| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work:Repair/ maint of hangars and other OTM Accn including roof, false ceiling, tilling, aluminium/ wooden joineries & other connected works in Tech Area at AF Stn Gorakhpur. Contract No.: GE(AF)/GKP/E-19 OF 2026-27 File No.9457/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed |
| 3 | Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm. |
| 4 | Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed. |
| 5 | M&L for sand cushioning to U/G cable in layers of 23 cm thick( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed.Note :- Only Puned down volume shall be measured. |
| 6 | Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed. |
| 7 | Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed |
| 8 | Taking out unserviceable LT U/G cable from trenches of size 6 Sqmm to 120 Sqmm 2/3.5/4 core complete all as specified and as directed. |
| 9 | Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 4 core |
| 10 | All as per item No-8 above but of size 16 sqmm 4 core. |
| 11 | All as per item No-8 above but of size 25 sqmm 4 core. |
| 12 | All as per item No-8 above but of size 35 sqmm 3.5core. |
| 13 | All as per item No-8 above but of size 50 sqmm 3.5core. |
| 14 | All as per item No-8 above but of size 70 sqmm 3.5core. |
| 15 | All as per item No-8 above but of size 95 sqmm 3.5core. |
| 16 | All as per item No-8 above but of size 120 sqmm 3.5core. |
| 17 | M&L for Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 100 mm bore(dia) for passing UG cable, complete all as specified and as directed. Note : - GI Pipe laid will be measured and paid separately under respective item |
| 18 | S&F in replacement of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified . |
| 19 | S&F in replacement of 25 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and directed. |
| 20 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 32x6 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as specified and directed. |
| 21 | Dismantling existing unserviceable feeder pillar box including disconnection from different sites complete all as specified and directed. |
| 22 | Fabrication, supply, installation, testing and commissioning in replacement of outdoor type feeder pillar box floor mounted made out from 3.15 mm thick MS sheet ( CPRI type tested) with canopy type roof, front operated, one part hinged doors with locking arrangement comprising of Aluminium bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter with heat strinkable PVC sleeving having RYB-B colour code drilling holes for connection of incoming and outgoing cable, complete powder coated painting, testing and installation on PCC/brick foundation, connection of cable with suitable aluminium lugs all as specified and directed. |
| 23 | M&L for cleaning of MES electric supply installations/campus/complaint cell area by surface dressing or trimming of natural ground to remove small inequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete for the various sub stations.Note:- Measurements shall be taken once in entire period of contract. |
| 24 | S & F in replacement MCCB 630 Amps, 4 pole, 415 volts, 50 Hz 50 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed |
| 25 | S & F in replacement MCCB 400 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed |
| 26 | S & F in replacement MCCB 315 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed |
| 27 | S & F in replacement MCCB 250 Amps , 4 pole, 415 volts , 50 Hz , 25 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed |
| 28 | S & F in replacement MCCB 200 Amps , 4 pole, 415 volts , 50 Hz , 25 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed |
| 29 | S & F in replacement MCCB 160 Amps , 4 pole, 415 volts , 50 Hz , 25 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB all as specified and directed |
| 30 | M&L straight through joints( epoxy) for LT underground cable including joint kits suitable for aluminium conductor cable 3.5 core 6 sqmm to 240 sqmm all as specified and directed |
| 31 | M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 6 sqmm to 240 Sqmm (3.5/4C) all as specified and directed |
| 32 | M & L for preparing old painted surfaces by scraping and removing old paints,rust etc from steel tubular poles (above the planting depth and PCC coping of 9.0 Metre long pole) and Mild Steel cross arms, cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting ( 5 Nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc painted with one coat of aluminium paint including marking of pole No with black background and white lettering with all arrangement for ladder etc all as specified and directed . |
| 33 | Dismantling of old PCC/steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation, earth work as reqd & removing the same from site complete all as specified and as directed. |
| 34 | Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9 mtr long, complete all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.(b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work.(c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work.(d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.(e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Painting of coping shall be cement base paint complete all as directed.Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (f) only. All other connected work, shall be measured and paid on this account. |
| 35 | Disconnection and dismantling of existing serviceable under ground cable of size 6 Sqmm to 240 Sqmm 2/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed. |
| 36 | M&L for providing and laying coarse aggregate 40 mm nominal size, graded quality, for spreading in Transformer Yard / Sub Station area over prepared and cleared surface, including dressing, uniform spreading, levelling, compacting/settling to required profile and thickness and removal of surplus material, complete in all respects and all as specified |
| 37 | M&L for spraying of approved weed/grass killer chemical Paraquat Dichloride 24% SL Herbicide in Sub Station premises using manually operated spray equipment, including mixing with water in manufacturer’s recommended ratio, uniform application over designated area, cleaning after application and all associated labour, complete in all respects and directed by Engineer-in-Charge |
| 38 | Detecting of fault of LT UG cable (any place any length any type /size) with help of vehicle mounted cable fault locator including detecting exact location of cable fault and remove of cable for rectification. complete all as specified and as directed. |
| 39 | Supply, install, testing and commissioning of LT Cubicle panel of suitable size, outdoor type, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6mm angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts , springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz , 3 phase 4 wire system 1100 volts grade, coloured heat shrinkable sleaving, internal connection should be provided with aluminium strip of suitable size and necessary grouting/ foundation all as required at site and comprising following:-:- a) Ammeter, digital including selector switchb) CT of required capacity -03 No(c) Voltmeter Digital type including selector switch(d) Phase indicating lamps -03 Nose) Control wiring(f) Copper conductor wiring .G) BusBar strip made out of aluminium of 400 amps capacity mounted on insulators.h) MCCB 4 Pole 415 Volt 250 Amps Capacity, 36 KA - 01 Nos ( for incoming ) |
| 40 | M & L for taking down Street light fittings of any descriptions from any height after disconnecting electric connections and opening cover and checking of light fittings for serviceability and repaired as required and re-fixing the light fittings in existing position after repair and providing connections including replacement of defective/ unserviceable spares/ parts etc as required to make the fittings in smooth serviceable condition and testing complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts shall be measured and paid seperately as \\"supply only\\" (ii) Replacement of minor spares/ parts such as nuts, bolts & washer, worn out cables as per existing size etc shall deemed to be included in the unit quoted rate) |
| 41 | Supply only Driver suitable for LED street/ security light fittings 45 Watt upto 400 watt complete all as specified and directed. |
| 42 | Disconnecting and taking out old unserviceable light fitting’s bracket incl FI clamps of any description and in any position andS & F in repair Street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 43 | Disconnecting and taking out old existing unserviceable junction box and S & F in repairs IP rated junction box made of impact resistance polycarbonate & heat resistant materials of size 200x160x98mm mm, dust proof, water tight, light weight, acid resistant, corrotion proof insulated and shock proof, fire retardant, self extinguishing, helogen & silica free non toxic material, UV resistant with internally embedded gasket and fitted with required terminals alongwith complete all as specified and directed directed. |
| 44 | M & L for lowering down high mast light assembly from pole disconnecting UNSV highmast light fitting and again lifting up highmast light assembly carefully of any type/height after repair/replacement of highmast lights or submain wiring complete all as specified and directed.(NOTE: Highmast light fitting will be measured and paid saperately) |
| 45 | S&F(in repair) LED High mast light fitting of capacity 400 watt energy saving, environment friendly, long life, exclusive innovative die-cast aluminium IP66 flood light suitable for high lighting architectural façade and general purpose lighting (Highmast) complete with operating voltage 10 degree centigrade to 50 degree centigrade with operating voltage range 140 volt to 270 volt and serge protection upto 10KV with inbuilt SPD complete all as specified and directed. |
| 46 | Disconnecting and taking out old existing unserviceable flood light fitting of any description and supplying & Fixing, testing energy saving, die cast aluminium housing IP 65 protection,50 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps,nuts,bolts & washers all as per site requirement and as directed. |
| 47 | Disconnecting and taking out old existing unserviceable flood light fitting of any description and supplying & Fixing, testing energy saving, die cast aluminium housing IP 65 protection,120 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps,nuts,bolts & washers all as per site requirement and as directed. |
| 48 | Disconnecting and taking down old UNSV timer and Supplying and fixing Automatic Timer switch which switches ON/OFF the street lights based on LUX level of natural light ranges from less than 30 LUX and More Than 10 LUX of capacity 8 KW Three phase, 220V contactor rating 40A,incoming-outgoing MCB rating 40A having over voltage and under volttage protection all as specified and directed. complete all as specified and directed. |
| 49 | Supply and fix in repair Intergral LED Post-Top Luminaire 25 W Comprises housing with LEDs and driver. Glare-free and better uniformity and Heat resistant toughened glass with frame suitably gasketed for IP 65 Class I protection including all accessories, all as specified and directed. |
| 50 | S&F New LED Bollard light(Garden Light) 9 Watt,single phase,240 Volts with 9 watt LED lamp opal diffuser & aluminium reflector all as specified and directed. |
| 51 | S & F in repairs LED bulb 9 watt complete all as directed. |
| 52 | Disconnecting and taking out old existing unserviceable street light fitting of any description and Supply & fixing Street light fitting IP-66 powder coated pressure die cast aluminium housing with high power LED as lighting source with heat resistant toughtened glass 70 W LED with 10kv surge protection complete with all assessaries of capacity 70 watt all as specified and directed make :Philips/Bajaj/crompton or equivalent make approved by GE |
| 53 | Supply & fixing in replacement PVC insulated and sheathed unarmoured three core copper conductor cable 2.5 sqmm 1100 volt to be replaced in existing fittings complete all as specified and directed . Total in Figures 23 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |