| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or salimar pattern roof coverings complete all as specified and directed by Engr-in-charge. |
| 2 | Supply & Installation Pre-painted, High Tensile 550 Mpa yield strength, Bare Galvalume Steel Sheet having maximum pitch of 250mm c/c & minimum 30mm crest depth in length as per site requirement. The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150. The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap. The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal Complete all as per manufacturers specifications and and directed by Engr-in-charge.Note:- The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations) |
| 3 | Supply & Installation Pre-painted, High Tensile 550 Mpa yield strength, Bare Galvalume plain Steel Sheet as in roof covering, eaves board, ridges, fascia etc. The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150. The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap. The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal Complete all as per manufacturers specifications and and directed by Engr-in-charge.(Note:- The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations.) |
| 4 | Labour only for re-fixing of old dismantled pre-painted, High Tensile 550 Mpa yield strength, Bare Galvalume plain Steel Sheet as in roof covering, eaves board, ridges, fascia etc. The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150. The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap. The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal Complete all as per manufacturers specifications and and directed by Engr-in-charge.(Note:- The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations.) |
| 5 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engr-in-charge. |
| 6 | Erection, fabrication and fixing only of old dismantled roof trusses (framed), trussed purlins, crane gantries, rails, fastenings, and heavy bracket framing (beam, tee, angle, channel or flat sections), including distance pieces, cleats, etc., after necessary rectification and straightening to make them serviceable, complete all as specified and directed. (Note: The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations.) |
| 7 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410-W (Gde 250 quality A) complete all as specified and directed by Engr-in Charge.(Note: The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations.) |
| 8 | S&F of channel, angle, flat iron or Tee sections, bent to required shape, holes drilled as in cross bracings etc fixed independently with connecting plates including, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed. (Note: The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations.) |
| 9 | M&L for MS flat iron bend to shape holes driled etc complete as in hold fast and wind ties for roof etc including securing bolts conforming to Fe-290 Gde E-165 including one coat or red oxide paint complete all as specified and directed. (Note: The rate is inclusive of all necessary scaffolding, staging, access arrangements, and all other incidental works required for execution at any height. The work shall be carried out at multiple building locations.) |
| 10 | Dismantling timber scantling 40 sqcm and over in section, in any postion complete all as specified and directed. |
| 11 | M&L second class hardwood timber scantling of any size in any position such as truss, purlin etc complete all as specified and directed |
| 12 | M&L for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 13 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats synthetic enamal paint over one coat of red oxide primer complete all as specified and directed. |
| 14 | M&L for preparation of new steel surfaces n exc 10cm width or girth and applying one coats of synthetic enamel complete all as specified and as directed. |
| 15 | Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including removing rubbish off the premises complete all as directed |
| 16 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thick, including removing rubbish off the premises complete all as directed |
| 17 | M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 18 | M&L for reinforced cement concrete M-25 (design mix) as in columns, pillars etc complete all as specified and directed. |
| 19 | M&L for reinforced cement concrete M-25 (design mix) as in beams complete all as specified and directed. |
| 20 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 21 | M&L for Providing, cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate in coping, coving, roof padding etc complete all as specified and directed by Engr-in-charge. |
| 22 | M&L for mild steel TMT bars as in reinforcement 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (wire) annealed not less than 0.9mm dia complete all as specified and directed. |
| 23 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (wire) annealed not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified and directed. |
| 24 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed. |
| 25 | M&L for form work to sides of columns square / rectangular for rough finished surfaces of concrete complete all as specified and directed. |
| 26 | M&L for form work to side and soffits of beams etc for rough finished surfaces complete all as specified and directed. |
| 27 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-charge. |
| 28 | M&L brick work with sub class `B' bricks straight or curved on plan exc 6.0m mean radius built in cement mortor 1:6 complete all as specified and directed by Engr-in-charge. |
| 29 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 30 | M & L for Rendering 5mm thick in cement mortar in 1:3 on ceiling etc. complete all as specified. |
| 31 | M & L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces etc. complete all as specified. |
| 32 | M & L for Rendering 15mm thick in cement mortar in 1:4 on other than fair faces of brick work or concrete surfaces etc. complete all as specified. |
| 33 | M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Oil bound distemper over a coat of chalk whiting priming paint over 1mm thick wall care putty in two coats complete all as specified. |
| 34 | M&L for applying two coat of oil bound distemper over two coat of wall care putty incl complete removal of existing treatment complete all as specified and directed by Engr-in-charge. |
| 35 | M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. over and including a coat of alkali resistant primer complete all as specified and directed. |
| 36 | M&L for preparing old surfaces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. over and including a coat of alkali resistant primer complete all as specified and directed. |
| 37 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 38 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid 605x605mm complete all as specified and directed by Engr-in-charge. |
| 39 | S&F Hangers 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified |
| 40 | M&L 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/Gt/Aluminium framework with screws complete all as specified and directed by Engr-in-charge. |
| 41 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drwaing |
| 42 | S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 43 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed by Engr-in-charge. |
| 44 | M&L cement concrete type D2 (1:4:8) 40mm graded stone aggregate as in foundation and mass concrete complete all as specified. |
| 45 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge. |
| 46 | Demolition of stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar etc complete all as specified. |
| 47 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 etc complete all as specified and directed by Engr-in-charge. |
| 48 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 etc complete all as specified and directed by Engr-in-charge. |
| 49 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 etc complete all as specified and directed by Engr-in-charge. |
| 50 | S&F glazed ceramic coloured tiles 7 to 8mm thick 450 x 350mm size in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 etc complete all as specified and directed by Engr-in-charge. |
| 51 | M & L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like over 20 mm thick cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and 100 mm stainless steel rawl plug of Hilti will be fixed @ 2 Nos per Sqm complete all as specified and directed by Engr-in-charge. |
| 52 | Hacking out old broken glass from metal frame including punching or drilling out old glazing pins/springs clips and providing and fixing new ones complete all as specified. |
| 53 | S&F 3mm thick sheet glass ordinary quality in squares n.exc 0.50sqm each pane complete all as specified. |
| 54 | S&F 3mm thick figured glass, pin head type in square n.exc 0.50 sqm in each pane complete all as specified. |
| 55 | S&F in repair 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc. complete all as specified. |
| 56 | S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc. complete all as specified. |
| 57 | S&F in repair110 mm bore PVC (SWR) bend any radius with access door etc. complete all as specified. |
| 58 | S&F in repair 75 mm bore PVC (SWR) bend any radius with access door etc. complete all as specified. |
| 59 | S&F in repair 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door etc. complete all as specified and directed. |
| 60 | S&F in repair 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door etc. complete all as specified and directed. |
| 61 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store etc. complete all as specified. |
| 62 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store etc. complete all as specified. |
| 63 | S&F of 15 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed. |
| 64 | S&F of 20 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed. |
| 65 | Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed. |
| 66 | Dismantling and taking down unserviceable main switches, DBs etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed. |
| 67 | M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked concealed in wall/fixed to roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular back plate and top cover for mounting switch, sockets etc including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps. complete all as specified & as directed. |
| 68 | Description all as per item No 67.00 here in before but for one 79 point 5/6 Amps switch socket outlet point controlled by one switch on the same board. |
| 69 | Description all as per item No 67.00 here in before but for one 79 pin 5/6 Amps switch socket outlet point controlled by one switch on independent boad. |
| 70 | Description all as per item No 67.00 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15/16 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 71 | M & L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including PVC Casing and Caping (medium grade) with all fittings and accessories ISI marked fixing in wall/roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular surface boxes of appropriate size & thickness fixed to wall with modular back plate and top cover for mounting switch, sockets etc making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps. complete all as specified & as directed. |
| 72 | All as per item No 71 here-in-before but One 3 pin socket outlet 5/6 Amps on the same board with other switchs with cables 1.5 Sqmm size. |
| 73 | All as per item No 71 here – in – before but for one 3 / 5 -pin switch socket outlet 5/6 amps on independent board. |
| 74 | All as per item No 71 here – in – before but for one switch socket outlet 15/16 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable. all as specified and as directed. |
| 75 | Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked all as specified and as directed. |
| 76 | Supply and fix Modular switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked all as specified and as directed. |
| 77 | Supply and fix Modular Bell push 6A 1 module 230 Volts,50Hz, ISI marked all as specified and as directed. |
| 78 | Supply and fix Bell, Ding Dong electric AC 230 Volts single pole complete all as specified and as directed. |
| 79 | Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked all as specified and as directed. |
| 80 | Supply and fix Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked all as specified and as directed. |
| 81 | Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed. |
| 82 | Supply and fixing Modular angle holder insulated body with back plate for batten fitting all as specified and as directed. |
| 83 | Supply and fixing 9W/10W LED retro fit B-22 holder base with poly carbonate body and aluminium heat shrink Invertor lamp, complete all as specified and directed. |
| 84 | Supply and fixing LED batten surface / wall mounted with specially designed comprises of extruded channel in thermally conductive material. High transulucent serrated milky white diffuser used to grt glare free and smooth light distribution. power consumption 20W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per IEC standard all as per specified and directed. |
| 85 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserviceable fitting complete all as specified and as directed. |
| 86 | Supply and fixing Decorative, wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base complete all as specified and directed. |
| 87 | Supply and fixing in repairs LED 2X2 PANEL 36 W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling complete all as specified and directed. |
| 88 | Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete |
| 89 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 90 | S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting complete all as specified and as directed. |
| 91 | S&F TPN DB with suitable for TPN MCB incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, concealed in wall complete all as specified and as directed. |
| 92 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 4 way 240 Volts AC, concealed in wall complete all as specified and as directed. |
| 93 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall complete all as specified and as directed. |
| 94 | Supply and fixing 415V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN 25 To 63 Amps. capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 95 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 6 to 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 96 | Supply and fixing in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 32 AMP capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 97 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 98 | Taking down carefully sub main wiring of any size/core/type including conduit/ cashing/ batten of any type and making good disturbed surfaces to match with the existing surface roof/ wall/ floor, complete all as specified and directed. |
| 99 | M&L for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof including taking down of old unservicible sub main wiring complete all as specified and directed.(Note three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length) complete all as specified and directed by Engr-in-charge. |
| 100 | M&L for sub main wiring along with earth wire of size two run of 2.5 sq mm + one run of 2.5 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof including taking down of old unservicible sub main wiring complete all as specified and directed. (Note: Three run of 2.5 Sq mm copper wire including one run of 25 mm of size PVC condute shall be measured as one unit length) complete all as specified and directed by Engr-in-charge. |
| 101 | M&L for sub main wiring along with earth wire of size two run of 4 sq mm + one run of 4 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof including taking down of old unservicible sub main wiring complete all as specified and directed. (Note: Three run of 4 Sq mm copper wire including one run of 25 mm of size PVC condute shall be measured as one unit length) complete all as specified and directed by Engr-in-charge. |
| 102 | Taking down Existing unserviceable exhaust fan with any size with, blades, and louvers and keep in safe custody and deposited to Age E/M store complete all as specified and directed. |
| 103 | Supply and Fixing exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed. |
| 104 | Supply and Fixing exhaust fan, PVC body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed. |
| 105 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed. |
| 106 | M & L for Dismantling unserviceable/old ACSR conductors of any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed. |
| 107 | M & L for Dismantling unserviceable cross arms, clamps etc complete all as specified and directed.. |
| 108 | M & L for Dismantling insulator any type, any size from HT/LT poles complete all as specified and directed. |
| 109 | Dismantling unserviceable concrete/ Steel poles/ struts, any sizes including demolition of foundation concrete & removing from site complete all as specified and directed. |
| 110 | Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 111 | Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick for any type of soil all as specified and directed by Engr-in-Charge |
| 112 | Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point all as specified and directed by Engr-in-Charge |
| 113 | Supply and spread clean dry river sand in cable trenches as in cable cushioning all as specified and as directed by engr-in-charge |
| 114 | Supply and laying un-reinforced precast concrete cable cover class HV type-1 of flat size 300mmx180mmx40 mm complete in trenches all as specified and directed. |
| 115 | M&L precast concrete cable cover, class LV, type 1 with peak, size250mm x 150mm x 40mm complete all as specified and directed by Engr-in-charge. |
| 116 | M & L for laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area of size 95 Sq mm 3 core all as specified and directed by Engr-in-Charge. |
| 117 | M&L for taking out old UG cable of any size/ type from trenches etc. for re-laying works and for connection complete all as specified and directed by Engr-in-ChargeNote :- 1. Excavation and earth work should be measured and paid separately. |
| 118 | M&L for relaying old serviceable UG cable of any size/ type on trenches/ wall/ roof etc. after necessary repair/ rerouting works complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 119 | M&L for relaying old serviceable UG cable of any size/ type on trenches/ wall/ roof etc. after necessary repair/ rerouting works complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |