| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : |
| 5 | 1:3:6 (1 Cement : 3 pulverised sand : 6 graded stone aggregate 40 mm nominal size). |
| 6 | 1:4:8 (1 Cement : 4 pulverised sand : 8 graded stone aggregate 40 mm nominal size). |
| 7 | 1:2:4 (1 cement : 2 pulverized sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 8 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : |
| 10 | 1:1½:3 (1 cement : 1½ pulverised sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement : |
| 12 | 1:1½:3 (1 cement : 1½ pulverised sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ pulverised sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Centring and shuttering including strutting, propping etc. and removal of form for : |
| 15 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 16 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 20 | Thermo-Mechanically Treated bars of grade 500 D or more.. |
| 21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 22 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 23 | Structural steel work in single section fixed with or without connecting plat including cutting, hoisting, fixing in positing and applying a primming coat of approved steel primer all complete. |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 25 | Electric resistence or induction butt welded tubes. |
| 26 | Providing and fixing mild steel round holding down bolts with nuts and |
| 27 | Providing and fixing bolts including nuts and washers complete. |
| 28 | Cement concrete flooring 1:2:4 (1 cement : 2 pulverised sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 29 | 40mm thick with 20mm nominal size stone aggregate. |
| 30 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 31 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 32 | Ridges plain (500 - 600mm). |
| 33 | 12mm cement plaster of mix : |
| 34 | 1:4 ( 1 cement : 4 river sand ). |
| 35 | 6 mm cement plaster of mix : |
| 36 | 1:3 (1 cement : 3 fine sand) |
| 37 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 38 | Water thinnable cement primer |
| 39 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 40 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 41 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade. |
| 42 | Two or more coats on new work . |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 44 | Two or more coats on new work |
| 45 | Applying priming coat: |
| 46 | With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/steel works |
| 47 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 48 | Dark shade pigment using ordinary cement |
| 49 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 50 | 110 mm diameter |
| 51 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete |
| 52 | 110 mm |
| 53 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, includ ing jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 54 | Bend 87.5° |
| 55 | 110 mm bend |
| 56 | Single tee with door |
| 57 | 110x110x110 mm |
| 58 | Providing valleys of 90 cm wide overall in plain aluminium sheet, with nuts & washers etc. i/c making necessary connection with rain water pipes. |
| 59 | 1.00 mm thick |
| 60 | Providing and laying Hollow cement concrete block walling 150mm thick consisting of hollow block of size 400x150x200mm of mix 1:3:6 (1cement:3 Pulverised sand:6 graded stone aggregates of 10mm nominal size) laid in cement martar 1:6(1cement :6 sand). |
| 61 | ELECTRICAL WORKS |
| 62 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 63 | Group C |
| 64 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 65 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required |
| 66 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 67 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 68 | Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 69 | Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 70 | Supplying of prewired LED tube light T5 20W/22W (MAKE INTENSO LXS BATTEN 4 FEET 20 w) (Make Havells/Polycab/Crompton) or equivalent to ISI Standarad. |
| 71 | Installation, testing and commissioning of pre-wired, LED FITING of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 72 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 73 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 74 | 6 way, Double door |
| 75 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 76 | Single Pole MCB |
| 77 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 78 | 40 Amps, 2 Pole Isolator |
| 79 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 80 | Providing and laying earth connection from earth electrode with 6.00 mm sq. mm FR Flexible Wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 81 | Providing and fixing 4.00 mm FR Flexible Wire on surface or in recess for loop earthingas required. |
| 82 | Supplying and fixing of new generation energy saving enviroment friendly long life 25 W LED street light made up of pressure dia cast aluminium housing with high power LED as light source and embeded PC cover having top opening seprate driver compertment with IP65 PROTECTION AND ik07 IMPACET RESISTENCE (MAKE : Polycab CAT No.PUBO506109 ) along with its Mountning (GI PIPE 32mm) (Make: Bajaj /Havells /Orient/Crompton or equivalent to ISI standard). |
| 83 | Supplying and fixing of Wooden meter board of Size 10\\" X 12\\" for fixing of Energy meter or equivalent to ISI standarad. Please Enable Macros to View BoQ information |