| 1 | SH I - Fire Fighting System ( i/c Fire Hydrant & Sprinkler System) - Item No: 1.01 & 1.02 |
| 2 | Facility Management Services for Fire Fighting System consist of Fire Hydrant & Sprinkler Systems along with associated installations as per inventory mentioned in Annexure-A1, i/c monitoring, operation and carrying out maintenance activities as per Annexure B1 to ensure the uninterrupted serviceability of entire system on round the clock basis by deploying minimum manpower as per Annexure - M i/c maintaining registers/ records etc., as per the special conditions and specifications etc., as required. |
| 3 | FIRST YEAR |
| 4 | SECOND YEAR |
| 5 | SUB HEAD: II (ARC Works- to carry out the works, Separate manpower should be deputed as and when required basis other than manpower mentioned in SH:I ) |
| 6 | Dismantling of existing split case/ radially split case type Centrifugal pump sets of following make/ models for necessary overhauling/ repairing i/c supply and replacement of both side bearings, mechanical seal, petty materials like stud bolts, gland packing, gasket, rubber bush for coupling etc. Cleaning and Greasing of bearings, reassembling, realignment of the pump with motor, testing, commissioning and painting etc. complete as required. |
| 7 | Kirloskar 85HP to 100 HP (Main Pump) |
| 8 | 171 cum/hr, Horizontal split case type, Make: Kirloskar Brothers/Mather & Platt make (Location: Cargo Fire Pump House) |
| 9 | Kirloskar 60HP to 95 HP (Diesel Pump) |
| 10 | 171 cum/hr, Horizontal split case type, Make: Kirloskar Brothers/Mather & Platt make (Location: Cargo Fire Pump House) |
| 11 | Kirloskar/Mather-platt 15HP (Jockey Pump) |
| 12 | 10.8 cum/hr, Horizontal split case type, Make: Kirloskar Brothers/Mather & Platt make (Location: Cargo Fire Pump House) |
| 13 | 1.5 HP (Dewatering) |
| 14 | Dismantling of following valves from the existing fire fighting water pipe line, Complete removal of scale deposits by acid dipping, scrapping and overhauling, replacement of packings, nut & bolts and gaskets etc. as required & reinstalling the same in its original postion i/c. testing and commissioing complete as required. |
| 15 | 10\\" and 12\\" Gate/Non Return/Ball/Foot valves |
| 16 | 6\\" and 8\\" Gate/Non Return /Foot valves |
| 17 | 2\\" to 4\\" Gate/Non Return/Foot valves |
| 18 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including dismantling of damaged Ms Heavy class pipes, Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 19 | 25 mm ( IS:1239, Heavy class) |
| 20 | 32 mm ( IS:1239, Heavy class) |
| 21 | 40 mm ( IS:1239, Heavy class) |
| 22 | 80mm ( IS:1239, Heavy class) |
| 23 | 100mm ( IS:1239, Heavy class) |
| 24 | 150mm ( IS:1239, Heavy class) |
| 25 | 200mm (6.35 mm Thick) |
| 26 | 250mm (6.35 mm Thick) |
| 27 | SUB HEAD: III (ARC Works- to carry out the works, Separate manpower should be deputed as and when required basis other than manpower mentioned in SH:I ) |
| 28 | Providing and fixing the following size of lever operated butterfly valves of approved make including dismantling the existing damaged one, replacement of the gasket, nut, bolts etc. as required. |
| 29 | 80mm dia (PN 16 Rated) |
| 30 | 100mm dia (PN 16 Rated) |
| 31 | 150mm dia (PN 16 Rated) |
| 32 | 200 mm dia (PN 16 Rated) |
| 33 | 250 mm dia (PN 16 Rated) |
| 34 | Providing and fixing the following size of Non return valves/ check Valve/ Gate valves of approved make including dismantling the existing damaged one , replacement of the gasket, nut, bolts etc. as required. |
| 35 | 100 mm Non return valve |
| 36 | 150 mm Non return valve |
| 37 | Replacement of faulty 1.5 Mtr length sprinkler flexible hose drops from false ceiling in the system, along with all required connectors, threading, coupler etc., complete as required. |
| 38 | Providing one welder and one Khalasi along with Electric welding/ gas cutting machine and welding rods/ Oxygen Acetlyne gas for carrrying out leak arresting/ welding of fire fighting lines or other welding works during any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency work as and when required. |
| 39 | Replacement of following suitable spare parts in hydrant delivery/ Landing valves(Single/ Double head), First aid Hose reel drums, other related accessories and valves in Fire hydrant and sprinkler system (as and when required basis). |
| 40 | Coupling washer |
| 41 | Seating washer |
| 42 | Gasket of suitable thickness |
| 43 | 12mm dia, 3\\" long bolts & Nuts |
| 44 | Rubber hose 20mm x 30 Mtr. Suitable for First aid Hose reel drum |
| 45 | O ring seal inside First aid Hose reel drum |
| 46 | 25mm forged brass Ball Valve |
| 47 | Brass Shutoff Nozzle with 1/2\\" ball valve |
| 48 | 20/25 mm GI clamps for rubber hose |
| 49 | 25mm GM Air release valve (Screwed type) |
| 50 | Providing and Fixing of 100mm dia Pressure gauges, 0-200PSI, H. Guru make or as per the approved make, specifications etc., complete as required. |
| 51 | Providing and fixing of pressure switch suitable for the existing system with a pressure range of 1 to 10 Bar etc., complete as required. |
| 52 | Dismantling of burnt out Induction motor from the system, including removal of burnt out stator winding and thorough cleaning of stator slots. Rewinding the stator with Class 'F' polyester coated super enameled copper wire and insulating materials i/c. baking, varnishing, finishing and refixing the stator in the motor frame & re-installation in Fire pump room including transportation to and fro from Pump room etc complete as required. |
| 53 | 100HP |
| 54 | 15 HP |
| 55 | 1.5 HP |
| 56 | Painting (two or more coats) with Synthetic enamel paint of approved shade and colour over one coat of red oxide primer over pipe lines including cleaning/ scrapping and marking the existing indications/numbers with white paint/sticker etc., complete as required. |
| 57 | Providing & fixing of MS fire hose box with nut and bolt as per standard etc. complete as required. (Approved makes : Minimax, Newage & Safex) |
| 58 | Supply and replacement of SS holding lugs with nut and bolt etc. complete as required. (Approved makes : Minimax, Newage & Safex) |
| 59 | Providing & fixing of female coupling with nut and bolt etc. complete as required. (Approved makes : Minimax,Newage & Safex) |
| 60 | Providing & fixing of MS wheel with nut and bolt with suitable as complete as required. (Approved makes : Minimax, Newage & Safex) |
| 61 | Providing & fixing MS trim kit and gong bell for alarm valve 150 NB with nut and bolt etc. complete as required. (Approved makes : Minimax, Newage & Safex) |
| 62 | Supply and fixing of ball valve etc., complete as required. (Approved makes : Zoloto, Sant & Audco) |
| 63 | 15mm ball valve |
| 64 | 50 mm ball valve |
| 65 | Providing and fixing of pressure gauge needle valve set with suitable existing pipe etc. complete as required. (Approved makes : Minimax, Newage & Safex) |
| 66 | Providing & fixing of 63 mm SS hose reel nozzle in the existing First aid hoze reel with suitable nut and bolt etc. complete as required. Approved makes : Minimax, Newage & Safex |
| 67 | Providing & fixing of 25 mm PVC hose reel SS nozzle with nut and bolt/ calmps etc. complete as required. (Approved makes: Minimax, Newage & Safex) |
| 68 | Providing & fixing of hydrant valve PVC cap, with nuts and screws etc. complete as required. |
| 69 | Supply and Fixing of Lead acid battery 12V 180 AH(Make:Exide) etc. including dismantling of exhausted batteries & shifting to the AAICLAS Stores etc complete as required. |
| 70 | Providing and fixing of 1\\" SS ball valve heavy class type etc. complete as required. (Approved makes : Zoloto,Sant & Audco) |
| 71 | Providing & fixing of MS key and SS branch with washers etc with complete as required .(Approved makes : Zoloto,sant & Audco) |
| 72 | Providing & fixing of suitable glass for Fire hydrant box door with screws for fire hydrant box etc. complete as required. |
| 73 | Providing and fixing of fire fighting PVC hose with nut in fire box each length of 15 meters with suitable couplings etc, complete as required. (Approved makes: Minimax, Newage & Safex) |
| 74 | Providing & fixing of Nipple for sprinkler drainage drain line with complete as required. |
| 75 | Supply of distilled water etc. complete as required. |
| 76 | Supply and fixing of 25mm ball valve with complete as required |
| 77 | Providing and fixing of hose reel drum set with hose 20mm x 30 mtr, hose reel nozzle with nut, bolt, clamp etc. complete as required. (Approved makes: Minimax,Newage & Safex) |
| 78 | Providing and fixing of Double headed landing hydrant valve with nut, bolt, washer, gaskets etc., complete as required.. (Approved makes: Minimax,Newage & Safex) |
| 79 | Providing and fixing of single headed fire hydrant landing valve with suitable bolt nuts and gaskets, etc., complete as required. (Approved makes : Minimax, Newage & Safex) |
| 80 | Numbering of Fire hydrant box/Fire hydrant landing pipe with double coated Red enamel paint with numbering in white paint of suitable size etc. complete as required. |
| 81 | Providing and fixing of Sprinkler bulb with washer, gaskets, nipple etc., complete as required. |
| 82 | SH IV : Fire Alarm system (i/c VESDA & Beam Detector)- Item No: 37.02 & 37.03 |
| 83 | Facility Management Services for Fire Alarm System consist of VESDA & Beam Detector along with associated installations as per inventory mentioned in Annexure-A2, i/c monitoring, operation and carrying out maintenance activities as per Annexure B2 to ensure the unintrupted serviceability of entire system on round the clock basis by deploying minimum manpower as per Annexure - C including maintaining registers/ records etc., as per the special conditions and specifications etc., as required. |
| 84 | FIRST YEAR |
| 85 | SECOND YEAR |
| 86 | Providing mobile communication facility at two locations (02 mobile) with minimum monthly topup of Rs. 300/- for each mobiles etc., complete as required . |
| 87 | FIRST YEAR |
| 88 | SECOND YEAR |
| 89 | SUB HEAD: V - PROVIDING SPARES FOR FAS ON AS AND WHEN REQUIRED BASIS. |
| 90 | Providing & fixing of Single Input Module complete as required.SIGA-CT1. (Make: Honeywell/EST or equivalent from list of approved make) |
| 91 | Providing & fixing of Detector Base - Standard complete as required. SIGA-SB. (Make: Honeywell/EST or equivalent from list of approved make) |
| 92 | Providing & fixing of Intelligent Fixed Temperature Heat Detector - 135F complete as required. XLS-HFS. (Make: Honeywell/EST or equivalent from list of approved make) |
| 93 | Providing & fixing of Isolator Module complete as required. XLS-IM. (Make: Honeywell/EST or equivalent from list of approved make) |
| 94 | Providing & fixing of Intelligent Photoelectric Smoke Detector with base complete as required. XLS-PS. (Make: Honeywell/EST or equivalent from list of approved make) |
| 95 | Providing & fixing of Control relay module complete as required. SIGA - CR. (Make: Honeywell/EST or equivalent from list of approved make) |
| 96 | Providing & fixing of Manual pull station complete as required. (Make: Honeywell/EST or equivalent from list of approved make) |
| 97 | Providing of Edwards Beam Detector, Model: EC-50RU |
| 98 | Providing of Network communication board (3-RS 485B) complete as required. Make: Honeywell/EST or equivalent from list of approved make |
| 99 | Providing & Fixing of RS232 communication board (3-RS 232) complete as required. Make: Honeywell/EST or equivalent from list of approved make |
| 100 | Providing & Fixing of LCD operator interface (3-LCD) complete as required. (Make: Honeywell/EST) |
| 101 | Providing & Fixing of Dual Signature Driver Controller (3-DSDC1) complete as required. (Make: Honeywell/EST) |
| 102 | Providing & Fixing of Booster power supply - 7 Amps complete as required. 3-PPS/M-230. Make: Honeywell/EST |
| 103 | Providing & Fixing of CPU (3-CPU3) complete as required. (Make: Honeywell/EST) |
| 104 | Providing & fixing of EST Mimic Repeater control card, complete as required. (Model: 3-EVDVRA) |
| 105 | Providing & fixing of EST Mimic Repeater Power Supply Card, complete as required. (Model: 3-EVPWR) |
| 106 | Providing & fixing of EST Mimic Repeater card, complete as required. ( Model: 3-ANNCPU3) |
| 107 | Providing & fixing of 24 watts Wall mounting speaker, complete as required. (Make: Bosch, Model: LBD 3921/00) |
| 108 | Providing & fixing of 450 - 600 W Booster power Amplifier with 3U height 21'' case for rack mounting LED display on front panel complete as required. (approved Make: Bosch), Model: LBB 1938/00 |
| 109 | Providing & fixing of Plena voice alarm Master controller, complete as required. (Model: LBB 1900, (Make : BOSCH)) |
| 110 | Providing & fixing of voice alarm system with plena voice alarm router having 6 zones complete as required. (Make: Bosch, Model: LBB 1992/00.) |
| 111 | Providing & Fixing of 12V, 65 AH, SMF battery complete as required.( Make: Exide) |
| 112 | Supply,Installation, Testing and Commissioning of VESDA complete as required. Make: VLP 250 Xtralis or equivalent from list of approved make |
| 113 | Supply of 2 core, 1.5 Sq.mm FRLS Copper conductor overall PVC sheathed GI wire Braided (flexible Armoured) FRLS grade cable etc. complete as required. (Approved make : Polycab or equivalent from list of approved make) |
| 114 | Laying of one number 2 core 1.5 Sq.mm Copper conductor overall PVC sheathed GI wire Braided ( flexible armoured) FRLS grade cable on surface for fire alarm circuit etc., complete as required. |
| 115 | Providing & Fixing of Pla relay complete as required (PLA MPC-2C-24D-5A-L) |
| 116 | Providing & Fixing of power supply for Pla relay complete as required. (230/24v Dc). (Approved makes : Seimens, L&T & Areva) |
| 117 | Supply of Solo A5 -001 Smoke Detector Tester 250 ml etc complete as required. |
| 118 | Supply of Solo A10S -001 HFC Free Smoke Dedector Tester 250 ml etc as required. |
| 119 | Supply of Smoke Detector Testing Kit Aerosol Dispenser and Telescopic Access Poles (6m Maximum Reach) |
| 120 | Supply and fixing of Printed Stickers for recording of recharging / maintenace activities of fire extinguishers etc as per direction of EIC. |
| 121 | Supply and fixing of conventional 2-zone panel -1 no, conventional smoke detector-02 nos, Hooter-1 no, MCP-2 nos complete as required |
| 122 | Supply and fixing of SIGA CC1 complete as required |
| 123 | Supply and fixing of EST strobe with flasher SIGA -G1AVRF/G1RF-HDVM complete as required |
| 124 | SUB HEAD:VI- (ARC for Fire Extinguishers and its associated Spares on as and when required basis.) |
| 125 | Replacement of following CO₂ Type FIRE EXTINGUISHER and SPARES |
| 126 | 4.5 kg CO₂ type Fire Extinguisher |
| 127 | 6 kg DCP type fire extinguisher |
| 128 | 9 kg DCP type fire extinguisher |
| 129 | CO₂ Horn for 4.5 kgs |
| 130 | CO₂ Handle Type Horn for 4.5 kg. |
| 131 | CO₂ M.S. Connecting Pipe for CO₂ Hose. |
| 132 | CO₂ Connecting PVC Handle included with rubber handle grip |
| 133 | CO₂ Plastic Lock ring.(15 Pieces) |
| 134 | CO₂ M.S.Lock Pin. |
| 135 | CO₂ Wall Mounting Bracket. |
| 136 | CO₂ 6.8 kg trolley with wheel complete. |
| 137 | CO₂ -2 Meter, Hose with Fitting. (Only Hose). |
| 138 | CO₂ Aluminum Wheel (Open Close) |
| 139 | CO₂ Brass Valves. (ISI Mark) |
| 140 | Replacement of following A.B.C. Type FIRE EXTINGUISHER SPARES |
| 141 | A. B. C. 06 kg. Hose with Fitting. |
| 142 | A. B. C. 09 Kg. Hose with Fitting. |
| 143 | A. B. C. Hose Pipe for 9 Ltr foam |
| 144 | A. B. C. Hose pipe for 50 Ltr foam |
| 145 | A. B. C. Foam additive for 50 HR foam extinguisher |
| 146 | A. B. C. Gas Cartridge 300 |
| 147 | A. B. C. Tralley Water & Foam |
| 148 | A. B. C. MS Pipe for Diptube (For 50 Ltr water & Foam) |
| 149 | A. B. C. Syphone Tube holder (For 50 Ltr water & Foam) |
| 150 | A. B. C. Elbow (For 50 Ltr water & Foam) |
| 151 | A. B. C. Wheel Fixed - (For 50 ltr Water & Foam) |
| 152 | A. B. C. Breather Valve for MS 50 Ltr Water & Foam |
| 153 | A. B. C. Cap with cartridge holder for 50 Ltr water & Foam |
| 154 | A. B. C. Hose Pipe for 50 Ltr water & foam - 3 Mtr |
| 155 | A. B. C. Ring Pressure release valve |
| 156 | SH-VII :AMC of Kirloskar make Diesel Engine |
| 157 | Inspection and service contract for kirloskar make Diesel Engines located at fire fighting pump rooms of cargo Ph-III as per Manufacturer's standard Instruction/ catalogues Practices as required.Engine Model: 6R1080Engine Sl.No: 6H-2203.16/ 1000005 at Cargo Ph-III |
| 158 | SH-VIII: B Check |
| 159 | Kirloskar Care Super Genuine Oil 20 Liters Can |
| 160 | SPIN ON LUBE OIL FILTER |
| 161 | FUEL FILTER KIT 1.1 LTR |
| 162 | Freight Charges Please Enable Macros to View BoQ information |