes Solar Street Lighting System Consists of SPV Module, Luminaire, Storage batteryStorage battery, Control electronics, Inter-connecting wires/cables, Module mounting pole including hardware and battery box Model of Solar Street Lighting System Model III PV MODULE Power Output of PV Module 40 Wp (for Model III) Type of PV Module Crystalline silicon solar cells BIS CRS Compliance for PV Module as per IEC 61215 Edition II / BIS 14286 from NABL or IECQ accredited Laboratory BATTERY Type of Battery Lithium Ferro phosphate battery (for Model III & IV) Battery Capacity 12 V, 20 Ah for Model II Battery Conforming to BIS standard / International Standards LIGHT SOURCE LED Rating White LED, 7 W (Max.) Minimum Light Output 16 LUX Colour Temperature (in K) 5500 to 6500 Lamps Housed in an Assembly Suitable for Outdoor, Water proof , IP65 ELECTRONICS Indicators Green for charging is taking place and Red for Load cut off condition Availability of No Load Protection Yes Availability of Battery Overcharge and Deep Discharge Protection Yes Provision of Short Circuit Protection Yes. Provided with Fuse Availability of Reverse Flow of Current Protection through PV Modules Yes Availability of Battery Reverse Polarity Protection Yes Load Reconnect at 80% of the battery capacity status MECHANICAL COMPONENTS Material of Pole G.I. Pipes Height of Pole 5 meters above the ground level for Model III & IV Provision to hold the luminaire on pole Yes Material of Battery Box for Housing the Battery Acid proof and corrosion resistant Metallic box with locking arrangement CERTIFICATIONS Warranty for Street Lighting System (including the battery) (in Years) 5 Minimum Warranty For PV Modules (in Years) 25 Warranty Card Provided Yes Provision of Operation and Maintenance Manual Yes. Provided as per MNRE Specn., Agree to Furnish Name and Address of the Contact Person for Repair and Maintenance in case of non-functionality of the Solar Street Lighting System Yes. Agreed. All Other Technical Requirements as per MNRE specification Agreed to Furnish LM-80 Report For LEDs used in the Lighting System Yes Availability of test reports from Central Govt Lab/NABL accrediated lab/ILAC accrediated lab to prove conformity of the specification Central Govt. Lab Test report number and date if claimbed \\"Yes\\" If No write NA NA Name and addres of lab (If No test reports write NA) NA Agreed to furnish all test reports and certificates to buyer on demand Yes |
| 168 | Pole 5 meters above the ground level for Model III & IV Provision to hold the luminaire on pole Yes Material of Battery Box for Housing the Battery Acid proof and corrosion resistant Metallic box with locking arrangement CERTIFICATIONS Warranty for Street Lighting System (including the battery) (in Years) 5 Minimum Warranty For PV Modules (in Years) 25 Warranty Card Provided Yes Provision of Operation and Maintenance Manual Yes. Provided as per MNRE Specn., Agree to Furnish Name and Address of the Contact Person for Repair and Maintenance in case of non-functionality of the Solar Street Lighting System Yes. Agreed. All Other Technical Requirements as per MNRE specification Agreed to Furnish LM-80 Report For LEDs used in the Lighting System Yes Availability of test reports from Central Govt Lab/NABL accrediated lab/ILAC accrediated lab to prove conformity of the specification Central Govt. Lab Test report number and date if claimbed \\"Yes\\" If No write NA NA Name and addres of lab (If No test reports write NA) NA Agreed to furnish all test reports and certificates to buyer on demand Yes |
| 169 | Add 18 % GST (in Basic Rate must fill 12) |
| 170 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail