| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed. |
| 2 | Demolition of Cement concrete (including cutting of reinforcement if any) in any description and any position not otherwise specifically provided for and removing debris out of MD land, complete all as specified and as directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), including removing broken tiles and the all rubbish off from the premises complete all as specified and directed. |
| 4 | M&L for 25 mm thick Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring, including. finishing the surface even & rough to receive tiling etc., complete all as specified and directed. |
| 5 | M&L for glazed colour ceramic tiles digital series(premium quality) area exceeding 0.13 sqm but not exceeding 0.18 Sqm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including 10mm thick backing coat in CM (1:4), complete all as specified and directed. |
| 6 | M&L for non skid ceramic coloured tiles, digital series (premium quality) of size 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.36 Sqm, (size & shape, shade and pattern as approved by GE), as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed |
| 7 | M&L for double charged Vitrified Ceramic tiles, 9-10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 1.8 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 8 | M&L for treating the surface of terrazzo tile , marble, granite, kota stone flooring etc with & including grinding rubbing with beeswax polishing into mirror finish complete all as specified and directed |
| 9 | M&L for 15-18mm thick machine cut Udaipur green marble, (size & shape, shade and pattern as approved by GE) as in cooking platform, over & including 15mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, rubbing with beeswax polishing into mirror finish and rounding the edges, complete all as specified and directed. |
| 10 | M&L for 18 to 20 mm thick (telephone black shade) granite stone, as in WHB counter top, steps, jambs, pillars, window cills & similar nature works, machine cut,(table rubbed and polished) best quality as per sample, over & including 15 mm thick screeding in CM1:4 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.& providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed. |
| 11 | M&L of 18-20mm thick machine cut KOTA stone slab as in floor (size not less than 580mm x 580mm) , treads, steps etc(Single piece for steps), machine cut,laid over & including 15mm thick in screed bed in CM (1:6) and jointed with grey cement slurry with pigment to match the shade of the slab,including grinding, rubbing with beeswax polishing into mirror finish complete all as specified & directed. |
| 12 | M&L of 18-20mm thick machine cut KOTA stone slab as in riser of step , skirting, dado etc(Single piece for steps), machine cut, laid over & including backing coat of 10mm thick in CM (1:4) and jointed with grey cement slurry with pigment to match the shade of the slab, including grinding, rubbing with beeswax polishing into mirror finish complete all as specified & directed. |
| 13 | Dismantling wall and ceiling boarding, any description,including frame work & cover fillets etc., fixed in any position with nails/screws complete all as specified and directed. |
| 14 | M&L for GI frame work for seamless ceiling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c inteRunning Metreediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2M length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intemediate channel with connecting clips across the intermediate channel at 457mm c/c and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and including supply and fixing 12mm thick gypsum board as in ceiling fixed with screws as per manufacturers instructions and applying two coat of oil bound distemper over a coat of 2.0 mm wall care putty complete all specified and as directed. |
| 15 | S & F for providing aluminium snap grid frame work for false ceiling system with size 605 mm x 605 mm, consisting of main runner of size 36.5 mm x 25 mm x 1.4 mm (weight not less than @ 0.24 Kg/Rm) and cross Tee of size 23.5 mm x 36.4 mm x 1.4 mm (weight not less than @ 0.191 Kg/Rm). The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40 mm X 25 mm X 2 mm (weight not less than @ 0.36 Kg/Rm).The snap grid shall be fixed to ceiling supporting hangers consisting of 6 mm dia. G.I wire , J-bolts ,nuts and washers as per manufacturer's instructions or adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and complete all as specified and directed by Engr-in-Charge |
| 16 | S&F Exposed metal frame ceiling with 6mm thick calcium silicate board (both side laminated) of siliceous and calcareous material reinforced with cellulose fibre and liminated both side for fixing in 600 mm x 600mm grid, complete, as specified and directed.Note:- Frame work for ceiling shall be measured and paid separately. |
| 17 | M&L for PVC (Polyvinyl schloride) wall panelling made out of PVC hollow core sheet overall size of panel is 3 mtr in length and 0.3 mtr in width, 8 mm overall thick with tongue and Groove style interlocking arrangment to wall including all necessary arrangment complete all as specified and directed |
| 18 | S&F of gear operated type with bevel gear box and crank handle type Steel rolling shutters, of 1.00 mm thickness of laths as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, including taking down existing rolling shutter complete all as specified and directed |
| 19 | S&F in repairs safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed |
| 20 | S&F in repairs ball bearing for rolling shutters complete all as specified and directed |
| 21 | Taking down and refixing in the same openings of steel rolling shutter any type and any thickness of laths including replacement of old rusted laths and fixing of other assessories, if required to operated smooth function after repairing complete all as specified and as directed |
| 22 | Taking down carefully cement concrete/spalled out concrete from RCC roof projections, ceilings, sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scaffolding etc, complete all as specified and directed. |
| 23 | M&L for cleaning the existing reinforcement of slabs , chajjas etc & applying a coat of SIKA RUSTOFF 11 to remove the loose rust particles etc & throughly cleaning the surface, complete all as specified and directed. |
| 24 | M&L for applying a coat of bond coat made with cement slurry (1 part cement to 1.5 -2 parts water) mixed with admixture LATEX POWER mixed @5 Kg per 50 kg of cement & applying to the concrete surfaces @ 200 gm/ Sqm to obtain tack, complete all as specified and directed. |
| 25 | M&L for 15 -20 mm thick rendering in CM 1:1:2(using1 part of cement ,1 part 2-3 mm screenings of stone agg & 2 parts coarse sand ) over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & rough to receive final rendering coat, complete all as specified and directed. |
| 26 | M&L for 5 mm thick rendering in CM 1:3 & finishing the surface even & smooth w/o using extra cement, complete all as specified and directed. |
| 27 | S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc., complete all as specified and directed. |
| 28 | Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land, complete all as specified and directed. |
| 29 | M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed. |
| 30 | M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6,but except stone complete all as specified and directed., |
| 31 | Extra over stone walling for hammer dressing to face stone & dressing of face beds & joints as specified of squared rubble walling Jodhpur type brought upto courses with maximum depression of face from straight edge held against the dressed surface not exceeding 20mm and dressing face beds and joints, complete all as specified and directed. |
| 32 | M&L precast cement concrete (1:2:4) type B-1(using 20mm graded crushed stone aggregate) as in solid block masonry,10cm thick and setting in cement mortar 1:4 complete all as specified & directed by Engineer-in-charge. |
| 33 | M&L precast cement concrete block masonry using PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. |
| 34 | Taking down cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed. |
| 35 | M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed. |
| 36 | M&L for 10 mm thick rendering in CM 1:4 on fair faces of brick work or conc surfaces as in ceilings/chajja/facia & finished even & smooth w/o using extra cement, complete all as specified and as directed. |
| 37 | M&L for racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed. |
| 38 | M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed, complete all as specified & directed. |
| 39 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed . Please Enable Macros to View BoQ information |
| 40 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed . Please Enable Macros to View BoQ information |