| 1 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 2 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 3 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 4 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 5 | M&L for second class hardwood, scantlings, wrought, fixed in unframed work complete as specified and directed. |
| 6 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etccomplete all as specified and directed |
| 7 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed. |
| 8 | S&F galvanised steel wire netting 0.71 mm dia and 25 mm size of mesh for lathing, fixed with tinned of wire staples to wooden frame in all including all laps, cutting and waste complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed. |
| 10 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement complete all as specified & directed. |
| 11 | M&L for preparation of plastered surfaces of walls and applying thin layer of wall care putty of 1 to 2mm thick and finally applying two coats of distemper oil emulsion over primer complete all as specified and directed. |
| 12 | M&L for applying thin layer of wall care putty of 1 to 3mm thick complete all as specified and directed. |
| 13 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 14 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 15 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directd by engr-in-Charge. |
| 16 | M&L for brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 17 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 18 | S & F framrd work as in in door or gates of angle or other section with gusset plates, tailes braces etc complete drilled for fixing of steel sheeting or other covering . Doors etc to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fitting, water tank stage ( exclusive of steel sheeting or othercovering running rails and guide and hanging also fastering and fixing complete, complete all as specified and diected. |
| 19 | Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed. |
| 20 | Supply & Fixing plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 21 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long |
| 22 | M & L preparation of New or previously untreated steel surfaces and applying one coats of synthetic enamel paint over a coat of red oxide to surfaces of any description not otherwise described over 10cm width or girth complete all as specified & directed. |
| 23 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed. |
| 24 | S & F 605x605mm Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. |
| 25 | M & L for 4 mm thick non asbestos fibre cement decorative ceiling boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws etc, complete all as per manufacturer instructions |
| 26 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge. |
| 27 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed by the Engineer-in-Charge. |
| 28 | Taking down Shutters of any description exc 1 sq. m and nexc 2 sqm same opening complete all as specified and directed. |
| 29 | Taking down Shutters of any description n' exc 1 sq. m in same opening complete all as specified and directed. |
| 30 | S & F for aluminum powder coated (powder coated of required colour) three track (2 Nos Glazed shutter & 1 Nos Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.75 x 1.50mm (Section of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified |
| 31 | S & F powder coated aluminium (minimum thickness of powder coating 50 micron) works for doors , windows and ventilators and partition (fixed portion ) with extruded built up standered tubelar section / appropriate Z section and other section of approved make confirming to IS 733 and 1285 fixing with dash fasterner of requered dia and size including necessary filling up the etc. Aluminium section shall be be smooth rust fire , straight mitred and jointed mechanically wheever required including cleat angle alluminium snap beading for glazing / paneling C.P brass / stainless steel screw all complete as per architectural drawing and the direction of Engr-in-charge. |
| 32 | S&F Anodised aluminium door shutter aluminium section weiging 0.55 kg /m including necessary joining cleats glazing clips rubber neuprene packing handle 2Nos in each door , hinges anodised aluminium snap beading screw etc. complete all as specified & directed. |
| 33 | M&L 5.50 mm Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane |
| 34 | S & F 2nd class Plain, solid straight chowket and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete |
| 35 | S&F 30 mm thick, laminated moulded Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats of complete all as specified & directed. |
| 36 | S & f 12mm Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed. |
| 37 | S & F Double action floor spring hydrocally regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heacy body and fixed complete all specified and directed. |
| 38 | S&F 100mm size butt hinges, medium weight, cold rolled mild steel & fixed complete all as specified & as directed. |
| 39 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete all as specified and as directed. |
| 40 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 41 | S&F 300mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 42 | S&F Floor door stopper doubled leged of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor. |
| 43 | S&F MS chromium plated curtain rod 25 mm dia , with and including MS chromium plated decorative round finials on either end provide a visually balanced appearance including MS chromium plated brackets fixed to wall with 30 mm wooden steel screws and PVC rawl plug, anchors, and installation as in repair complete. |
| 44 | M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 45 | M & L Plain fillets. of 2nd class soft wood of square, rectangular or triangular in section, clean sawn, secured with nails or brads.Exc 13 & nexc 25 sqcm |
| 46 | M & L Solid PVC Wall Lining consisting of 5mm thick of wood grain printed on single side PVC sheet and other side balancing with plain colour inclusive of solvent cement and fixing at site on frame as per specifications and drawing |
| 47 | Dismantling of water tanks and removing to store Exc 250 & nexc 500 ltrs |
| 48 | S & F 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Par I |
| 49 | S & F in repairs 20mm gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 50 | Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 20mm dia complete all as specified and directed. |
| 51 | S&F 20mm dia bore of pipes, medium grade, galvanised iron, with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified & directed.. |
| 52 | Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 15mm dia complete all as specified and directed. |
| 53 | S&F 15mm dia bore of pipes, medium grade, galvanised iron, with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified & directed.. |
| 54 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 55 | M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in mass concrete, sub base , etc complete all as specified and directed. |
| 56 | Dismantling of floor, hearth or wall tiling including cement mortar bedding(but not backing) , removing serviceable tiles to store and rubbish off the premises |
| 57 | M&L joint free non-skid coloured ceremic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc incl screed bed set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles including 15mm thick screed bed in CM 1:6. |
| 58 | M&L joint free non-skid coloured ceremic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Vertical surfaces etc rendering 10mm thick screed bed in CM 1:4 on fair faces of brick work or concrete surfaces complete. |
| 59 | M&L for 15mm thick Granite (of any type) work (table rubbed and polished) in steps, Jambs, window cills cooking platforms, WHB plateform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with sahade of granite complete |
| 60 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge. |
| 61 | Refixing only the same of serviceable copper point wiring (light, fan, socket or power) obtained from item no 60 above complete with minimum repair of PVC casing capping /conduit if required at site complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 62 | Refixing only the same of serviceable copper point wiring (light, fan, socket or power) obtained from item no 60 above complete with minimum repair of PVC casing capping /conduit if required at site complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |