| 1 | Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed. |
| 2 | Dismantling floor hearth or wall tiling and stone slabs including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed |
| 3 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded pointed in any mortar and removing rubbish off the premises etc complete all as specified and directed |
| 4 | Taking down chowkhats or frame with shutters (without taking off shutters from frames) exceeding 1.5 sqmtr but not exceeding 4 sq m each, complete all as specified and directed. |
| 5 | Taking down steel windows of any description and size and removing from site complete all as specified and as directed. |
| 6 | Demolition of brickwork built in cement mortar and removing rubbish off the premises etc complete all as specified and directed |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 8 | Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retrieved debris as directed including necessary scaffoldings etc complete all as specified and directed |
| 9 | Materials and Labour for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410-W (Gde-E- 250) quality-A/Fe.290.Gde-E-165 including painted one shop coat of zinc chromate primer paint (including preparation of surface) at workshop before fabrication complete all as specified and as directed. |
| 10 | Supply and fixing Pre-painted galvalume aluminum zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 11 | Supply and fixing Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed. |
| 12 | Materials and labour for preparing of new wooden surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 13 | Materials and labour for preparing of newly primed steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 14 | Materials and labour for preparing of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 15 | Materials and labour for preparing of old painted steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 16 | Materials and labour for Vitrified Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 15 mm th screed bed in CM 1:6 complete all as specified and as directed. |
| 17 | Materials and labour for Vitrified Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical serfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 10mm thick backing coat in cement mortar (1:4) , complete all as specified and directed. |
| 18 | Materials and labour for chequered cement concrete tiles 30cm x 30 cm size, 25 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry in floor with grey cement mixed with pigments to match with the colour of tiles, laid over and including 20 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 19 | Materials and labour for Kota stone slab 20-25mm thick in riser of steps,skirting,dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thick backing coat in cement mortar (1:3) including rubbing and polishing complete. |
| 20 | Materials and labour for Kota stone slab 20-25mm thick in floor laid over and including 20mm thick screed bed or bedding layer of cement mortar (1:6)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. |
| 21 | Materials and labour for 25 mm thick PCC (1:2:4) type B0 using 12.5 mm graded stone aggt as in floors finished even and smooth with using extra cement, complete all as specified and directed. |
| 22 | Materials and labour for brick work with fly ash bricks modular size, straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 23 | Materials and labour for brick work with fly ash bricks modular size straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 24 | Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed. |
| 25 | Supply and fixing 105 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hings lock strike plate etc complete all as specified. |
| 26 | Supply and fixing 165 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified. |
| 27 | Supply and fixing flush door shutters 30mm thick solid core construction, with block board core and both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed. |
| 28 | Supply and fixing 35mm thick second class hard wood glazed and skeleton shutter, open rebated and prepared to receive glass gauze etc, divided into squares (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass exc., size of members of shutter as specified in SSR part-I, sec 8 clause 8.24(a), supplied and fitted to chowkats, complete all as specified and directed. |
| 29 | Supply and fixing stainless steel barrel tower bolts 150 mm long, complete all as specified and directed. |
| 30 | Supply and fixing stainless steel handles 150 mm size , complete all as specified and directed. |
| 31 | Supply and fixing for 300mm long stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet complete all as specified and directed. |
| 32 | Supply and fixing CP curtain rails 20 mm dia chromium plated, with and including fixing brackets, stops, rollers etc, complete al as specified and directed. |
| 33 | Supply and fixing Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, including one coat of red oxide primer complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 34 | Supply and fixing 4 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane , complete all as specified and directed. |
| 35 | Supply and fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 36 | Materials and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 37 | Materials and labour for rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 38 | Materials and labour for rendering 20mm thick in two layers of 10 mm thick each in cement mortar (1:4) on fair faces of brick work or concrete surfaces,WPC shall be mixed with morter of top layer, finished even and fair, complete all as specified and directed. (Note: WPC shall be measured and paid separately as supply only) |
| 39 | Supply only liquid Water Proofing Compound of approved make. |
| 40 | Materials and labour for applying three coats of white wash on new ceiling surface including preparation of surface, complete all as specified and directed. |
| 41 | Materials and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour with roller over one coat of alkali resistant primer after preparation of surface complete all as specified and directed. |
| 42 | Materials and labour for for preparing of new plastered surface of walls and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Complete all as specified and directed (Note:- Rate should include rates for necessary H Frame and scaffolding arrangements) |
| 43 | Materials and labour for preparation old decorated surfaces of ceiling including brooming down or steel wire brushing scraping down smoke shoot, moulds, moss and efflorescent salt sand trading oil and greasy spots and applying two coats of white wash complete all as specified and directed. |
| 44 | Materials and labour for for preparation of old decorated surfaces of walls including brooming down or steel wire brushing scraping down smoke shoot, moulds, moss and efflorescent salt sand trading oil and greasy spots and applying one coat of oil bound distemper of approved colour with roller complete all as specified and directed. |
| 45 | Materials and labour for complete removal of existing treatment from wall surfaces and applying two coats of oil bound distemper with roller over one coat of primer of approved colour after preparation of surface complete all as specified and directed. |
| 46 | Surface Preparation work prior to water proofing treatment of RCC roofs completely as directed, surface to be free from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating primer, the surface thoroughly washed with water including removal of all existing treatment, bituminious membrane, tarfelt.screed concrete etc from RCC roof slab. |
| 47 | Materials and Labour for plain cement concrete (1:2:4) type B-0, using 12. 5 mm graded crushed stone aggregate over roof slab to achieve required slope including formwork making rounded chamfered on edges mixed with WPC @ 2% by weight of cement, complete all as specified and directed. Note: WPC shall measured and paid separately. |
| 48 | Materials and labour for 10 mm thick rendering in cement mortar (1:4) over RCC roof surface to receive roof treatment finished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instruction over brushing neat cement slurry with 3.0 kg of cement per sq metre (WPC shall be measured and paid separately). |
| 49 | Materials and labour for application of waterproofing Coating on RCC roofs with following steps of work to be carried out through authorised person/applicator of manufacturer:- : Providing and applying single component High build fibre Reinforced Acrylic Waterproofing render for roofing system to be applied by brush, at three coats at minimum dry film thickness of 1 mm, which should cure by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane.Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2 h |
| 50 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Please Enable Macros to View BoQ information |
| 51 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Please Enable Macros to View BoQ information |