| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc. of any description complete all as specified and as directed. |
| 2 | S&F Fe 410-W (GdeE- 250) quality A framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 3 | S&F steel rolling shutters of 1.25mm lath thickness, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle complete all as specified and as directed. |
| 4 | S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed. |
| 5 | S&F Ball bearing for rolling shutters complete all as specified and as directed. |
| 6 | M&L for preparing new or previously untreated surfaces applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 7 | M&L one coat of synthetic enamel paint (1st grade quality) to old decorated steel surfaces of girth exc 10cm including preparation of surfaces complete all as specified and as directed. |
| 8 | M&L PCC type C1, 1:3:6 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, hold fast blocks, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating all as specified and as directed. |
| 9 | Chipping of loose/ damaged / cracked / previously repaired/ delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and as directed. Note: The execution shall be carried out at height varying from ground floor to IInd floor upto roof level approx up to 15 mtr specially for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scaffolding and ladder complete all as specified and as directed. |
| 10 | M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height upto 3rd floor levels, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and as directed.Note: The execution shall be carried out at height varying from ground floor to IInd floor upto roof level approx up to 15 mtr specially for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scaffolding and ladder complete all as specified and as directed. |
| 11 | M&L for weld-mesh of size 50x50x3mm to be wrapped on the exposed surface of rib of beam, on the slab bottom etc and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or equivalent make in Fosroc / Themax as per manufacturer's instructions as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions and direction.Note: The execution shall be carried out at height varying from ground floor to IInd floor upto roof level approx up to 15 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scaffolding and ladder complete all as specified and as directed. |
| 12 | Providing and fixing water tight centering & shuttering and scaffolding including bolting, strutting, propping etc. including removal of form work from column, beam, slab and chajja etc. complete as per site requirement and directions.Note: The execution shall be carried out at height varying from ground floor to IInd floor upto roof level approx up to 15 mtr specially for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scaffolding and ladder complete all as specified and as directed. |
| 13 | Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product : SikaRep Microcrete-4 + adequate coarse aggregate, Yield:approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep Microcrete-4 or equivalent make in Fosroc/Thermax as approved by GE. Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99.Note: The execution shall be carried out at height varying from ground floor to IInd floor upto roof level approx up to 15 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scaffolding and ladder complete all as specified and as directed. |
| 14 | Taking down cement plaster on brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 15 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) and finished fair and even without using extra cement on ceiling all as specified and directed. |
| 16 | M&L 15 mm thick rendering in CM 1:6 on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 17 | M&L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 18 | Supply only integral water proofing compound. |
| 19 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.Note - Rate shall be quoted including sufficient scafolding, ladder etc. for 7 mtr height complete all as specified and as directed. |
| 20 | M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. Note - Rate shall be quoted including sufficient scafolding, ladder etc. for 7 mtr height complete all as specified and as directed. |
| 21 | M&L for preparing old plastered surfaces of walls and applying one coat of white wash on wall complete all as specified and directed. Note - Rate shall be quoted including sufficient scafolding, ladder etc. for 7 mtr height complete all as specified and as directed. |
| 22 | Demoliton of (RCC) reinforced brickwork in suspended slabs, beams, lintels etc. in cement mortar or cement concrete (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 23 | Demolition of cement concrete (un-reinforced) in any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 24 | M&L for 75 mm thick cement concrete 1:3:6 type C2, in plinth protection finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in Charge. |
| 26 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep as in foundation, etc, and getting out in soft/loose soil complete all as specified and directed. |
| 27 | M&L for brick work with sub-class ‘B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all as specified and directed. |
| 28 | M&L PCC type D2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete all as specified and as directed. |
| 29 | M&L 40mm thick damp proof course including WPC in CM (1:2:4 ) type B0 to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed. Note:- (WPC shall be measured & paid seperately as per manufacturer's instructions as printed on the container.) |
| 30 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm for soft/loose soil complete all as specified and directed. |
| 31 | M&L broken stone or boulders for hard core of guage n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 32 | M&L for 75 mm thick cement concrete 1:4:8 type D2, using 40mm graded stone aggregates as sub base to floor, complete all as specified and directed. |
| 33 | M&L for 25 mm thick cement concrete 1:2:4 type B1, using 20mm aggregate as in leveling course complete all as specified and directed. |
| 34 | M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed. Note : - Kota stone shall be of size 550mm x 550mm (minimum) when brought at site. |
| 35 | M&L for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado etc, laid over 10 mm cement mortar rendered in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and as directed. |
| 36 | M&L for TMT mild steel bars 10 mm dia and over, cut to shape required, including cranking, bending spirally for hooping for coulmns, hooking ends and binding with and including mild steel (annealed) not less than 0.9 mm dia or secuing with clips complete all as specified and directed. |
| 37 | M&L for TMT mild steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to shape required, including cranking, bending spirally for hooping for coulmns, hooking ends and binding with and including mild steel (annealed) not less than 0.9 mm dia or secuing with clips complete all as specified and directed. |
| 38 | Use and waste of formwork to rough finished flat surfaces of chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 39 | M&L for reinforced cement concrete nominal mix Type B1 1:2:4 (20 mm graded aggregate) for chajja/ sunshade over window and doors complete all as specified and as directed. |
| 40 | Use and waste of formwork to rough finished flat surfaces, sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed. |
| 41 | M&L for reinforced cement concrete nominal mix Type B1 1:2:4 (20 mm graded aggregate) for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 42 | Use and waste of formwork to rough finished flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed. |
| 43 | M&L for reinforced cement concrete nominal mix type B1 1:2:4 (20 mm graded aggregate) for slabs supported on walls, beams and collumns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like and all other similar works complete all as specified and directed. |
| 44 | M&L for preparing old decorated surface of wall/chajja and applying one coat of cement base paint on surface of wall/chajja all as specified and directed. Note :- Rate shall be quoted including sufficient scafolding, ladder etc. for 7 mtr height complete all as specified and as directed. |
| 45 | S&F for GI frame work for ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre with GI Cleat and steel expansion fasteners with and including ceiling section ( not exc. 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed tothe intermediate channel with connecting clips acrośs the intermediate channelat 45mm ceṇtre including 4mm thick non asbestos fibre cement building E boards fixed or laid/inserted toGI framework with screws for fixing in 600 mm x 600 mm grid, complete all as required at site complete all as specified and directed. |
| 46 | M&L for coloured chequred tiles, glossy finish, 25cm x 25cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & pigment, laid over & including 15mm thick screed bed in cement & sand mortar (1:4), complete, all as specified & as directed. |
| 47 | S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 48 | S&F in repairs Stainless steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 49 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 50 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including modular covered plated and frame all as specified & directed. |
| 51 | All as per item No. 50.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board. |
| 52 | All as per item No. 50.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. |
| 53 | All as per srl item No. 50.00 (here-in-before) but for 15 Amp socket out let by using 2.50 sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed. |
| 54 | S&F modular type switch , single pole, one way, 5/6 Amp, 230 Volts all as specified & directed. |
| 55 | S&F modular type switch , single pole, one way, 15 Amp, 230 Volts complete all as specified and directed. |
| 56 | S&F modular type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed. |
| 57 | S&F modular type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 58 | S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed. |
| 59 | S&F LED light fitting 1x20W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. |
| 60 | S&F in replacement LED recess mounting panels 2 feet x 2 feet luminaire of capacity 36 watt suitable to be fixed in ceiling having extruded aluminium frame and super bright LEDs complete all as specified and directed. |
| 61 | S&F in repairs of security light 25 watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. |
| 62 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 63 | S&F in repairs of factory made epoxy polyester powder coated distribution board TP & N 4 way (TPN DB) double door (IP-43 protection) fabricated from minimum 2.0 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for TPN as incommer and outgoing MCBs as required at site complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed. NOTE :- (a) TPN and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 64 | S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN and current carrying capacity 63 Amps in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 65 | S&F in repairs of MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA complete all as specified and directed. |
| 66 | S&F in repair SPN sheet metal enclosure with MCB 32 amps rated 240 volts with two pin and earth plug and socket complete all as specified and directed. |
| 67 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I) including taking out old existing earthing complete all as directed. Please Enable Macros to View BoQ information |