|
| 1 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 2 | Granite stone slab of colour black, Cherry/Ruby red |
| 3 | Area of slab upto 0.50 sqnn |
| 4 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 5 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 6 | 250x16 mm |
| 7 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 8 | 200x10 mm |
| 9 | 100x10 mm |
| 10 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 11 | 100 mm |
| 12 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 13 | Providing and fixing to existing door frames. |
| 14 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 15 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 16 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 17 | Size of Tile 600 x 600 mm |
| 18 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 19 | 75 mm diameter |
| 20 | 110 mm diameter |
| 21 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 22 | Single tee without door |
| 23 | Bend 87.5° |
| 24 | 110 mm bend |
| 25 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 26 | 110 mm |
| 27 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour |
| 28 | Old work (one or more coats) |
| 29 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 30 | Rectangular shape 1500x450 mm |
| 31 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 32 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 33 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 34 | 15 mm nominal bore |
| 35 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 36 | 15 mm nominal bore |
| 37 | Providing and fixing PTMT grating of approved quality and colour. |
| 38 | Circular type |
| 39 | 125 mm nominal dia with 25 mm waste hole |
| 40 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 41 | 100x100 mm size P type |
| 42 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 43 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 44 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 45 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : |
| 46 | Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5 |
| 47 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 48 | For fixed portion |
| 49 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 50 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 51 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 52 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 53 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 54 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: |
| 55 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, and C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia other couplings in C.P. brass, including cutting and making good the walls and floors wherever required. |
| 56 | Deduct GST Factor on total of SR & DR items i.e 253587.84 x 0.973 = Rs. 246740.97-253587.84 = -6846.87 |
| 57 | Add Cost index @ 4.03% on SR&DR items =246740.97 |
| 58 | Electrical Work |
| 59 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 60 | Group A |
| 61 | Group C |
| 62 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 63 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 64 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 65 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 66 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 67 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 68 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 69 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 70 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 71 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 72 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 73 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. |
| 74 | Group A |
| 75 | Group C |
| 76 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 77 | Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 78 | 1 x 1.5 sq. mm |
| 79 | 2 x 1.5 sq. mm |
| 80 | 3 x 1.5 sq. mm |
| 81 | 4 x 1.5 sq. mm |
| 82 | 5 x 1.5 sq. mm |
| 83 | 6 x 1.5 sq. mm |
| 84 | 9 x 1.5 sq. mm |
| 85 | 1 x 4 sq. mm |
| 86 | 3 x 4 sq. mm |
| 87 | 6 x 4 sq. mm |
| 88 | 3 x 6 sq. mm |
| 89 | 2 x 10 sq. mm + 1 x 6 Sq.mm |
| 90 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 91 | 20 mm |
| 92 | 25 mm |
| 93 | 32 mm |
| 94 | 40 mm |
| 95 | 50 mm |
| 96 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 97 | 5/6 A switch |
| 98 | 2 way 5/6 A switch |
| 99 | 15/16 A switch |
| 100 | 3 pin 5/6 A socket outlet |
| 101 | 6 pin 15/16 A socket outlet |
| 102 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 103 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 104 | 1 or 2 Module (75mmX75mm) |
| 105 | 3 Module (100mmX75mm) |
| 106 | 4 Module (125mmX75mm |
| 107 | 6 Module (200mmX75mm) |
| 108 | 8 Module (125mmX125mm) |
| 109 | 12 Module (200mmX150mm) |
| 110 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 111 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 112 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 113 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 114 | Group C |
| 115 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 116 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 16 amp modular socket outlet and 16 A /25 A modular SP MCB, \\"C\\" curve including connection, painting etc. as required. |
| 117 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 118 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 119 | 12 way , Double door |
| 120 | Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 121 | Single pole |
| 122 | Double pole |
| 123 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 124 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 125 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 126 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 127 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 128 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 129 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 130 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge. |
| 131 | Supplying and installation of PVC Exhaust fan with louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required.(Havells / C&G / Orient / Usha / Almonard/ Atomberg) |
| 132 | Supplying and installation of 300 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard) |
| 133 | Supplying and installation of 225/ 230 mm sweep, single phase, metallic exhaust fan in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Ventil Air or with similar specifications C&G / Orient / Usha / Almonard) |
| 134 | Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge. |
| 135 | 250 mm sweep. |
| 136 | 225 mm /230 mm sweep |
| 137 | Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc., complete as per the direction of the engineer-in-charge. |
| 138 | Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required. |
| 139 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 2400 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 140 | Supply, installation, testing and commissioning of surface mounted LED downlighter luminaire in metallic housing, with a minimum system lumen output of 1500 lumen and with a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required. |
| 141 | Supplying and fixing Plastic Batten/Angle holder alonwith 9/10 watt LED blub including connection etc. as required. |
| 142 | Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required. |
| 143 | 300 mm |
| 144 | Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required. |
| 145 | Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required. |
| 146 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 147 | 40 A Double pole |
| 148 | 63 A Double pole |
| 149 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 20 mm |
| 150 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 25 mm |
| 151 | Supplying and fixing of 23 mm x 1.5 mm S.S./G.I. saddles on the following sizes of existing PVC or steel conduit, cable, pipe, etc., as required (Astral, Prayag, Ashirvad, Finolex, or as approved by the engineer-in-charge)i) 50 mm |
| 152 | Supplying, installation testing and commissioning of BEE 5 star rating, 25 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty) |
| 153 | Supplying and fixing suitable size GI/ PVC box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 151/6 A modular switch, connections etc. as required. |
| 154 | Providing and erection of G.I. pipe medium class of the following diameter in the existing gate pillar for fixing the post-top lantern, including making holes and embedding the required length of the pipe in the pillar top, and making good the damage with matching concrete, plastering, and painting after the erection of the pipe, etc., complete as per the direction of the engineer-in-charge. |
| 155 | G.I. pipe 50 mm dia |
| 156 | G.I. pipe 65 mm dia |
| 157 | Supply, installation, testing and commissioning of 25 watts LED-based post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Make :CORAL (Opal) or RUBY (Clear) of Havells similar in Philips / Havells/ Wipro/ Bajaj |
| 158 | Supply, installation, testing and commissioning of 45 watts LED-based post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Make :CORAL (Opal) or RUBY (Clear) of Havells similar in Philips / Havells/ Wipro/ Bajaj |
| 159 | Supplying and fixing PVC weatherproof 20 A, 240 V, Switch box, IP66, complete with one 20 A switch on surface or in recess, complete with connections, testing and commissioning etc. as required.(Crabtree ACWCDIW201 /Hensel / Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO) |
| 160 | Supplying and fixing PVC weatherproof, IP66, 16 A, 240 V, switch and Socket box, IP66, complete with one 16 A switch and socket on surface or in recess, complete with connections, testing and commissioning etc. as required. (Crabtree ACWCKXW163/ Hensel / Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO) |
| 161 | Supplying and fixing polycarbonate weatherproof, IP66 outdoor type cable junction box with minimum dimensions of 155 mm x 210 mm x 92 mm on surface or recess, including connections etc., complete as required. ( Hensel KF 1600G/ Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO) |
| 162 | Supplying and fixing polycarbonate weatherproof, IP66 outdoor type cable junction box with minimum dimensions of 205 mm x 255 mm x 112 mm on surface or recess, including connections etc., complete as required. (Hensel KF 2500G / Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO) |
| 163 | Supplying and fixing Cable Junction Boxes, IP 66 weatherproof, size 155 mm x 210 mm x 92 mm with 5 Nos two-way terminals mounted on DIN rail suitable for termination of 16 sq mm cable, on the surface or in recess, complete, etc. as required.) (Make Hensel KF 1616G / Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO/SCHNEIDER ) |
| 164 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (Also embedding in cement concrete, cost of concrete to be paid separately) |
| 165 | Supplying and fixing a PVC cable gland suitable for following size copper conductor cable in the existing polycarbonate cable junction box, including connections, etc. as required. |
| 166 | Up to 6 sq mm |
| 167 | Supplying and fixing a PVC cable gland suitable for following size copper conductor cable in the existing polycarbonate cable junction box, including connections, etc. as required. |
| 168 | For 2 x 10/ 16 sq mm |
| 169 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armoured conductor power cable 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC pipe as required. |
| 170 | 2 X 16 Sq.mm |
| 171 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armoured conductor power cable 1.1 KV grade of following size in Masonry Open Duct Loose/loop/in panel etc. complete etc as required. |
| 172 | 2 X 16 Sq.mm |
| 173 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 174 | 2 X 16 sq. mm (22mm) |
| 175 | Supply and drawing of 3 x 2.5 sq mm PVC insulated, FRLS PVC sheathed copper conductor multi core flexible cable into the existing street light pole/ PVC conduit/ DWC Pipe / loose as per requirement including making connections etc., as required. |
| 176 | Supply and drawing of 3 x 1.5 sq mm PVC insulated, FRLS PVC sheathed copper conductor multi core flexible cable into the existing street light pole, PVC conduit/ DWC Pipe / loose as per requirement including making connections etc., as required. |
| 177 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc. as required |
| 178 | 50 mm dia nominal bore |
| 179 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 180 | 40 mm dia ( OD- mm & ID- mm Nominal) |
| 181 | 63 mm dia ( OD-63 mm & ID-51 mm Nominal) |
| 182 | Supplying and fixing polycarbonate weatherproof, IP66 outdoor type cable junction box with minimum dimensions of 155 mm x 210 mm x 92 mm on a pole, complete with the following accessories fixed in, and two sets of 25 mm x 3 mm GI clamps with G. I. bolts, nuts and washers, for mounting on a street light pole, including connections etc., complete as required. i) Din-rail suitable for fixing the following accessories- 1 Nos. ii) Feedthrough terminals 75 A - 4 Nos with endplate as required. iii) shorting link - 2 Nos.v) End Clamps - 2 Nosvi) SP MCB \\"C\\" curve, 10KA, 6 A - 1Nos.v) PVC Cable Gland - 2 Nos Junction box make: (Make Hensel KF 1600G / Legrand / CAPE/ ELM / GEWISS/ SPELSBERG / RITTAL/ EATON/OBO)Terminal Bock: Connect well/Elmex/ Phoenix/ Wago/ EssenCable Gland : Hensel/ Dowells/ Barco/ Connectwell/ Elmex /Eaton/ Legrand |
| 183 | The road crossings of power cable through trenchless boring. Trenchless boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required.The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition.Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department.The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length.i) Upto 150 mm dia DWC HDPE / G.I. /PVC |
| 184 | Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required. |
| 185 | Add labour cess @ 1% DSR 2022 (Elect.) 152704=1527.04 |
| 186 | Add Difference in GST of (18 & 12%)by MF 0.0633 0n DSR Elect |
| 187 | Less Cost Index on DSR € @-2.73% , 163993.86 = -4477.03 |
| 188 | Correction factor on existing items of DSR @ 0.973 as per CPWD office Memorandum 158/SE (TAS)/GST/2024/02-E DATED 8-8-2024 (U) = Rs. 168470.90 Please Enable Macros to View BoQ information |