| 1 | Demolition of cement concrete of any description and in any position not otherwise pecifically provided for, complete all as specified and directed. |
| 2 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 3 | Taking down cement or cement plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 4 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern roof coverings, complete all as specified and directed. |
| 5 | Dismantling of asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings, complete all as specified and directed. |
| 6 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 7 | Dismantling of stone slabs in roofs, suspended floors, chajjas, landings, etc any thickness, jointed in any mortar, complete all as specified and directed. |
| 8 | Dismantling of water tank of capacity 500 to 1000 ltr, complete all as specified and directed. |
| 9 | S&F rotational moulded polyethlene water storage tank 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed. |
| 10 | M&L for disconnecting existing tanks exceeding 250 and not exceeding 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc measured separately), complete all as specified and directed. |
| 11 | Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area outside MoD land as own arrangement by contractor and providing following :- (a) Rendering 10mm thick in cement mortar 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement.(b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried.(c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. APP membrane shall be laid by auth applicator only(e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat. Note:- (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. |
| 12 | Supply only liquid water proofing compound conforming to IS, complete all as specified and directed. |
| 13 | M&L for cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof padding, roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed. |
| 14 | Taking down/ dismantling of existing roof treatment of any description such as old APP membrane roof treatment etc terracing including screed bed etc. Hessian base felt/ tar felt etc (any type and thickness) and remove the same from site, complete all as specified and directed. |
| 15 | M&L for 10mm thick rendering on fair faces of stone /concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement with water proofing, complete all as specified and directed. Note:- Water proofing compound shall be measured separately. |
| 16 | M&L for roof surface treated with PU elastoseal primer to seal the pores and enhance the adhesive of the coating, supply and applying single component water proofing liquid membrane based on pure, elastomatric, polythiner resin cold applied of spray/ brush applied membrane with an elongation of 650 + 50% and tensile strength not less than 2 Mpa crack bridging ability not less than 2mm. No leakage upto 5 bars of water pressure shore hardness 50 Shore. The minimum thickness to be applied shall be 1.5mm (overall) in two layers (each layer 750 micron) or as per manufacture instructions so as to achieve thickness not less than 1.5mm including providing & laying of protective Geotextile fabric 150 GSM over than entire membrane with proper overlaps of 75mm, complete all as specified and directed Note : (i) The treatment shall be carried out by authorised applicator approved by GE. (ii) Payment will be made after providing warranty certificate from the company.(iii) Roof treatment colour shall be in black/grey. |
| 17 | S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L or J hook and washer in roof, wall etc, complete all as specified and directed. |
| 18 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of multi colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws, complete all as specified and directed. |
| 19 | S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of multi colour (multi colour pattern as approved by GE) having tensile strength of 550 MPA as in ridges fixed with self tapping screws, complete all as specified and directed |
| 20 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of multi colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa as in roof covering bent to curve fixed with self tapping screws, complete all as specified and directed. |
| 21 | S&F rolled mild steel (Fe-290, Gde E-165) for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed. |
| 22 | S&F mid steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to S&F mild steel work as steps including embeding in concrete and screwing etc wind ties for roof including securing bolts, Fe-290 Gde E-165, complete all as specified and directed. |
| 23 | S&F mild steel screw bolts 10 to 16mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and directed. |
| 24 | S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanised steel sheet of size 24 x 32 x 300mm spaced at 1200mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fittings of 1200mm long screws Tee with (double stiching) to interlocked between main runners at 600mm centre to centre from 1200 x 600mm modules cross tee longer than 600mm modules to be formed by fittings 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanised steel of size 19 x 19mm and 300mm long of white colour all as per instructions, complete all as specified and directed. |
| 25 | M&L for rendering 10mm thick on fair faces of brick/stone work or concrete surface in CM (1:6) as in wall, finished even and smooth without using extra cement, complete all as specified and directed. |
| 26 | M&L for rendering 15mm thick on fair faces of brick/ stone work or concrete surface in CM (1:4) as in wall with WPC, finished even and smooth without using extra cement, complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered surface of wall with acrylic smooth exterior paint of required shade in two or more colour pattern in new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed. |
| 28 | M&L for preparation old surface of wall with acrylic smooth exterior paint of required two or more shade for new work (two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed. |
| 29 | M&L for preparation of new plastered surface of wall surfaces including cornices applying two coats of distemper oil emulsion paint over a coat of primer including 2mm thick wall care putty, complete all as specified and directed. |
| 30 | M&L for preparation of old of wall surfaces including cornices applying one coat of distemper oil emulsion paint, complete all as specified and directed. |
| 31 | S&F in repair PVC SWR pipes 110mm bore single socketed in any length with rubber ring joint fixed to or laid in trenches or in floors, walls with steel clamps, complete all as specified and directed. |
| 32 | S&F in repair 110mm bore PVC (SWR) bend with access door any radius, complete all as specified and directed. |
| 33 | S&F of mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290 Gde-E-165, complete all as specified and directed. |
| 34 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 35 | M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 36 | Demolition of brick/ stone work built in cement morter of any descrption including all necessary quions arches piilars etc, complete all as specified and directed. |
| 37 | M&L for brick work in cement mortar (1:6) using old size sub class 'B' bricks in walling, straight or curved on plan exceeding 6m mean radius, complete all as specified and directed. |
| 38 | Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc to match with existing specifications, complete all as specified and directed. |
| 39 | M&L for point wiring for one light point/ fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and casing/ caping medium grade of 25mm width complete with all acessories including PVC box ISI marked for mounting of switches, sockets, fan regulator and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, graded multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces to match with the existing, compete all as specified and directed. Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase black for neutral and green for earthing. |
| 40 | All as per item No 39.00 here-in-before but for one 3 pin 6 Amp socket outlet on same board controlled by one 6 Amp switch. |
| 41 | All as per item No 39.00 here-in-beore but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 Amp switch. |
| 42 | All as per item No 39.00 here-in-before but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper conductor cable with 2.5 sqmm single core multi straind FRLS copper conductor cable as earthling lead. |
| 43 | M&L for switch piano, flush type single pole, one way 6 Amps, 240 volts, complete all as specified and directed. |
| 44 | S&F bell push flush type single pole one way 6 Amps 240 volts, complete all as specified and directed. |
| 45 | S&F socket 2 in 1, 3 pin, 6 Amps flush type, complete all as specified and directed. |
| 46 | S&F switch socket outlet combination 2 in 1, flush type single pole, one way 5 & 15 Amp, 240 volts, complete all as specified and directed. |
| 47 | S&F ceiling fan regulator electronic, flush type to control speed of fan from 0 to 100% rotary type five step 240 volts AC, complete all as specified and directed. |
| 48 | S&F in replacement call bell AC, 230 volts, single pole, ding-dong sound type, complete all as specified and directed. |
| 49 | M&L for point complete with 1.5 Sqmm single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor (FRLS) drawn through in and including PVC casing caping (minimum 25mm in width), with the fittings such as tee, corners, overlapping connectors etc fixed over walls, ceiling, floors etc also including PVC insulated unsheathed, multi stranded copper earth continuity conductor 1.5 Sqmm cable (FRLS) (green), connected to common earth dolly and also providing modular metal flush boxes with modular white cover plate and frame of module suitable for mounting modular switche, socket, fan regulators etc with necessary screws as directed by the GE for one light point/ one fan point / one bell point controlled by one switch, complete all as specified and directed. |
| 50 | All as per item No 49.00 here-in-before but for one 3 pin 5 Amp socket outlet on same board controlled by one 5 Amp switch. |
| 51 | All as per item No 49.00 here-in-before but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 Amp switch. |
| 52 | All as per item No 49.00 here-in-before but for one 3 pin 16 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper conductor cable with 2.5 sqmm single core multistraind FRLS copper conductor cable as earthing lead. |
| 53 | S&F modular type switch 6 Amp, 1 way and 1 module, complete all as specified and directed. |
| 54 | S&F modular type switch 16 Amp, 1 way and 1 module, complete all as specified and directed. |
| 55 | S&F modular type outlet socket 6 Amps, 2/3 pin cobmination, 2 module, complete all as specified and directed. |
| 56 | S&F modular type outlet socket 6/16 Amps, 6 pin cobmination, 2 module, complete all as specified and directed. |
| 57 | S&F modular bell switch 6 Amp, 1 module, complete all as specified and directed. |
| 58 | S&F modular type fan regulator, stepped type, 100 watt 2 module, complete all as specified and directed. |
| 59 | S&F ceiling rose 3 phase/ PVC/ polycarbonate isolated body surface bakelite 63.5 x 17mm terminals, complete all as specified and directed. |
| 60 | S&F lamp holder insulated body PVC/ polycabonate type with back plate suitable for batten/ angular/ pendant fittings including LED lamp 9/10 watt, complete all as specified and directed. |
| 61 | S&F in replacement for retrofit inverter based LED bulb 9 watts, 240 volts, 50Hz suitable for housing in pendant/ batten/ angular holder, complete all specified and directed. |
| 62 | S&F in repair inverter based LED Tube light fitting in replacement complete with 1x 20 watts, 220V, PVC batten with connection complete prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed copper conductor cable and necessary fixing arrangement at any height, complete all as specified and directed. |
| 63 | S&F in repair LED tube light fitting in replacement complete with 1x 20 watts, 220V, PVC batton complete prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed copper conductor cable and necessary fixing arrangement at any height,, complete all as specified and directed. |
| 64 | S&F in replacement decorative wall light suitable for 9 W LED lamp B22 base co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete prewired and connecting electrically, complete all as specified and directed. |
| 65 | S&F in replacement high efficacy 2 x 2 feet recess mounting LED flat panel light fittings 40W LED 3000K - 6000K edge lit luminaire as required on site and complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed.Note:- Material required such as for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost. |
| 66 | S&F in repair for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 9 to 18 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using PVC insulated over all sheathed with flexible copper conductor, complete all as specified and directed. |
| 67 | S&F in repair for LED Tube light fitting, complete with 9/10 watt, 2 feet, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm and necessary fixing arrangement at any height, complete all as specified and directed. |
| 68 | S&F in replacement of LED bldg street light fitting 30 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket etc including connection, complete all as specified and directed. |
| 69 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, earth plate surrounded by and packed with 15 cm thick layer of charcoal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-1 & RCC cover all as specified & shown in elect plate No 3 of SSR part-I of 2009 including testing on completion complete after, dismantling of old unserviceable earthing with all material etc, complete all as specified and directed.Note:- Earth strip and protection pipe upto board is included in the rate quoted. |
| 70 | M&L for sub main wiring complete with 2 run of 10 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners, overlaping connector etc of suitable size fixed on surface of walls/ roofs/ ceiling and including 01 run of 10 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. Note : - 02 run of 10 sqmm single core copper conductor cable and 01 run of 10 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase, black for neutral and green for earthing. |
| 71 | M&L for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners, overlaping connector etc of suitable size fixed on surface of walls/ roofs/ ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/ yellow/ blue for phase, black for neutral and green for earthing. |
| 72 | M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed.Note : - 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earthing. |
| 73 | S&F MCB distribution board TPN 4 way, double door 415 volts duly painted with epoxy based powder coated painting suitable for mounting MCB TP/FP as incomer of rating upto 63 Amps, and MCB SP/TP as outgoings complete including removing old unserviceable DB and making good disturbed surfaces, complete as specified and directed. Note:- MCBs will be measured separately. |
| 74 | S&F factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distribution board 12 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 100 Amps, FP, and MCB SP/TP as outoing and complete including taking down old unserviceable DB's and making good the disturbed surfaces, complete all as specified and directed.Note:- MCCB's & MCBs will be measured & paid separately. |
| 75 | M&L sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-42 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete including removing old unserviceable DB, complete all as specified and directed. Note:- New MCBs will be measured separately. |
| 76 | M&L in replacement for sheet metal enclosure VTPN distribution board, double door single pole and neutral with IP-66 protection single phase 415 volts 08 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing MCCB and incommer capacity 100 Amps and SPN as outgoing and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 77 | M&L in replacement for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-42 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair, complete all as specified and directed. Note:- MCCB's & MCBs will be measured & paid. |
| 78 | M&L in replacement MCB TP 25 to 63 Amp, 415V 10KA 'C' curve of curent carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed. |
| 79 | M&L in replacement for MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed. |
| 80 | M&L in replacement for MCB single pole & neutral 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed. |
| 81 | M&L in replacement for MCCB FP 415 volts any rating from 63 Amp with ruptring capacity 16 KA, including providing thimble for out going cables, complete all as specified and directed. |
| 82 | S&F in replacement factory made, triple pole and neutral enslosure with and including 2 pin and earth plug and socket complete, also with and including one triple pole, MCB 32 Amps, 10KA, 415 volt, complete all as specified and directed. |
| 83 | Supply, laying, connecting and testing in replacement of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories, complete all as specified and directed. |
| 84 | Supply, laying, connecting and testing in replacement of service cable of size 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories, complete all as specified and directed. |
| 85 | S&F in replacement LED driver suitable for LED light fitting from 24W to 40 W including removing and refixing the fitting after servicing and connecting electricaly using cord PVC insulated over all sheathed flexible copper conductor cable sqmm, complete all as specified and directed. |
| 86 | Supply only PVC tape 20mm in width & 5 mtr in length, complete all as specified and directed. Please Enable Macros to View BoQ information |