| 1 | Item Rate BoQ 82555/E8 BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE JAIPUR Name of Work: CERTAIN B/R REPAIRS INCLUDING ROOF TREATMENT TO OTM ACCN / MD ACCN IN SOUTHERN SECTOR AND REPAIR / MAINT OF CERTAIN ROOF TREATMENT, SUNKEN, FLOORING, TILING, PLASTERING, PLINTH PROTECTION & WATER SUPPLY / SANITARY FITTINGS ETC UNDER AGE B/R-I & AGE B/R-II AT MIL STN KOTA CA NO: CWE/KOTA- OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # SNo Item Description Item Code / Make Qty Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figure Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes Rate in Words Total Amount |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, such as sunken floor, roof padding etc complete all as specified and directed. |
| 3 | Taking down existing roof treatment of any type like APP membrane /felt etc including primer of any type over lime concrete/PCC padding/ roof concrete surfaces etc & cleaning of surfaces by brooming, watering etc. The material will be removed by the contractor outside MD land complete all as specified and directed. |
| 4 | M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed. |
| 5 | M&L for Cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in roof padding, kerbs, rounded or chamfered on edges complete all as specified and directed. |
| 6 | M&L for 15 mm thick rendering on fair faces of RCC roof slab in CM 1:3 duly mixed with liquid water proofing compound, finishing surfaces even and smooth without using extra cement, complete all as specified and directed.NOTE- Supply only water proofing liquid shall be measured and paid separately. |
| 7 | S&F for APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm , black finish reinforced with non-woven polyester matt, with a thermo fusible finish laid over compatible bitumen primer at the rate of 0.40 Kg/Sqm torching overlaps with a propane or butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instructions complete all as specified and directed.Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and there after surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied @1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm.(ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing.(iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) ln case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymericmembrane inserted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate. |
| 8 | M & L for PCC 1:5:10 type E-2, using 40 mm graded stone aggregate as in sunken floor mass-concrete complete all as specified and directed. |
| 9 | M & L for WPT in sunken floors as described here under:- Sunken floor and sides up to finished floor level shall be plastered with 15 mm thick cement plaster in CM 1:4 mixed with water proofing liquid @ 150 ml per bag of cement . (ii) Preparing plastered surfaces and providing APP polymeric water proofing membrane , minimum 3 mm thick and weighing not less than 3.0 kg/ sqm , black finish reinforced with non-woven polyster matt, with a thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm torching overlaps with a propane or a butane gas torch , with a over lap of 75mm at the sides and 100mm at the ends sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instructions including preparation of surface by removing the existing treatment, complete all as specified and directed Note :- (i) Polymeric membrane shall be laid in sunken floor and on sides up to finished floor level. (ii) The waterproofing treatment shall be got carried out by the manufacturer or their authorised applicators. (iii) Above aspects are deemed to be included in quoted rate. (iv) Supply only water proofing liquid shall be measured and paid separately |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises outside MOD Land complete all as specified and directed. |
| 11 | M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) for level course complete all as specified and directed. |
| 12 | S&F coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 for receiving floor finish complete all as specified and directed. |
| 13 | M&L glazed coloured digital ceramic tiles of size (450mmx300mm) x 6 to 7 mm thick, on vertical surfaces, such as dado, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including rendering 10mm thick in CM 1:4 as backing coat to receive dado finish complete all as specified and directed. |
| 14 | M&L for vitrified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 for receiving floor finish complete all as specified and directed. |
| 15 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid dry and pointed etc. complete all as specified and directed. |
| 16 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 17 | M&L for 18-20 mm thick Green marble work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 18 | Taking down cement plaster on brick or stone wall incl raking not joints scrubbing down with water complete all as specified and directed. |
| 19 | M&L for rendering 15mm thick in CM 1:6 on stone or concrete surfaces finished even & smooth to internal surfaces on wall complete all as specified and directed. |
| 20 | M&L for preparation of new surfaces of wall care putty of walls and applying two coats of oil bound distemper paint by roller and applying 3mm thick wall care putty on wall all as specified and directed. |
| 21 | M&L preparation of newly plastered surfaces & applying three coat of white wash on wall complete complete all as specified and directed. |
| 22 | M&L for rendering 15mm thick in CM 1:4 mixed with water proofing compound on stone or concrete surfaces finished even & smooth to external surfaces on wall complete all as specified and directed.Note:- Water proofing compound shall be measured and paid separately. |
| 23 | Supply only waterproofing compound complete all as specified and directed. |
| 24 | M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over primer complete all as specified as mentioned in note of the item and directed by Engineer-in-Charge.Note :- Colour scheme of cement base paint passed by GE.Steps to be followed for cement base paint(a) curing the newly plastered surface of wall by spray gun(b) Applying one coat of primer(c) applying one coat of cement base paint(d) curing of surface by spray gun(e) Applying second coat of cement base paint After that curing of surface by spray gun. |
| 25 | M&L for rendering 10mm thick in CM 1:3 on brick or concrete surfaces finished even and smooth as in ceiling complete all as specified and directed. |
| 26 | M&L preparation of newly plastered surfaces & applying three coat of white wash on ceilings complete all as specified and directed. |
| 27 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thick (below or above GL) complete all as directed by EIC. |
| 28 | M&L for 75mm thick PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed. |
| 29 | Taking down 15mm bore steel tubing & connection including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 30 | Taking down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 31 | M&L for 15mm bore medium grade concealed GI tubing with all fittings fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 32 | M&L for 20mm bore medium grade GI tubing with all fittings fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 33 | S&F in repair brass chromium plated shower rose 125mm size fixed complete all as specified and as directed.Make- CERA cat part No F7010212AB/ Hindware cat part no F 160145/ parryware cat part no T9809A1 or equivalent makes specified in PS. |
| 34 | S&F in repairs Bib taps 15mm dia, chromium plated, long body with CP flange complete all as specified and as directed.Make- CERA cat part No F2013151/Parryware cat part No G4880A1/Hindware cat Part No F78006 or equivalent makes specified in PS. |
| 35 | S&F in repair 15mm bore angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.Make- Hindware cat part no F650043/cera cat part no F1019201/Parryware cat part no T1372A1 or equivalent makes specified in PS. |
| 36 | S&F in repairs 32mm high density polythylene pipes (HDPE) of pressure rating 6kg/cum fixed complete to walls ceiling or in floors etc complete all as specified and directed. |
| 37 | S&F in repair PVC connection pipe of 15 mm bore 600mm long with brass connector complete all as specified and directed. |
| 38 | S&F in repair vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, including making good to floor all as per specified and directed. Make- CERA Cat part No S3010109 /Parryware cat part no C0117CS1C / hindware cat part no 20143 or equivalent makes specified in PS. |
| 39 | S&F in repair Vitreous China wash down water closet pan(pedestal pattern) white (squatting pan & trap including 'P' or 'S' trap connection to drain (or out going pipe and to flushing pipe anti shyfonic pipe etc completely fixed complete all as specified and directed.Make- CERA cat par No S1059101/Parryware cat part no C02521C/Hindware cat part no 519010 or equivalent makes specified in PS. |
| 40 | S&F in repair plastic water closet seat , black, closed pattern with flat bottom & cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 41 | S&F low level flushing system plastic valveless syphonic action type white with inlet ball valve float chain and ball (of capacity 10 ltrs ISI marked inck 32mm PVC flush pipe as in repairs complete all as specified and directed. Make- CERA Cat No. B1010112/ Parryware cat part no E82971C/ Hindware cat part No. 511209 or equivalent makes specified in PS. |
| 42 | S&F in repairs towel rail of CP fixed with and including CP brass screws and wooden plastic cleats (min wt 90 gms) complete all as specified and directed.Make- Cera cat part No F5014104CH /Parryware cat part no T6901A1/ Hindware cat par no F880005 or equivalent makes specified in PS. |
| 43 | S&F in repair for vitreous china wash basin white size 510x405x155 mm excluding taps but including 32 mm dia CP waste fitting and brackets complete all as specified and directed.Make- CERA Cat No S2040212/Parryware cat part no C04711C/ Hindware cat par no 10124 or equivalent makes specified in PS. |
| 44 | S&F in repairs pillar taps, 15mm dia, long body/swan neck, fancy type suitable for fixing to wash basin screwed for iron pipe and fixed with necessary fittings complete all as specified and directed.Make- CERA Cat Part No F2002101 / Parryware cat part no G5201A1/ Hindware cat par no F690001 or equivalent makes specified in PS. |
| 45 | S&F in repair 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed with necessary fittings complete all as specified and directed.Make- CERA Cat part No 2002401/Parryware cat part no G5216A1/ Hindware cat part no F690022 or equivalent makes specified in PS. |
| 46 | S&F in repairs Soap dish any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. Make-CERA Cat Part No F5013106CH/ Parryware cat part no T6003A1/ Hindware cat part no F 880011 or equivalent makes specified in PS. |
| 47 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making Connections and fixed in position complete all as specified and directed. Make- CERA Model-F 8030101CH (ABS)/ Parryware cat part no-E8342A1/Hindware cat par no F160242 or equivalent makes specified in PS. |
| 48 | S&F in repairs stainless steel Grating doom in square shape with or without hole in 100 mm size (Minimum Each weight 25 gms) complete all as specified and directed |
| 49 | S&F in repair bevelled edge mirror 600x450mm size of selected quality on 6mm thick AC sheet or 6mm thick AC sheet or 6mm thick commercial plywood fixed to wdn plugs with CP Brass screws & cup washers complete all as specified and directed. |
| 50 | S&F Rotational moulded three layered white colour polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 Itrs complete including dismantling water tanks complete all as specified and directed. |
| 51 | S&F Rotational moulded three layered white colour polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 Itrs complete including dismantling water tanks complete all as specified and directed. |
| 52 | S & F in repair for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, Bore dia of pipe in 20 mm, etc complete all as specified and directed. |
| 53 | S & F in repair for Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms), Bore dia of pipe in 20 mm, etc complete all as specified and directed. |
| 54 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints , laid in trenches / floors or fixed to walls complete all as specified and directed. |
| 55 | Description all as per Item No 53.00 above but 75 mm bore complete all as specified and directed. |
| 56 | S&F in repair 110 mm bore PVC (SWR) bends complete all as specified and directed. |
| 57 | S&F in repair 75 mm bore PVC (SWR) bends complete all as specified and directed. |
| 58 | M&L for 30mm to 50mm thick sand stone slabs for roofing set and jointed in Cement mortar 1:4 over joists, etc., complete all as specified and directed. |
| 59 | M&L for Stone slab 25 mm to 35 mm thick dressed true and square, in one length not less than 60cm and n. exc 120cm in copings, window cills, chajjas, sunshades, etc., punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges rounded or chamfered as directed, set, jointed and pointed in 1:4 cement mortar complete all as specified and directed. |
| 60 | Disconnecting existing PVC over head tank cap exc 250ltr but n exc 500 ltrs setting aside (or lowering if required) for roof treatment below tank area and reconnecting/re-fixing in same position complete all as specified and directed.Note :- Before disconnecting if monkey case installed on tank remove safely without damage and reinstall same after refixing the tank, if any damage found contractor shall repair without any cost. |
| 61 | M&L for Cleaning and removing all scale and dirt from tanks cap exc 250 ltr but n exc 500 ltrs, etc,and from mouths of circulating pipes, etc. complete all as specified and directed. |
| 62 | Disconnecting existing PVC over head tank cap exc 500 ltrs but n exc 1000 ltrs setting aside (or lowering if required) for roof treatment below tank area and reconnecting/re-fixing in same position complete all as specified and directed.Note :- Before disconnecting if monkey case installed on tank remove safely without damage and reinstall same after refixing the tank, if any damage found contractor should be repair without any cost. |
| 63 | M&L for Cleaning and removing all scale and dirt from tanks cap exc 500 ltr but n exc 1000 ltrs, etc,and from mouths of circulating pipes, etc. complete all as specified and directed. |
| 64 | Fixing only 20 mm dia steel water tubing, galvanized, medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. |
| 65 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 66 | S&F Framed work as in doors or gates of angle or water casing or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing complete FE 290 Gde E-165 complete all as specified and directed. |
| 67 | S&F in renewal of wire netting of galvanised steel wire 1.40 mm dia fixed on angle with welding, size of mesh 25 mm, complete all as specified and directed. |
| 68 | M&L for Cutting and grubbing of bushes grass and tree and its roots complete surrounding drain out nala on roof top, parapet wall, over head tank area, wall pipe etc and making good of disturbed surface by PCC 1:2:4/stone/brick masonary and finish the surface of wall and removing the waste material to a distance exc 50m and n exc 500m from the site complete all as specified and directed. |
| 69 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 70 | M & L for preparation of old or previously treated steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 71 | Supply & applying fiber reinforced UV resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester/ glass fibres after scrapping and properly cleaning the surface to remove loose particles with wire brushes , over a coat of primer as per manufacturers instruction complete all as specified and directed. |
| 72 | M &L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. |
| 73 | M & L for PCC (1:2:4) type B-0 using 12.5 mm stone Aggregate as in coping including necessary form work complete all as specified and directed. |
| 74 | Supply only Integral water proofing Liquid complete all as specified and directed. |
| 75 | Schedule of Credit Total in Figures 0.0 0.0 -46271.0 Quoted Rate in Figures Select 0.0 0.0 Zero Only 0.0 Quoted Rate in Words INR Minus Forty Six Thousand Two Hundred & Seventy One Only Please Enable Macros to View BoQ information |