| 1 | DSR item No.1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | DSR item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | 3 x 4 sq. mm |
| 9 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | 25 mm |
| 11 | DSR item No. 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 12 | 5/6 amps switch |
| 13 | DSR item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | 15/16 A switch |
| 15 | 3 pin 5/6 A socket outlet |
| 16 | 6 pin 15/16 A socket outlet |
| 17 | DSR item No. 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | DSR item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 19 | 100 A,30KA,FPMCCB |
| 20 | 250 A,36KA,FPMCCB |
| 21 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single pole |
| 23 | Double pole |
| 24 | Triple pole and neutral |
| 25 | DSR item No. 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 26 | DSR item No. 8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.11) |
| 27 | 24 -26watt |
| 28 | DSR item No. 8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).(Please refer DNIT for complete specification of item no.12) |
| 29 | 100 watt |
| 30 | DSR item No.9.2 Brush Less Direct Current (BLDC) Fan without Remote (Please refer DNIT for complete specification of item no.13) |
| 31 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 32 | Supply, Erection, Testing and commissioning of the following items in existing LED fittings (Street light / flood light/ Post top lantern fitting) installed on wall/ existing pole upto 16 Mtr. Long in place of burnt out / defective material with the help of hydraulic ladder / Crain with bucket which shall be arranged by the firm at his own cost. The job includes cost of making connection with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge. The job also includes the cost of dismantling the burnt out / defective material. |
| 33 | S/E of Electronic Driver suitable for existing 100 watt LED fitting. The Driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic only. |
| 34 | S/E of Electronic Driver suitable for existing 150 watt LED fitting. The Driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic only. |
| 35 | S/E of Electronic Driver suitable for existing 200 watt LED fitting. The Driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic only. |
| 36 | Supply, Erection, Testing and commissioning of the following accessories after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. The job includes cost of making connections with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 37 | S/E of Electronic Driver suitable for existing 2’x2’/1’x4' LED panel type fitting. The driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic only. |
| 38 | S/E of electronic fan regulator step type socket type in the existing bakelite sheet including cutting the sheet and making connection etc. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge of the work. The fan regulator should be of Anchor (Penta)/ Havells (Reo)/ SSK make only. |
| 39 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Lauritz Knudsen (Entice) / ABB (Ivie) / Legrand (Myrius) / Crabtree (Athena)/ Norisys (Square series) only. |
| 40 | Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave plus)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points with the help of suitable rating copper wire. Please Enable Macros to View BoQ information |