| 1 | M&L for Preparation of old plastered surfaces of walls including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and applying one coats of cement base paint with fully automatic airless spray machine of paint application with a flow speed of min 1 lts per minute having a pressure including at any height (not.exc 11mtr )incl necessary scaffolding /Centreing etc complete all as specified and directed. |
| 2 | M&L for Preparation of old plastered surfaces of walls including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots on surface of wall and applying two coats of cement base paint of approved colour with fully automatic airless spray machine of paint application with a flow speed of min 1 lts per minute having a pressure including at any height (not.exc 11mtr ) incl necessary scaffolding /Centreing etc complete all as specified and directed. |
| 3 | M&L for preparing old plastered or unplastered surfaces of walls and applying one coats of Acrylic weather proof Exterior paint (Apex paint) on walls or concrete surfaces at any height (not.exc 11mtr) complete all as specified and directed. |
| 4 | M&L for preparing old plastered or unplastered surfaces of walls and applying two coats of Acrylic weather proof Exterior paint (Apex paint) on old plastered or old plastered surfaces of walls or concrete surfaces at any height (not.exc 11mtr) complete all as specified and directed. |
| 5 | M&L for preparing old plastered or unplastered surfaces of walls by brooming down or by steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and applying one coats of oil bound distamper complete all as specified and directed. |
| 6 | M&L for complete removal old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper including over a coat of 2 mm thick wall care putty complete all as specified and directed. |
| 7 | M&L preparing old surfaces of ceiling and applying two coat of white wash on ceiling surface complete all as specified. |
| 8 | M&L Preparing old surfaces and applying one coat of white wash on ceiling surface completel all as specified. |
| 9 | M&L Preparing old plastered or unplastered surfaces and applying one coat of white wash / colour wash and including add necessary synthetic adhesive lime binder as per manufactruer instructions on wall surfaces complete all as specified and as directed |
| 10 | M&L Preparing old plastered or unplastered surfaces and applying two coat of white wash and including add necessary synthetic adhesive lime binder as per manufactruer instructions on wall surfaces complete all as specified and as directed |
| 11 | M&L for preparation of old painted steel surfaces & applying one coat of synthetic enamel paint on steel surface of any description over 10 cm in width or girth complete all as specified and as directed. |
| 12 | All as per item No 11 above but two coats synthetic enamel paint on steel complete all as specified and as directed |
| 13 | M&L for preparation of old painted wood and wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 14 | All as per item No 13 above but two coats synthetic enamel paint on wooden surfaces complete all as specified and as directedNote:- (a) For Item No 01 to 14 All the Materails to be Brought by Contractor and store in one place as per direction by Engr-in charge/GE. (b) Cleaning of windows/doors during spray painting using polythene film will be included.(d) Rate quotated includes work at any height (not.exc 12mtr) incl necessary scaffolding /Centreing etc and cleaning the waste materials and debris from out of MoD land etc complete as directed. |
| 15 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc all as directed. |
| 16 | M&L for 10-12 mm thick smart care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer's instructions) over Interior surfaces walls and applyingTwo coats of acrylic distemper (ready mixed) having VOC content less than 50 gms/litre on new work a coat of 2mm thcik wall interior wall care putty on wall surfaces complete and sanding of the putty surface with sand paper or other means by skilled labour and to make the surfaces smooth and free from dust etc. complete all as specified and directed |
| 17 | M&L for 10-12 mm thick smart care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer's instructions) over exterior surfaces walls and applying two coat of cement based paint over alkali resistant primer complete all as specified and as directed. |
| 18 | M&L for Rendering 10 mm thick plastering in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for preparation of newly plastered ceiling surface and applying three coats of white wash, complete all as specified and directed. |
| 20 | Demolition and breaking up drain PVC (SWR) pipes jointed in cement mortar/solvent, internal dia of pipe upto 110mm in any position with wall or in floor etc. |
| 21 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed.. |
| 22 | S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed. |
| 23 | S&F 75 mm PVC (SWR) bends any radius with acess door complete all as specified and directed. |
| 24 | S&F 110 mm PVC (SWR) bends any radius with acess door complete all as specified and directed. |
| 25 | M&L for Providing and Repairing the damaged concrete portion / Surface preparation with single component ready to use, repair mortar SMARTCAE REPAIR MORTAR capable of applying 20 mm avg. thick in single layer initially by hand and finishing with trowel, carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface complete all as specified and directed. |
| 26 | M&L for Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire surface of bars free from loose torn metallic parts, loose material, dirt etc. and M&L for applying alkaline Antioxydizing agent on the existing rebars and allowing it to react with damaged metal and form a corrosion resistant, insoluble protective layer, as per manufacturer's instructions, including necessary scaffolding, props etc. complete all as specified and as directed. (Mode of measurement: per sqm of breaking area of concrete.) |
| 27 | M&L for Providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) complete all as specified and as directed. The rate shall include cost of scaffolding necessary for the work etc. complete all as specified and as directed. |
| 28 | M&L for Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C complete all as specified and as directed. |
| 29 | M&L for mixing mechanically PP fibre of 12 mm length with Anti-crack strength in red mix repair mortar with suitable care to ensure dispersion of fibres conforming to ASTM C 1116/C, 1116M-10a 4.1.3 type3 & BS EN14889-2.2006 and providing 20 mm thick one component chloride free thixotropic fibre reinforced polymer modified repair mortar at external brick wall with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 in cement mortar in the ratio 1:4 mixed with styrene butadiene polymerized cement mortar modifier or AR for bonding with Cement mortar specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents) not less than 2% by weight of cement and as per manufacturer’s Instructions. For external columns or any brick or stone wall surface etc. |
| 30 | M &L for curing of the surface using wax based Concrete curing compound CC 75 curing efficiency; CC 75 complies with the internationally recognized ASTM C309-90 standards incuding all tools and tackles. |
| 31 | M&L for Providing and applying one coat of Solvent based compound having Electrochemical impedance of 107 Ω and achieving dry film thickness of minimum 80 microns per coat with UV condensation of Min 100 Hrs. Elastomeric, Anti carbonation, Anti corrosive, UV resistant , Pure Aliphatic Acrylate System- on the exterior faces of Buildings Protection against ION penetration, carbonation,UV radiations and wethering effect conforming to ASTM D 4541-02 a primer coat using brush or spray after complete cleaning & removal of oil, grease or loose particles from the surface etc. complete all as specified and directed.Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer. |
| 32 | M&L for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water & allow to dry. Fill visible cracks/ joints by chemistic crack seal caulking compound & allow to dry for 24 hours. Apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours. Thereafter apply 02 coats of weathercoat glow (WB high build anti carbonation coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed. |
| 33 | M&L Formwork to sides of rough finish surfaces of concrete pillars, posts, struts, piers, columns, and stanchions fair finished surfaces of concrete etc all as specified and directed. Please Enable Macros to View BoQ information |