| 1 | Construction of Goat Shed |
| 2 | Excavation for foundation in earth,soil of all types, sand, gravel and soft murum , including removing the excavated material up to a distance of 50 m.beyond the building area & stacking and spreading as directed,dewatering ,preparing the bed for the foundation. |
| 3 | Filling in plinth and floors with approved excavated material in 15cm to 20cm layers, including watering and compacting, etc. Complete. |
| 4 | Providing soiling using 80 mm.size trap metal in 15 cm layers including filling voids with crushed sand/ grit ramming ,watering complete Spec. No. As |
| 5 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided |
| 6 | (FOOTING CONCRETE ) Providing and laying cast in-situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage, and footings of R.C.C. columns and steel stanchions, etc. including bailing out water, steel centering, formwork, cover blocks, laying/pumping, compaction, and curing, roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 7 | ( COLUMNS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided, and curing, etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 8 | ( PLINTH BEAMS CONCRETE ) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, and roughening the surface if special finish is to be provided, and curing, etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 9 | Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches, etc. as per detailed designs, drawings, and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding, and supporting as required, complete. |
| 10 | TREMIX FLOOR CONCRETE WORK ) Providing and layingin situ cement concrete M20 with TREMIX TREATMENT for 100 MM thickness for flooring with groove cutting of 4mm wide and 20 mm deep with necessary refilling with bitumen etc. complete. |
| 11 | (Brick Work) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls, including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces, and watering, etc. Complete |
| 12 | Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.comp lete ( excluding cost of structu |
| 13 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days an |
| 14 | Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specification |
| 15 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making ri |
| 16 | Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min |
| 17 | Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel wi |
| 18 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. Bd.0.8 Page |
| 19 | Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C |
| 20 | Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 kg. to 20 kg. Per Sq.m.)Spec.No.: As directed by |
| 21 | Royalty 80 mm Metal |
| 22 | Hard Murum |
| 23 | Lab test Cement - Fineness, Standard Consistency, Setting Time (Initial & Final ), Compressive strength, Soundness |
| 24 | Concrete M-10, M-20 grade - Concrete cube compressive strength (Set of 3 Cubes) |
| 25 | Crushed metal - Water absorption, Specific gravity,Impact value,Crushing value |
| 26 | Brick - Crushing value, Water absorbation, & Specific Gravity |
| 27 | tubular steel structure (shed) - Tensile strength ,Yield stress, ultimate tensile stress, %elongation, weight per running meter,Bend/Rebend test.(Set of 3 Bars) |
| 28 | Murum - Plasticity Index |
| 29 | Murum - Field Density of compacted layer ( Proctor Density Test ) |
| 30 | Sand Test -Sieve Analysis |
| 31 | ELECTRICAL WORKS Providing and fixing lioghtening conductor system comprising of erecting Air - Termination consisting of tubular copper rod of 25 mm dia.1.2 mm thick with multiple point shead 1.2mt.long (Heavy Duty)welded or clamped to G.I. pipe pole B grade 50 mm dia of required length with M.S . round base plate 25 Cm diamand 10 mm thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 cm dia m x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cad mium plate nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and G.I. pipe 40 mm dia2 meter length burried in earthing plate remining portion above ground level for watering and refilling comcpete Note-Copper strip from lightening conductor is not considered in this item. |
| 32 | Providing and fixing copper strip 25 mm wide and 3 mm thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthin pits is not considered in this item |
| 33 | Supplying and errecting HMS PVC conduit FRLS Grade 25 mm dia. With pvc accessorieson wall/ ceilling as per specification No. WG-MA/ CON |
| 34 | Supplying and errecting mains with 1X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any otherplaces as per specification No. WG-MA/CON |
| 35 | Supplying and errecting mains with 2X1.5 sq. mm. FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/Buss bars or any other places as per specification No. WG-MA/CON |
| 36 | Supplying and errecting mains with 2X2.5 sq. mm. FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/Buss bars or any other places as per specification No. WG-MA/CON |
| 37 | Supplying and errecting modular type 3pin 6/16 A multy sockets with safetyshutter, duly errected on provided plate and box with wiring connections complete |
| 38 | Supplying and errecting PVC surface maodular switch box with doublemounting plate for 6 module duly errected |
| 39 | Supplying and errecting PVC surface maodular switch box with doublemounting plate for 12 module duly errected |
| 40 | Supplying and errecting street light wall bracket made from 40 mm dia G I pipe1.2 m in total length complete as per specification no FG- BKT/WB |
| 41 | Supplying, errecting and marking SPMCB 6A to 32 A, C series with rated short -circuit braking capasity 10kA in provided distribution board as per specification no SW-SWR/MCB |
| 42 | Providing earthing with galvnised iron earth plate size 60 X 60 C 0.6 cmcomplete with all materials, testing and recording the resuilt as per specification no EA-Ep |
| 43 | Prviding and managing 20 Trees in the same premises, under Management Strategies And Implementation Plan ( MSIP ) to Manage Environmental , Social , Health And Safety. Please Enable Macros to View BoQ information |