| 1 | Excavation in foundations, trenches etc in earth work, lift upto 1.50 mtrs.stacking the excavated soil not more than 3 mtrs clear from the edge of excavation and then returning the stacked soil in 15cm layers when required in to plinths, sides of foundations etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within a lead of 20 mtrs in pick and jumper work 50% each. |
| 2 | Providing and laying cement concrete 1:6:12(1cement:6sand: 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth. |
| 3 | 1st class Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:6(1 cement:6sand). |
| 4 | Frist class brick work using common burnt clay building bricks in supper structure in all heights and depth in cement mortar 1:6 (1cement:6sand) |
| 5 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x 5 mm so as to give a fair finish including centring. shuttering. strutting and propping etc with wooden battens and ballies. height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu-reinforced concrete and plain concrete work in Flat surfaces such as soffits of suspended floors, roofs, landings and the like floor etc.upto 200mm in thickness including carriage of materials within all leads and lifts complete in all respect. |
| 6 | Providing and laying cement concrete work 1:2:4(1cement:2sand: 4 water borne aggregate 20mm nominal size & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in suspended floors, roofs, landing shelve and their supports balconies beams, girders bressumers and centilevers upto floor two level. |
| 7 | Providing tor steel reinforcement for RCC work including bending, binding and placing in positon complete upto floor two level. |
| 8 | 15mm cement plaster in single coat in rough side of brick/stone masonery for interior plastering upto floor two level including arrises, internal, founded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding in girth & finished even and smooth in cement mortar 1:5(1cement:5sand). |
| 9 | P/F pressed steel door frames manufactured from commercial MS sheets of 1.25mm thickness including hinges, jump lock jamp. Bead and if required angle threshold of MS angle 50 x 25 mm or base tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamp i/c steel butt hinges 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of steel primer after pretreatment or surface as directed by Engineer-in-charge. |
| 10 | Profile--\\"A\\" |
| 11 | Profile--\\"B\\" |
| 12 | Providing and fixing 1mm thick M.S.sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of red lead paint using flat 30mm x6mm for diagonal braces and control cross/pieces. |
| 13 | Filling in plinth with sand under floors including watering ramming consolidating and dressing complete. |
| 14 | Cement concrete flooring 1:2:4 (! cement:2 sand:4 water borne aggregate 20mm nominal size laid in one layer finished with a floating of neat cement 40mm thick. |
| 15 | P/F on wall face PVC rain water pipe i/c fitting and complete in all respect. |
| 16 | White washing with lime on undecorated wall surface(two coat) to give an even shade i/c throughly brooming the surface to remove all dirt, dust, mortar dirt and other foreign matter. |
| 17 | Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6water borne stone aggregate 20mm nominal size)including finishing the surface of concrete smooth. |
| 18 | Painting two coats (excluding priming coat)on new steel work based surfaces, with ready mixed paint, brushing to give an even shade including cleaning of all dirt, dust and other foreign matter,sand papering and stopping, with paint other than white. |
| 19 | Providing and fixing aluminium tower bolts(berral type)anodized transparent or dyed to required shade and colour with screws etc. complete (250) x 16) |
| 20 | P/F MS grills of required pattern in wooden frames/pressed steel frame with M.S.flat square/round bars 12mm dia with round headed bolts and nuts or by screws Plain grill. |
| 21 | P/F PVC water storage tank of ISI 12701 marked, Gl inlet and out let connection 15 mm nominal bore ball valve and mosquito proof pvc cover with locking arrangment including hoisting upto all heights above ground level of 500 litre capacity. |
| 22 | P/F vitreous china wash down water closet squatting pan (Indian Type WC pan) size 580 mm (Earth work, bed concrete, foot rest and tap should be measured and paid for seprately (Orissa Pattern). |
| 23 | P/F PTMT coloured/ white high polyethylene/ poly propylene 10 litre capacity (full) flush) european standard control low level flushing cistern with fitting with a pair of brackets with fitting such as lead valve, syphon, 15 mm nominal size PVC ball valve with polythene float, with push button, coupling for connections with inlet, outlet and overflow pipe, 40 mm dia CP flush bend i/c cutting holes in walls and making good the same and connecting the flush bend with cistern and closet (over flow pipe to be measured and paid for sepretely). |
| 24 | P/F high pressure PVC spigot and soaket, waste and ventilating pipes ISI marked i/c fixing with approved adhesive etc. complete 110 mm dia. |
| 25 | P/F PVC \\"P\\" or \\"S\\" trap for water closet (squatting pan) ISI marked i/c jointing the trap with the pan and PVC pipe with approved adhesive etc. complete. 110 mm dia |
| 26 | P/F brass bib tap (Superior or heavy type) of 15 mm dia |
| 27 | P/F to wall ceiling and floor galanised mild steel tubes of (light grade) tube fittings and clamps i/c making good the wall ceiling and floor. 15 mm dia |
| 28 | Demolition above ground level upto floor two level including disposal of unserviceable material within 20 metres lead and including cutting the necessary reinforcement and separating from RCC/R.B. work. |
| 29 | Providing electrification facility to all. Pump houses with in all lead and lift complete in all respect. |
| 30 | Wiring for light/Fan point/ Extase fan ]point/call bell point with 1.5 Sqmm PVC insulated heat resitant flame retardent (HRFR)of low smoke singe core (flexible) copper conductor cable PVC casing and capping and earthing the light point with 1.5 mm HRFRLS/ PVC insulated single Group \\"C\\" as required, required including carriage of all material within all leads and liffis. |
| 31 | Wiring for light/power plug with 2x4 Sq.mm PVC insulated heat resistant flame retardent (HRFR) and low smoke single core (flexible) copper conductor cable in PVC Casing & capping along with 1 No., 4sq.mm HRFRLS/PVC insulated single core copper as required including carriage of materials within all leads and lifts. |
| 32 | Wiring for light/power plug with 4x4 sq mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible) copper conductor cable in PVC Casing & capping along with 2 nos.,4sq mm HRFRLS/PVC insulated single core copper as required including carriage of materials within all leads and lifts. |
| 33 | Wiring for light/power plug with 2x1.5 Sq mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible) copper conductor cable in PVC Casing & capping along with 1 no.,4sq mm HRFRLS/PVC insulated single core copper conductor cable as required including carriage of materials within all leads and lifts. |
| 34 | Wiring for circuit /sub main wiring with 4x1.5 Sq mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible) copper conductor cable in PVC Casing & capping along with 2 no.,2.5sq mm (4x2+5+2x2.5)HRFRLS/PVC insulated single core copper conductor cable as required including carriage of materials within all leads and lifts. |
| 35 | Supplying and fixing metal box of 100 x100 x 60mm deep (Nominal size) on surface/recess with suitable size phonolic leminated sheet cover fixing 3 pin 15/16 amps socket tumber/ piano type switch connections painting etc including carriage of materials within all leads and lifts. |
| 36 | S/F of 6 Amps to 32 Amps rating 10 KA breaking capacity 240 Volts, \\"C\\" curves miniature circuit breaker of following poles in the existing MCB DB complete with connections testing and commissioning etc as required including carriage of materials within all leads and lifts Category -A single pole. |
| 37 | Supplying and fixing 40 Amps/50 Amps/63 Amps rating 10 ΚΑ breaking capacity 240 Volts \\"C\\"curves miniature circuit breaker of following poles in the existing MCB, DB complete with connections, testing and commissioning etc as required including carriage of material within all leads and lifts Double pole Category-B 63 Amps. |
| 38 | Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts,on surface/recessed complete tinned, copper busher neutral link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing etc. as required bus bar 8 way |
| 39 | Providing, installing, testing and commissioning of 2x36 watt -CFL surface mounting (categary \\"A\\" including wiring with 1.5 Sq mm PVC insulated copper conductor single core cable etc.as required |
| 40 | Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length(upto 30 cm) with 1.5 Sqmm PVC insulated copper conductor single core cable etc.as required1200mm sweep Category A. |
| 41 | Providing, installing, testing and with 1.5 Sq mm commissioning of 1x36 watt -FTL (T8) shock proof slim (categary \\"A\\" including wiring PVC insulated copper conductor single core cable etc.as required. Please Enable Macros to View BoQ information |