| 1 | M & L for preparation of plastered or unplastered old decorated surfaces of walls all as specified and filling cracks/hole by applying wall putty where ever required (multipurpose mixer will be used for uniform and proper mixing of putty) and applying one coat of distemper oil emulsion white or coloured by auto roller complete incl removal of nails etc and grinding where necessary all as specified & directed by Engr-in-Charge. (Note:- work can carried out upto fourth storey) |
| 2 | M & L for preparation of plastered or unplastered old decorated surfaces of walls all as specified and filling cracks/hole by applying walls and ceiling putty (multipurpose mixer will be used for uniform and proper mixing of putty) and applying two coats of distemper oil emulsion white or coloured by auto roller complete incl removal of nails etc and grinding where necessary all as specified & directed by Engr-in-Charge. (Note:- work can carried out upto fourth storey) |
| 3 | M & L for preparation of old decorated surfaces of walls and cornices and applying one coat of acrylic emulsion paint (Apex) including necessary wall putty as required of approved colour/pattern upto 4th storey and hanger including necessary scaffolding all as specified and directed by Engineer-in-Charge. Note:-work may be carried out in patches at different locations upto fourth storey/hanger |
| 4 | M & L for preparation of old decorated surfaces of walls and cornices and applying two coat of acrylic emulsion paint (Apex) including necessary wall putty as required of approved colour/pattern upto 4th storey and hanger including necessary scaffolding all as specified and directed by Engineer-in-Charge. Note:-work may be carried out in patches at different locations upto fourth storey/hanger |
| 5 | M & L for preparation old decorated plastered and unplastered surfaces of ceiling and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying two coat of white/colour wash complete all as specified and directed by Engineer-in-Charge. Note:-work can carried out upto fourth storey/hanger |
| 6 | M & L for preparation of old painted wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge. |
| 7 | M & L for preparation of old painted steel surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge. |
| 8 | Taking down cement or cement lime plaster of any description on bricks wall etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed by Engineer-in-Charge |
| 9 | M&L for 12mm thick rendering in cement mortar (CM1:4) for external wall surface mixed with WPC as per manufacturer instructions finished even & fair as a whole or in patches complete all as specified and directed. |
| 10 | M&L for 10mm thick rendering in cement mortar (CM1:6) for internal wall surface as per manufacturer instructions finished even & fair as a whole or in patches complete all as specified and directed. |
| 11 | M&L for 5mm thick rendering in cement mortar (CM1:4) for ceiling surface as per manufacturer instructions finished even & fair as a whole or in patches complete all as specified and directed. |
| 12 | M&L for preparing new plastered Surfaces of walls and cornices and applying two coat of acrylic emulsion paint (Apex)over a coat of primer of approved colour/pattern upto 4th storey and hanger including necessary scaffolding all as specified and directed by Engineer-in-Charge. Note:-work may be carried out in patches at different locations upto fourth storey/hanger |
| 13 | M&L for Preparing new surfaces of walls applying two coat of Oil Bound Distemper over a priming coat including providing putty of 1 mm thickness over plastered surfaces to prepare surface even and smooth complete all as specified and directed. |
| 14 | M & L for preparation newly plastered surfaces of ceiling and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying three coats of white complete all as specified and directed by Engineer-in-Charge. Note:-work can carried out upto fourth storey/hanger |
| 15 | M & L for preparation old decorated stone, concrete, asbestos cement sheet or plaster surfaces of any description not otherwise described, over 10 cm width or girth and applying a coat of floor coat emulsion paint (INDIGO) complete all as specified and as directed by Engineer-in-Charge.Note : Floor coat emulsion paint may be applied in two coat as per the ground requirement and directions |
| 16 | M & L for finishing walls with textured paint of required shade of royal play with different tools that added texture to a plain surface as per user requirement including priming coat of primer applied @ 2.20kg/10 sqm (Two or more coats applied) as per site requirement complete all as specified. |
| 17 | Supply only water proofing compound complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L 19-20mm granite stone slabs of approved shade, external edges moulded half rounded, bedded in cement screed 15mm thick in CM 1:6 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the stone including grinding, polishing, dismantling floor and screeding etc complete all as specified. |
| 19 | M&L for ceramic coloured tiles as in floors 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm (400mmx400mm x 7mm thick) set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) Incl dismantling floor and screeding etc complete all as specified. complete all as specified and as directed. |
| 20 | M&L for non skid ceramic coloured tiles as in floors 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm (300 mmx300mm x 7mm thick) set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6), including dismantling floor and screeding etc complete all as specified and as directed. |
| 21 | M&L for glazed ceramic colour tile in area size 450mmx300mm x7mm thick set and jointed in neat cement slurry and pointed in coloured cement on vertical surfaces such as in dado/skirting etc over and including 10 mm thick rendering in cement mortar (1:4), including dismantling floor and screeding etc complete all as specified. |
| 22 | M & L for servicing/easing steel windows shutters of size not exceeding 2 Sqm each including cleaning scrapping hacking oiling replacing welding broken hinges making good disturbed portion painting all as specified as directed |
| 23 | Easing of wooden door shutters/Almn door/PVC door shutter/ Almn window (One unit shall comprising of one window/CB/ Showcase/irrespective of number of leaves) for properly closing/opening tightening of hinges or changing the position of hinges adjustment of tower bolts sliding bolt etc. complete all as specified |
| 24 | Hacking out old broken glass (any thickness, size, quality or description)from metal frame incl punching or drilling out old glazing pin and providing and fixing new plain or pin headed glass 3mm thick not exc 0.50 Sqm each complete all as specified |
| 25 | M&L for jointing and testing galvanized iron tube 15 mm dia, medium grade with all fittings such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floors including taking down existing tubing etc complete all as specified |
| 26 | S&F in repairs PTMT bib taps 15 mm dia bore complete all as specified |
| 27 | S&F in repairs PTMT stop valve 15 mm dia bore with long shank complete all as specified |
| 28 | S&F in repairs PTMT angle stop valve 15 mm dia bore complete all as specified |
| 29 | S&F in repairs PTMT shower 15 mm dia bore complete all as specified |
| 30 | S&F in repair vitreous china squatting pan “ORISSA PATTERN” size 580mmx440mm ‘white’ with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe anti syphonage pipe etc and removing old IWC outside MoD land complete all as specified |
| 31 | S&F PVC in repairs PVC flushing cistern 10 ltrs capacity, low level, white with inlet, ball valve, float and handle including brackets complete all as specified |
| 32 | S&F in repair vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling, waste pipe and including PTMT pillar tap 15mm, waste fitting and union, removing old WHB outside MD land complete all as specified and directed |
| 33 | Supply only PVC connection 15 mm dia and 450 mm long with both end brass fly nut complete all as specified |
| 34 | S& F in repairs white colour triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and jointed in position all as specified in SSR Part-I (500 ltr capacity) including disconnecting existing tank and providing all necessary fittings for connecting with pipe line, metal lockable cover. |
| 35 | S& F in repairs white colour triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and jointed in position all as specified in SSR Part-I (1000 ltr capacity) including disconnecting existing tank and providing all necessary fittings for connecting with pipe line, metal lockable cover. |
| 36 | S&F in repair framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balsters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 grade or Fe-310-0 including fixing with fastener bolts/welding as per site requirement complete all specified |
| 37 | S&F in repair welded steel wire fabric exc 4Kg per Sqm welded to steel section at any position complete all as specified |
| 38 | M & L for preparation of new steel surfaces exc. 10cm in width and girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, all as specified. |
| 39 | S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mmx160mm, also including waste coupling and waste pipe complete all as specified |
| 40 | S&F in repair kitchen plate rack of size 600x750 mm made of Stainless Steel 1 mm thick fixed on the wall with brackets complete all as specified |
| 41 | S & F in repairs aluminium anodised curtain rods 20 mm dia with brackets and end knobs complete all as specified |
| 42 | S & F in repairs aluminium anodised tubular towel rods 20 mm dia D type 60cm long complete all as specified |
| 43 | S&F in repairs Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing including taking down existing door frame with shutters and as directed |
| 44 | S&F in repairs for 30 mm thick factory made solid panel PVC door shutter confirming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 gauge thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings |
| 45 | S & F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 |
| 46 | S & F 150 mm size aluminium handles, cast type anodised and fixed. |
| 47 | S & F 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 48 | S & F Aluminium Anodized powder coated aluminium frame for doors, windows, ventilators, partition wall with one or more rebates, any number of tracks including joining cleat for fixing etc complete all as specified. (thickness of powder coating is 50 micron) |
| 49 | Providing and fixing powder coated, window/ventilator with sliding glazed shutter along with stainless wire mesh shutter along with aluminium frame of 1.55mm thick, tinted glass of 5.50mm thick and 7mm thick aluminium anodised grill fixed to frame with locking arrangement, handles fixed complete and finished with metal paste on gap of the surface with necessary jointing clips, aluminium snap beading, screws, click handle etc complete fixed to frame in contact with brick work and making good disturbed portion of jamb, cill etc all as directed and specified and approved. |
| 50 | S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and fixed with tinned tacks to galvanised wire staple |
| 51 | M & L for preparation of old plastered surfaces of walls and applying two coat of Oil Bound distemper of approved tint, including providing putty of 1 mm thickness over plastered surfaces to prepare surface even and smooth complete all as specified and directed. Please Enable Macros to View BoQ information |