| 1 | Scheduel 'A' Part-I (B/R Works)Dismantling of asbestos cement (corrugated, semi corrugated etc) sheeting in roof covering, complete all as specified and directed. |
| 2 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern roof covering, complete all as specified and directed. |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved multi colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 4 | S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of approved multi colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 5 | S&F pre painted coloured galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved multi colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa for roofs, bent to a curve of any radius with specified side lap as per manufacturer instruction, complete all as specified and directed. |
| 6 | Dismantling of timber scantling 40Sqcm and over in section, in any position as in unframed or framed work, complete all as specified and directed. |
| 7 | Dismantling of structural steel work including doors, gates but excluding framed truss etc, complete all as specified and directed. |
| 8 | M&L for roof trusses (framed, purlins or rafters of Fe 410W (grade E-250 quality A)) including distance pieces and cleats, complete all as specified and directed. |
| 9 | M&L for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanised steel sheet of size 24 x 32 x 300mm spaced at 1200mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fittings of 1200mm long screws Tee with (double stiching) to interlocked between main runners at 600mm centre to centre from 1200 x 600mm modules cross tee longer than 600mm modules to be formed by fittings 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanised steel of size 19 x 19mm and 300mm long of white colour all as per insturctions including dismantling of existing board with cover fillets etc, complete all as specified and directed. |
| 10 | Ddemolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 11 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed. |
| 12 | All as per item No 11.00 here-in-before but except stone. Note:-Stone retrieved from item No 10.00 will be re-used. |
| 13 | M&L for brickwork with sub class ‘B’ bricks, straight or curved on plain exceeding 6m mean radius, built in CM 1:6, complete all as speified and directed. |
| 14 | M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plain and any radius in half brick thick wall built in cement mortar 1:4, complete all as specified and directed. |
| 15 | All as per item No 13.00 here-in-before but except brick.Note:- Old brick retrieved from demolition shall be used. |
| 16 | M&L for rendering 20mm thick in cement mortar 1:4 on stone surfaces of walls any type and any height finished even and smooth without using extra cement, complete all as specified and directed. |
| 17 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 18 | M&L for rendering 15mm thick on fair faces of brick, stone or concrete surface including in CM (1:6), finished even and smooth without using extra cement, complete all as specified and directed. |
| 19 | M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion, complete all as specified and directed. |
| 20 | Complete removal of exisitng treatment from old plastered surfaces of walls, preparing surfaces including washing rubbing down and stopping of distempered surface and applying two coats of distemper oil emulsion, complete all as specified and directed. |
| 21 | M&L for rendering 15mm thick in cement mortar 1:4 on concrete/ brick surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 22 | M&L for preparation of new plastered surfaces of walls and applying two coats of exterior weather proof paint of apex ultima of ASIAN or equivalent make (multi colour pattern as approved by GE), over and including a coat of primer, complete all as specified and directed. |
| 23 | Complete removal of existing treatment on old plastered wall/ roof surfaces including cornices and chajjas etc and applying two coats of exterior weather coat paint of apex ultima of asian or equivalent make (multi colour pattern as approved by GE), complete all as specified and directed. |
| 24 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, ends, swan-necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 25 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints in eaves gutters, with all fittings such as elbow, equal Tee, coupling, 'Y' Tee etc, including MS clamp and holding arragment for MS steel , complete all as specified and directed. |
| 26 | M&L for preparation of new or previously undecorated steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 27 | Schedule 'A' Part-II (E/M Works)Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc, removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc to match with existing specifications, complete all as specified and directed. |
| 28 | M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and casing/caping medium grade of 25mm width complete with all acessories including PVC box ISI marked for mounting of switches, sockets, fan regulator and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the disturbed surfaces to match with the existing, compete all as specified and directed. Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase, black for neutral and green for earth. |
| 29 | All as per item No 28.00 here-in-before but for one 3 pin 6 Amp socket outlet on same board controlled by one 5 Amp switch. |
| 30 | All as per item No 28.00 here-in-before but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 Amp switch. |
| 31 | All as per item No 28.00 here-in-before but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper conductor cable with 2.5 sqmm single core multistraind FRLS copper conductor cable as earthling lead. |
| 32 | M&L for switch piano, flush type single pole, one way 6 Amp, 240 volts, complete all as specified and directed. |
| 33 | S&F bell push flush type single pole one way 6 amps 240 volts, complete all as specified and directed. |
| 34 | S&F socket 2 in 1, 3 pin, 6 amp flush type, complete all as specified and directed. |
| 35 | S&F switch socket outlet combination 2 in 1, flush type single pole, one way 5 &15 Amp, 240 volts, complete all as specified and directed. |
| 36 | S&F ceiling fan regulator electronic, flush type to control speed of fan from 0 to 100% rotary type five step 240 volts AC, complete all as specified and directed. |
| 37 | S&F in replacement call bell AC, 230 volts, single pole, ding-dong sound type, complete all as specified and directed. |
| 38 | M&L for point complete with 1.5 Sqmm single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor (FRLS) drawn through in and including PVC casing/ caping (minimum 25mm in width), with the fittings such as tee, corners, overlapping connectors, etc fixed over walls, ceiling, floors etc also including PVC insulated unsheathed, multi stranded copper earth continuity conductor 1.5 Sqmm cable (FRLS) (green), connected to common earth dolly and also providing modular metal flush boxes with modular white cover plate and frame of module suitable for mounting modular switche, socket, fan regulators etc with necessary screws as directed by the GE for one light point/ one fan point / one bell point controlled by one switch, complete all as specified and directed. |
| 39 | All as per item No 38.00 here-in-before but for one 3 pin 5 Amp socket outlet on same board controlled by one 5 Amp switch. |
| 40 | All as per item No 38.00 here-in-before but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 Amp switch. |
| 41 | All as per item No 38.00 here-in-before but for one 3 pin 16 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper conductor cable with 2.5 sqmm single core multistraind FRLS copper conductor cable as earthling lead. |
| 42 | S&F modular type switch 6 Amp, 1 way and 1 module, complete all as specified and directed. |
| 43 | S&F modular type switch 16 Amp, 1 way and 1 module, complete all as specified and directed. |
| 44 | S&F modular type outlet socket 6 Amps, 2/3 pin cobmination, 2 module, complete all as specified and directed. |
| 45 | S&F modular type outlet socket 6/16 Amps, 6 pin cobmination, 2 module, complete all as specified and directed. |
| 46 | S&F modular bell switch 6 Amp, 1 module, complete all as specified and directed. |
| 47 | S&F modular type fan regulator, stepped type, 100 watt 2 module, complete all as specified and directed |
| 48 | S&F ceiling rose 3 phase/ PVC/ polycarbonate isolated body surface bakelite 63.5 x 17mm terminals, complete all as specified and directed. |
| 49 | S&F lamp holder insulated body PVC/ polycabonate type with back plate suitable for batten/ angular/ pendent fittings including LED lamp 9/10 watt, complete all as specified and directed. |
| 50 | S&F in replacement for retrofit inverter based LED bulb 9 watts, 240 volts, 50Hz suitable for housing in pendent/ batten/ angular holder, complete all as specified and directed. |
| 51 | S&F in replacement inverter based LED Tube light fitting in replacement complete with 1x 20 watts, 220V, PVC batten with connection complete prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed copper conductor cable and necessary fixing arrangement at any height, complete all as specified and directed. |
| 52 | S&F in replacement LED Tube light fitting in replacement complete with 1x 20 watts, 220V, PVC batton complete prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed copper conductor cable and necessary fixing arrangement at any height, complete all as specified and directed. |
| 53 | S&F in replacement decorative wall light suitable for 9 W LED lamp B22 base co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete prewired and connecting electrically, complete all as specified and directed. |
| 54 | S&F in replacement high efficacy 2 x 2 feet recess mounting LED flat panel light fittings 40W LED 3000K - 6000K edge lit luminaire as required on site and complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed.Note:- Material required such as for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost. |
| 55 | S&F in replacement for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 9 to 18 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using PVC insulated over all sheathed with flexible copper conductor, complete all as specified and directed. |
| 56 | S&F in replacement for LED Tube light fitting, complete with 9/10 watt, 2 feet, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm and necessary fixing arrangement at any height, complete all as specified and directed. |
| 57 | S&F in replacement LED bldg street light fitting 30 Watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket etc including connection, complete all as specified and directed. |
| 58 | M&L in replacement for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, earth plate surrounded by and packed with 15cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-1 & RCC cover all as specified & shown in elect plate No 3 of SSR part I of 2009 including testing on completion complete after, dismantling of old unserviceable earthing with all material etc, complete all as specified and directed.Note :- Earth strip and protection pipe upto board is included in the rate quoted. |
| 59 | M&L for sub main wiring complete with 2 run of 10sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners, overlaping connector etc of suitable size fixed on surface of walls/ roofs/ ceiling and including 01 run of 10sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. Note :- 02 run of 10sqmm single core copper conductor cable and 01 run of 10 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase, black for neutral and green for earth. |
| 60 | M&L for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners, overlaping connector etc of suitable size fixed on surface of walls/ roof/ ceiling and including 01 run of 6 Sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. Note :- 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase, black for neutral and green for earthing. |
| 61 | M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/ roofs/ ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed.Note :- 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase, black for neutral and green for earthing. |
| 62 | S&F MCB distribution board TPN 4 way, double door 415 volts duly painted with epoxy based powder coated painting suitable for mounting MCB TP/FP as incomer of rating upto 63 Amps, and MCB SP/TP as outgoings complete including removing old unserviceable DB and making good disturbed surfaces, complete all as specified and directed. Note :- MCBs will be measured separately. |
| 63 | S&F factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distribution board 12 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 100 Amps, FP, and MCB SP/TP as outoing and complete including taking down old unserviceable DB's and making good the disturbed surfaces, complete all as specified and directed.Note:- MCCB's & MCBs will be measured & paid separately. |
| 64 | M&L sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-42 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete including removing of old unserviceable DB, complete all as specified and directed. Note :- New MCBs will be measured separately. |
| 65 | M&L in replacement for sheet metal enclosure VTPN distribution board, double door single pole and neutral with IP-66 protection single phase 415 volts 08 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing MCCB and incommer capacity 100 Amps and SPN as outgoing and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 66 | M&L in replacement for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-42 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair, complete all as specified and directed.Note :- MCCB's & MCBs will be measured & paid. |
| 67 | M&L in replacement MCB TP 25 to 63 Amp, 415V 10KA 'C' curve of current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed. |
| 68 | M&L in replacement for MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed. |
| 69 | M&L in replacement for MCB single pole & neutral 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed. |
| 70 | M&L in replacement for MCCB FP 415 volts any rating from 63 Amp with ruptring capacity 16 KA, including providing thimble for out going cables, complete all as specified and directed. |
| 71 | S&F in replacement factory made, triple pole and neutral enslosure with and including 2 pin and earth plug and socket complete, also with and including one triple pole, MCB 32 Amps, 10KA, 415 volt, complete all as specified and directed. |
| 72 | Supply, laying, connecting and testing service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories, complete all as specified and directed. |
| 73 | Supply, laying, connecting and testing of service cable of size 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories, complete all as specified and directed. |
| 74 | S&F in replacement LED driver suitable for LED light fitting from 24W to 40W including removing and refixing the fitting after servicing and connecting electricaly using cord PVC insulated over all sheathed flexible copper conductor cable sqmm, complete all as specified and directed. |
| 75 | Supply only PVC tape 20mm in width & 5m in length, complete all as specified and directed. Please Enable Macros to View BoQ information |