| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER BAREILLY Name of Work: CONVERSION OF OVERHEAD CONDUCTOR INTO UNDERGROUND CABLE WITH CONNECTED WORKS AT CSD DEPOT BAREILLY UNDER GE (WEST) BAREILLY Contract No : CWE / BLY / GE(W) /38 OF 2026-27 Bidder Name : SCHEDULE A(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete including bricks all as specified & directed. |
| 3 | Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed. |
| 4 | Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. |
| 5 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 4 core complete all as specified and directed. |
| 6 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 2 core complete all as specified and directed. |
| 7 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 16 sqmm 2 core complete all as specified and directed. |
| 8 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 35 Sqmm 3½ core complete all as specified and directed. |
| 9 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 50 Sqmm 3½ core complete all as specified and directed. |
| 10 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 150 Sqmm 3½ core complete all as specified and directed. |
| 11 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 185 Sqmm 3½ core complete all as specified and directed. |
| 12 | Supplying & Laying old size clay brunt brick sub class B class complete all as specified and as directed |
| 13 | M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of calbe in trenches complete all as specified and directed. |
| 14 | Cutting of floor/ wall/ road/ footpath for removal of LT U/G cable of any size/ description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed. |
| 15 | S&F of GI pipe light grade 80mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed. |
| 16 | S&F of GI pipe light grade 50mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed. |
| 17 | M&L for PCC (1:4:8) type D2 using 40 mm graded aggregate as in foundations, filling and mass concrete etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed. |
| 18 | M&L for PCC (1:3:6) type C2 using 40 mm graded aggregate as in foundations, filling and mass concrete etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for galvanized earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using glavanised iron strip 25x4mm by means of bolts, nuts, check nuts and washers made of MS and protected by light grade 40mm dia and 20mm dia bore for watering and incl funnel, wire mesh RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (incl excavation and earth work, disposal of surplus soil to a distance not exc 50 mtr) all as specified and shown on Plate No 3 of SSR Part-I 2009. |
| 20 | S&F Galvanised iron strip 25 x 4mm for connection of earthing with DBs and LT Panel etc. directly burried in ground complete all as specified and directed. |
| 21 | S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminious paint on embedded surface incl writing of Pole Numbers etc., and marking of two black & two yellow strips with synthetic enamel paint upto 1.2 Mtr height and making good disturbed surface complete all as specified and directed. |
| 22 | S&F PVC insulated unarmoured & PVC sheathed copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from Sheet metal enclosure to light fittings including with suitable size copper lugs complete all as specified and directed. |
| 23 | M&L of Galvanised Steel Tubing Pipe 32mm bore 60 Cm in length (02 Nos), light grade with PVC long Bends 300mm long for Incoming and Outgoing Cables, grouting in Cement Concrete, Complete all as specified and as directed. NOTE : Cement Concrete will be measured and paid for separately. |
| 24 | Supply and fixing of brackets made out of 32 mm dia light grade GI Pipe 1.50 mtr long bent to shape and size fixed on location using new 30 x 5 mm GI clamps- 02 Nos made to shape incl nuts, bolts & washersof suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge. |
| 25 | S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 26 | S&F cable Junction box of size 254mm x 180mm x 111mm weather proof, IP 66/67 for outdoor installation including 05 Nos terminals fixing on street light pole using GI Clamps of size 30 x 5mm (02 Nos each pole) with suitable size of nuts, bolts & washers etc. with MCB SP, 6 Amps, 240 volts, 50 Hz - 01 No. complete all as specified and directed. |
| 27 | Supply, fixing, testing and commissioning of epoxy type End Termination jointing kit suitable for LT cable of size up to 10 to 16 Sqmm, 3.5 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed. |
| 28 | Supply, fixing, testing and commissioning of epoxy type End Termination jointing kit suitable for LT cable of size up to 25 to 50 Sqmm, 3.5 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed. |
| 29 | Supply, fixing, testing and commissioning of epoxy type End Termination jointing kit suitable for LT cable of size up to 70 to 150 Sqmm, 3.5 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed. |
| 30 | Supply, fixing, testing and commissioning of epoxy type End Termination jointing kit suitable for LT cable of size up to 185 to 240 Sqmm, 3.5 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed. |
| 31 | Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1400 mm x 1200 mm x 500 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of 600 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 75 x 75 x 6 mm with 600mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- |
| 32 | (a) MCCB with thermal-magnetic release of cap 320 Amp, FP, 50 Hz, 36 KA with spreader terminals - 01 Nos (I/C).(b) MCCB with thermal-magnetic release of cap 160 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (O/G).(c) MCCB with thermal-magnetic release of cap 100 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (O/G).(d) MCCB with thermal-magnetic release of cap 63 Amp, FP, 50 Hz, 25 KA with spreader terminals - 02 Nos (O/G).(e) MCCB with thermal-magnetic release of cap 40 Amp, FP, 50 Hz, 25 KA with spreader terminals - 04 Nos (O/G).(f) MCCB with thermal-magnetic release of cap 20 Amp, FP, 50 Hz, 25 KA with spreader terminals - 02 Nos (O/G).(g) Digital Amp Meter with selector switch -1 No(h) Digital Volt Meter with selector switch -1 No(j) LED type indication lamp RYB-1 set.(set of 03)(k) MCB SP 6 Amps, 10KA for Contrillong - 03 No's (l) CT's 250/5A - 03 No's(m) Digital Time Switch 3 Phase - 02 Nos(n) 3 Pole Powe Contactor, 3 Phse, 415 Volts - 02 Nos(0) Digital Energy Meter 10-60 Amps, 3 Phase, 4 wire, 415 volts, accuracy class 1.0 with GPRS/4G module -01 No. |
| 33 | Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 900 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/ change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of 200 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 50 x 50 x 6 mm with 450mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- (a) MCCB with thermal-magnetic release of cap 125 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (I/C).(b) Digital Amp Meter with selector switch -1 No(c) Digital Volt Meter with selector switch -1 No(d) LED type indication lamp RYB-1 set.(set of 03)(e) MCB SP 6 Amps, 10KA for Contrillong - 03 No's (f) CT's 100/5A - 03 No's |
| 34 | Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 900 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of 200 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 50 x 50 x 6 mm with 450mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- (a) MCCB with thermal-magnetic release of cap 100 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (I/C).(b) Digital Amp Meter with selector switch -1 No(c) Digital Volt Meter with selector switch -1 No(d) LED type indication lamp RYB-1 set.(set of 03)(e) MCB SP 6 Amps, 10KA for Contrillong - 03 No's (f) CT's 100/5A - 03 No's |
| 35 | Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 900 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of 200 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 50 x 50 x 6 mm with 450mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-(a) MCCB with thermal-magnetic release of cap 63 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (I/C).(b) Digital Amp Meter with selector switch -1 No(c) Digital Volt Meter with selector switch -1 No(d) LED type indication lamp RYB-1 set.(set of 03)(e) MCB SP 6 Amps, 10KA for Contrillong - 03 No's (f) CT's 63/5A - 03 No's |
| 36 | Dismantling of old OH ACSR Conductor of AAC Conductor complete all as specified and directed. |
| 37 | Dismantling of old insulators of any size/type complete all as specified and directed. |
| 38 | Dismantling of old cross Arms /MS Channels or Angle Iron of sny size complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |