| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed by Engr-in-charge. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. ( zinc coating 275) |
| 3 | S&F Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts or screws complete all as specified and directed |
| 4 | All as per item No 3 but plain sheets as in ridges and roof covering,eaves gutter all as specified and directed |
| 5 | S&F Plain, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and drected by Engr-in-Charge |
| 6 | S&F \\"except\\" Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts or screws complete all as specified and directed |
| 7 | S&F \\"except\\" Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed. ( zinc coating 275) |
| 8 | S&F in repairs position suspended false ceiling of 4mm thick Non asbestos(Designer) fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with grid system of grid size 600x600mm with anodised GI podwer coated (minimum thickness of powder coating 50 micron) frame work of main runner 35 x 25mm sheet thickness 0.7mm, cross Tee 35 x 25mm sheet thickness 0.7mm and wall angle 25 x 25mm x 0.7mm and using 4mm thick Non asbestos fibre cement building boards to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified, including dismantling wall and ceiling boards any thickness including cover fillets/ GI /Alumnium form work . complete all as specified and directed by Engr-in Charge. |
| 9 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed. |
| 10 | M&L for Rendering 15 mm thick in two layers (10+5) on fair faces or other than fair faces of brick work, concrete surface,stone masonary in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed by engr-in-charge.Note: Necessary additional dubbing if required will be done by contractor and nothing extra cost is admissible in this account.all as specified and directed. |
| 11 | M&L for Rendering 15 mm thick in two layers (10+5) on other than fair faces of brick work,stone masonary surface, concrete surface in cement mortar (1:4), finished even and fair without using extra cement complete all as specified and directed by engr-in-charge.Note: Necessary additional dubbing if required will be done by contractor and nothing extra cost is admissible in this account. |
| 12 | M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and directed. |
| 13 | M&L for preparing new plastered surface of wall and appying two coat of cement base paint mixed with silicon based water repellent compound by roller/brush complete all as specified & as directed by Engineer-in-Charge. |
| 14 | M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed. |
| 15 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, rubbish off the premises complete all as specified and directed |
| 16 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 17 | M&L for PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate in foundations, filling and mass concrete includingcomplete all as specified and directed. |
| 18 | M & L clean sawn second class soft-wood in frame work scantlings or frame work for false ceiling including dismantling all as specified and directed |
| 19 | M & L clean sawn 20 mm thick with butt joint second class soft wood boarding, supplied & fixed with nails in any situation (except flooring and skirting) including dismantling all as specified and directed. |
| 20 | Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil all as specified and directed by engr-in-charge |
| 21 | M&L 4 mm thick non asbestos cement plain building boards, fixed to timber framework with nails or screws including dismantling of board fixed in repair all as specified and directed |
| 22 | M & L second class soft wood exc 3sqcm not exc 6sqcm Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or screws and painting two coat of synthetic enamel paint over a coat of pink primer in repair including dismantling all as specified and directed |
| 23 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, in any situation all as specified and directed |
| 24 | M & L for brick work with sub class'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) all as spd and directed |
| 25 | All as per item no 24 above but except stone or brick built in CM (1:6) all as spd and directed |
| 26 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified |
| 27 | S&F structural steel work as in roof trusses (framed), trussed, purlins, rafter, crane gantries, rails, water tank staging, frame work chajja,or as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. & fastenings & heavy brackets framing including distance pieces, cleats etc. confirming to Fe 410-W (E-250 grade quality A) complete all as specified and directed by Engr-in Charge. |
| 28 | M&L for preparation of new steel and iron surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in Charge. |
| 29 | S&F for Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position all as specified in SSR Part-I with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line .including all accessories, and incl dismantling water tank of capacity exceeding 250 litres but not exceeding 500 litres and removing to stores, all as specified . |
| 30 | S&F for GI tubes medium grade 15mm dia, with all fittings and fixed complete to walls and ceiling or laid in floors, including taking up or down steel tubing of 15mm bore and connections complete all as specified and directed by Engr-in Charge. |
| 31 | S&F for GI tubes medium grade 20mm dia, with all fittings and fixed complete to walls and ceiling or laid in floors, including taking up or down steel tubing of 20mm bore and connections complete all as specified and directed by Engr-in Charge. |
| 32 | S&F in repair 15mm size gun metal globe or gate valves with iron wheel head, screwed both endsfor iron pipe and fixed complete all as specified and directed |
| 33 | S&F in repair 20mm size gun metal globe or gate valves with iron wheel head, screwed both endsfor iron pipe and fixed complete all as specified and directed |
| 34 | M&L for removing old paint by paint removers and cleaning with scrapers, any number of coats, any width or girth as in roof, not other wise specially described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in Charge. |
| 35 | Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 22 of tender doucments. Please Enable Macros to View BoQ information |