| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x 1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required.(TSR (IE)2021 SL.No.201) |
| 2 | Short Point |
| 3 | Medium Point |
| 4 | Long Point |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required.(TSR (IE)2021 SL. No. 203) |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required.(TSR (IE)2021 SL. No. 204) |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.(TSR (IE)2021 SL.No.205) |
| 8 | 2 x 1.5 sq mm |
| 9 | 2 x 2.5 sq mm |
| 10 | 2 x 6 sq mm |
| 11 | 4 x 6 sq mm |
| 12 | 4 x 16 sq mm |
| 13 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required.(TSR (IE)2021 SL. No. 503) |
| 14 | 1 x 1.5 sq mm |
| 15 | 2 x 1.5 sq mm |
| 16 | 2 x 2.5 sq mm |
| 17 | 2 X 4 sq.mm |
| 18 | 4 x 6 sq mm |
| 19 | 4 x 16 sq mm |
| 20 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mm x 6mm including accessories with masonry enclosure of CI cover plate size 12\\" x 12\\" having locking arrangement including CC works etc as required. (TSR (IE)2021 SL.No.717) |
| 21 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.( TSR (IE) 2021 SL.No.706) |
| 22 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required.(TSR (IE)2021 SL.No.710) |
| 23 | Supplying and installation of Switch disconnector fuse unit (main switch ) of the following ratings with all accessories including necessary connection etc. as required. (TSR (IE)2021 SL.No.1202) |
| 24 | 63 amps 415 volts TPN main switch (rewireable) |
| 25 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required. (TSR (IE)2021 SL.No.1201) |
| 26 | 63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330mm x 280mm x 100mm):- |
| 27 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/ TP/ TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(TSR (IE)2021 SL.No.1208) |
| 28 | 2 way SPN MCB DB (single door) |
| 29 | (2+10) / 12 way SPN MCB DB (double door) |
| 30 | 8 way horizontal TPN MCB DB (Double door) |
| 31 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required. (TSR (IE)2021 SL. No. 1215) |
| 32 | 6 to 32 amps SP MCB |
| 33 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required. (TSR (IE)2021 SL. No. 1217) |
| 34 | 40 amps DP isolator |
| 35 | 40 amps FP isolator |
| 36 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required.(TSR (IE)2021 SL.No.609) |
| 37 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 70 KA (3P+N) |
| 38 | Catridge for Surge Protection Device (SPD) (Type-2) with Imax 70 KA (1P+N/3P+N) |
| 39 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt)(TSR(IE)2021 SL. No. 1101) |
| 40 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp) |
| 41 | Surface mounted box type batten suitable for double 18/20 watt integrated LED tube lamp (without lamp) |
| 42 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser. |
| 43 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/ diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt)(TSR(IE)2021 SL. No. 1102) |
| 44 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 45 | Supplying and fixing of following LED Tubes, retrofit bulbs/ lamps for LED luminaries including necessary connection etc. as required.(TSR(IE)2021 SL. No.1103) |
| 46 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt) |
| 47 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink |
| 48 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required.(TSR(IE)2021 SL.No.1501) |
| 49 | 40 mm dia |
| 50 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mm x 25mm x 5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required. (TSR (IE) 2021 SL.No.1502) |
| 51 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. (TSR (IE)2021 SL.No.1505) |
| 52 | Supplying & fixing of 40mm x 6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required. (TSR (IE)2021 SL.No.1506) |
| 53 | Drawing of armoured/un-armoured cable with proper saddeling etc as required.(TSR (IE)2021 SL.No.1511) |
| 54 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required.(TSR (IE) 2021 SL.No.816) |
| 55 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required.(TSR (IE) 2021 SL. No. 817) |
| 56 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required.(TSR (IE)2021 SL.No.821) |
| 57 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required.(TSR (IE)2021 SL.No.831) |
| 58 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2 x 1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/ minimum service value 4.0 m3/min/W)(TSR (IE)2021 SL.No.802) |
| 59 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc. as required. (TSR (IE)2021 SL. No. 1303) |
| 60 | 3 core 2.5 Sq mm |
| 61 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes.(TSR(IE)2021 SL.No.1402) |
| 62 | 2.5 sq.mm |
| 63 | 4 sq mm |
| 64 | 6 sq mm |
| 65 | 16 sq mm |
| 66 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable.(TSR(IE)2021 SL.No.1405) |
| 67 | 1.5 sqmm - 4 sqmm Cable |
| 68 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required.(TSR(IE)2021 SL.No.601) |
| 69 | 25 x 12mm |
| 70 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.(TSR(IE)2021 SL. No.602) |
| 71 | 25 mm dia |
| 72 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.(TSR(IE)2021 SL. No. 605) |
| 73 | 4 module plastic switch board |
| 74 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 75 | 4 module |
| 76 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.(TSR (IE)2021 SL.No.609) |
| 77 | 6/10 amps one way SP switch (1M) |
| 78 | 32 amps one way DP switch (2M) |
| 79 | 5 step fan regulator (2M) |
| 80 | Supplying and installation of secure zone 4 kg ABC powder fire Extinguisher gross weight 6.38 kg, empty weight 2.38 kg, can height 372 mm, diameter 150 mm, discharge time minimum 13 seconds, discharge mechanism - squeeze grip type range minimum 2 meters applicable on class A,B,C and electrically started fire, A rating- 2A, rating-55B, can contrast-mig welded, valve construction- forging & machining, external coating of can epoxy polyester powder coating, sheet metal thickness 1.60 mm, conforms to BIS standards, 5 years warranty (make ceasefire/ secure/fire shield) (Rate as per agreement no. 74/ EE/ IED/ AMB/2020-21) |
| 81 | Supplying, Installation of ESE Lightning Arrestor with 05.00 mtrs long GI mast with base plate 250 x 250 x 5 mm, Bakelite Insulator, Mounting Accessories (Stay wire , Pin fasten / Ring Fastener, U clamp etc.), Lighting Counter, Test Link, 03 nos Copper Rod Earthing with 3 bags 25kg earthing compound, 50 mtr long 70 sq. mm single core flexible copper cable etc. as required:- ( SABO make)(Rate as per analysis) Please Enable Macros to View BoQ information |