| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 2 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. |
| 3 | M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 4 | All as per item No. 03 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 5 | All as per item No. 03 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps point on same board complete ditto |
| 6 | All as per item No. 03 mentioned here-in-before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto |
| 7 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings with sunken cast iron /pressed steel terminal box ,flush to surface of 1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 to finishing the match surface complete all as specified and directed by Engr- in-charge.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 8 | All as per item No. 07 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 9 | All as per item No. 07 mentioned here-in-before but for one point controlled by two, two way swiches with cables of 1.5 sqmm size complete all as directed and specified |
| 10 | All as per item No. 07 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto |
| 11 | M & L Sub main wiring with two runs of 2.5 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through including PVC Casing capping of suitable size with all accesories and fittings, fixed to wall/ceiling etc including 2.5 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete all as specified and as directed by Engineer-in-charge. (Note : Two run cables and one run of earth wire and one run of casing capping will be measured as one length.) |
| 12 | M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of casin capping shall be measured as one length) |
| 13 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin capping shall be measured as one length) |
| 14 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVCconduit of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin capping shall be measured as one length) |
| 15 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 16 | S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 17 | S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. |
| 18 | S & F in repair Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 19 | S & F Switch socket combination 2 in 1, 6 Amp, flush type complete all as specified and as directed. |
| 20 | S & F in repairs Switch socket combination 2 in 1, 6 Amp, flush type complete all as specified and as directed |
| 21 | S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. |
| 22 | S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed. |
| 23 | S & F bell push flush type, 6 amp 240 volts, complete all as specified and as directed. |
| 24 | S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed. |
| 25 | S & F Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 26 | S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 27 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 28 | S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 29 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. |
| 30 | S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. |
| 31 | S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 32 | S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 33 | S & F in repairs switch modular, 1 Way, 10 amp, 240 volts,1 Module complete all as specified and as directed. |
| 34 | S & F in repairs switch modular, 1 way, 16 amp 240 volts,1 Module complete all as specified and as directed. |
| 35 | S & F in repairs switch modular, Two way, 10 Amp, 240 volts,1 module complete all as specified and as directed. |
| 36 | S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 37 | S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 38 | S & F in repairs stepped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed. |
| 39 | S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed. |
| 40 | S & F in repair madular Switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed |
| 41 | S & F in repair Rigid non-metalic PVC casing capping of size 25mm inclusive of all fittings and fixing accessories complete all as specified and directed. |
| 42 | S & F in repair Rigid non-metalic PVC conduit (25mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. |
| 43 | S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. |
| 44 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 45 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 46 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed. |
| 47 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specified and directed. |
| 48 | S & F in repair LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specified and directed. |
| 49 | S & F LED tube light fittings, surface mounting, general purpose, in extruded aluminium housing, 20 Watt and 2000 Lumens, 6500K with all accessories, internally prewired and connecting up including tube lamp complete all as specified and directed. |
| 50 | S & F in repair LED tube light fittings, surface mounting, general purpose, in extruded aluminium housing, 20 Watt and 2000 Lumens, 6500K with all accessories, internally prewired and connecting up including tube lamp complete all as specified and directed. |
| 51 | S & F LED tube light fittings, surface mounting, general purpose, in extruded aluminium housing, 10 Watt and 1000 Lumens, 6500K with all accessories, internally prewired and connecting up including tube lamp complete all as specified and directed. |
| 52 | S & F in repair LED tube light fittings, surface mounting, general purpose, in extruded aluminium housing, 10 Watt and 1000 Lumens, 6500K with all accessories, internally prewired and connecting up including tube lamp complete all as specified and directed. |
| 53 | S & F LED lamp, 12 watts, 6500K, 1200 Lumens suitable for lamp holder complete all as specified and as directed. |
| 54 | Supply & fix in repairs energy efficient Invertor LED bulb 12 watts, 230Volts, AC, 50Hz, inbuilt Li-ion rechargeable battery of 03 hours back up during power cut, ensuring uninterrupted illumination by automatically switches to battery mode, provide stable and flickering free bright & cool day light (6500K) or warm white or as directed by Engr-in-Charge ranging between 3000K to 6500K and suitable for holder base type B 22 & E 27 having including taking down old unserviceable bulb of any type, make & keeping in safe custody to issue under schedule of credit complete all as specified and directed. |
| 55 | Supply & fix in repairs energy efficient Invertor LED bulb 9 watts, 230Volts, AC, 50Hz, inbuilt Li-ion rechargeable battery of 03 hours back up during power cut, ensuring uninterrupted illumination by automatically switches to battery mode, provide stable and flickering free bright & cool day light (6500K) or warm white or as directed by Engr-in-Charge ranging between 3000K to 6500K and suitable for holder base type B 22 & E 27 having including taking down old unserviceable bulb of any type, make & keeping in safe custody to issue under schedule of credit complete all as specified and directed. |
| 56 | S & F 12 Watt LED downlight, round and square recess mounted LED edge lit slim downlight with die-cast aluminium housing finished in premium white powder coating, efficacy 100lm/w & 120 lm/w with all accessories and connecting up including lamp complete all as specified and directed. |
| 57 | S & F in repair 12 Watt, LED downlight, round and square recess mounted LED edge lit slim downlight with die-cast aluminium housing finished in premium white powder coating, efficacy 100lm/w & 120 lm/w with all accessories and connecting up including lamp complete all as specified and directed. (Make: Crompton Cat No. LSCRM-12W-CDL or equivelant of make as per list of manufacturer) |
| 58 | S & F 36 Watt (100lm/w), 2ftx2ft, LED recessed full lit luminaire with glare free uniform illumination with loger life and less maintenance with all accessories, internally prewired and connecting up including tube lamp complete all as specified and directed. |
| 59 | S & F in repair 36 Watt (100lm/w), 2ftx2ft, LED recessed full lit luminaire with glare free uniform illumination with loger life and less maintenance with all accessories, internally prewired and connecting up including tube lamp complete all as specified and directed. |
| 60 | S & F 15 Watt LED cylinder Focus light, Colour Temp 3000K to 5700K, warm white colour with all accessories including lamp, internally prewired and connecting up complete all as specified and directed. |
| 61 | S & F in repair 15 Watt LED cylinder Focus light, Colour Temp 3000K to 5700K, warm white colour with all accessories including lamp, internally prewired and connecting up complete all as specified and directed. (Make: Cromptons Cat No. CDS-201-15-57-HL2-NWH or equivelant of make as per list of manufacturer) |
| 62 | S & F in repair 6/7 Watt, LED picture light fittings, having 270 Lumen and 3000K, correlated colour temperture, decorating light with all accessories, internally pre-wired and connecting up complete all as specified and directed. |
| 63 | S & F in repair LED 120 Watt Higbay luminaire, suspended type PDC aluminium housing with PC lens cover and mounting eye bolt with IP65 protection upto 125 lm/W with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. |
| 64 | S & F in repairs LED panel Driver 24 to 36/40 watts as per site requirement complete all as specified and as directed. |
| 65 | Carry out DOOR TO DOOR / MAINT MELA in govt OTM accn (Single living/technical/official area) temporary/permanent nature of bldgs. Month single/multistories upto G+2 floor level bldgs inside Rayang Mil Stn by deputing minimum 1 x electrician and 2 x helper for visiting to bldgs/units where directed, lodging electric complaints from user, making job cards and obtaining signature of MES NCO/JCO/ resident of concerned unit after necessary rectification of lodged complaint. Job also includes visual inspection of electrical connections, checking of defective electrical ckt for continuous electric supply or broken neutral system, rectify the same, tightening of loose wire / circuit by using the same old wire or by using new wire up to 1.00 mtr length, screws, machine screws, insulation tape, small copper lugs of various size / shape etc. as required at site to complete the job. The job also includes replacement of unserviceable accessories, fittings and fixtures of terminal board, luminairs, taking photographs in presence of MES NCO/JCO while workman rectifying the complaints, keeping unserviceable fittings/fixture or other old unsv material in safe custody to issue under schedule of credit, submitting Job Cards & colour photographs in writeable CD to the Engineer-in-Charge duly completed in all respect all as specified and directed for perusal and signature before claiming the payment.NOTE:(i) All bldgs are inside Rayang Mil Stn but in scattered pockets/areas.(ii) Spare parts such as PT switch, ceiling rose, fan capacitor, 5/15Amp SSC, Lamp holder, fan ragulator, LED tube light fig / LED bulb of any type and watts etc will be measured and paid separately under relevant item of BoQ.(iii) IR testing of electrical ckts where necessary will be measured and paid separately under respective item.(iv) For shifting of material from store yard to wk site, only Govt Veh alongwith Dvr MTD will be facilitated by the department. Hence, no extra payment will be made against transportation of workmen deployed for the job.(v) Necessary arrangement of skilled & un-skilled workmen, consumeable items such as insulation tape, cotton waste for cleaning, wire upto 1.00mtr for each complaint, requisite T&P, complaint book (format be obtained from the Engr-in-Charge), banner for MES mela, loud speeker for wide publicity / awareness connecting up, complete all as specified and as directed. |
| 66 | S & F in repair sheet metal enclosure, single door MCB DBs, phosphatised, powder coated, Single pole & neutral (SPN), 02 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed. |
| 67 | S & F in repair Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. |
| 68 | S & F in repair Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. |
| 69 | S & F in repair Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. |
| 70 | S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed |
| 71 | S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed |
| 72 | S & F MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed |
| 73 | S & F in repair MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed |
| 74 | S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed |
| 75 | S & F in repairs MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed |
| 76 | S & F MCB, TPN 40-63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed |
| 77 | S & F in repair MCB, TPN 40-63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed |
| 78 | S & F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cross sectional area 6 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed. |
| 79 | S & F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cross ectional area 10 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed. |
| 80 | S & F 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 16 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed. |
| 81 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one for OJL/ OR/ LIVING / STORE Shelter/ Permt Bldg/ Cook house/ Masses etc complete all as specified and as directed by the Engineer-in-Charge. |
| 82 | M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 83 | M & L for testing of internal wiring insulation resistance, continuity of each circuit (i.e each ougoing MCB) of each MCB distribution board of OTM ACCN (Upto G+2) including earth resistance of connected earth as per the standard IS testing Code and recording results in test sheet to be submitted in triplicate duly signed by the contractor complete all as directed by the Engr-in-Charge(Note: T & P required for testing shall be arranged by the contractor at his own cost) |
| 84 | M & L for testing of building lightening arrestor network by using digital earth tester after disconnecting the aluminium roof conductor and earth GI strip from earth testing terminal block of buildings where directed to check the earth pits as per the standard IS testing Code and recording results in test sheet to be submitted in triplicate duly signed by the contractor complete all as directed by the Engr-in-Charge.(Note: T & P required for testing shall be arranged by the contractor at his own cost) |
| 85 | S&F Air termination aluminium single pointed rod 12 mm dia, 300 mm long incl taking down old unserviceable one complete all as specified and as directed. |
| 86 | Supply and fix in repair test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw complete all as specified and as directed. |
| 87 | Supply & fixing in repair condenser of 1.5 Mfd suitable for PVC exhaust fan and wall mounted fan of any make and size complete all as specified and as directed. |
| 88 | Supply and fix in repair plug top 3 pin 5/6A 240V Easy to carry, Non flammable & Durable Heavy duty , nickel plated brass terminals Long lasting polycarbonate plastic material complete all as specified and directed by Engineer-in-Charge. |
| 89 | S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 1.5 sqmm complete all as specified and as directed. Please Enable Macros to View BoQ information |