| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of work : Repair/Replacement of UNSV wiring at Old Mil Stn Kapurthala under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc; complete all as directed. |
| 3 | M&L in repair for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor (FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC casing caping with all accessories including 1.5 sqmm copper multistrand conductor (FRLS) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box, complete all as specified and as directed. |
| 4 | One light point controlled by one, one way switch complete all as specified and as directed. |
| 5 | One fan point controlled by one, one way switch complete all as specified and as directed. |
| 6 | One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and as directed. |
| 7 | One socket outlet 3 Pin, 5 Amp on same boardcomplete all as specified and as directed. |
| 8 | One bell point controlled by one bell push complete all as specified and as directed. |
| 9 | One light point controlled by two, two way switch complete all as specified and as directed. |
| 10 | - ditto - all as per item No 2 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board complete all as specified and as directed. |
| 11 | - ditto - as per item No 2 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 3 pin 15 Amp switch socket combination on independent board complete all as specified and as directed. |
| 12 | M&L in repair for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor ( FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor (FRLS ) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed. |
| 13 | One light point controlled by one, one way switch complete all as specified and as directed. |
| 14 | One fan point controlled by one, one way switch complete all as specified and as directed. |
| 15 | One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and as directed. |
| 16 | One socket outlet 3 Pin, 5 Amp on same board complete all as specified and as directed.. |
| 17 | One bell point controlled by one bell push complete all as specified and as directed. |
| 18 | One light point controlled by one, two way switch complete all as specified and as directed. |
| 19 | - ditto - as per item No 5 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board complete all as specified and as directed. |
| 20 | - ditto - as per item No 5 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board complete all as specified and as directed.. |
| 21 | M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FRLS) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with white frame for Modular fittings of required size for 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed. |
| 22 | One light point controlled by one, one way switch complete all as specified and as directed. |
| 23 | One fan point controlled by one, one way switch complete all as specified and as directed. |
| 24 | One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and as directed. |
| 25 | One socket outlet 3 Pin, 5 Amp on same board complete all as specified and as directed. |
| 26 | One bell point controlled by one bell push complete all as specified and as directed. |
| 27 | One light point controlled by one, two way switch complete all as specified and as directed. |
| 28 | - ditto - as per item No 8 here in before but 2.5 Sqmm PVC insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board complete all as specified and as directed. |
| 29 | S&F in repair switch piano flush type single pole one way 6 Amp (ISI Marked) |
| 30 | S&F in repair switch piano flush type single pole two way 6 Amp (ISI Marked) complete all as specified and as directed. |
| 31 | S&F in repair switch piano flush type single pole one way 15 Amp (ISI Marked) complete all as specified and as directed. |
| 32 | S & F in repair bell push flush type 5 amp complete all as specified and as directed. |
| 33 | S&F in repair socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) complete all as specified and as directed. |
| 34 | S&F of socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) complete all as specified and as directed. |
| 35 | S&F of modular switch single pole one module 6- 10 Amp (ISI Marked) complete all as specified and as directed. |
| 36 | S&F of modular switch single pole one module 15 Amp (ISI Marked) complete all as specified and as directed. |
| 37 | S&F of modular socket out let 2 in 1, 3 pin 15 Amp 2 module (ISI Marked ) complete all as specified and as directed. |
| 38 | S&F of modular socket out let 2 in 1, 3 pin 5/6 Amp 2 module (ISI Marked ) complete all as specified and as directed. |
| 39 | S&F of modular fan regulator 1 module (ISI Marked) complete all as specified and as directed. |
| 40 | S&F in repair modular bell push switch one module complete all as specified and as directed. |
| 41 | S&F in repair modular switch 2 way 6A, 250 V AC 1 module complete all as specified and as directed. |
| 42 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked) |
| 43 | S&F in repair electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan complete all as specified and as directed. |
| 44 | S&F in repair buzzer/ding dong, A C , 230 volt single pole complete all as specified and as directed. |
| 45 | S&F in repair PVC/Polycarbonate lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type with back plate suitable for batten fittings complete all as specified and as directed. |
| 46 | Taking down Old unsv sub main and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper conductor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 4.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed.Note:- Two run of 6.00 Sqmm cable one run of 4.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) |
| 47 | Taking down Old unsv sub main and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper conductor, multi stranded cable of size 10.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed. Note:- Two run of 10.00 Sqmm cable one run of 6.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) |
| 48 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. |
| 49 | Taking down carefully ceiling fan of any size any description from existing location and carrying out cleaning & servicing including replacement unsv parts, painting with synthetic enamel paint by spraying, greasing and heat varnishing and refixing the same in same location/new location and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed. For the purpose of maintenance, each ceiling fan shall be treated as an assembly of the following serviceable components ( Item number 31 to 35) :- The unserviceable parts shall be measured and paid as separately. |
| 50 | Rewinding of ceiling fan any size any description with same size wire and insulating material including replacement of suitable capacitor, ball bearing and other necessary reqd accessory for smooth functioning of fan complete all as specified and directed. |
| 51 | S&F in replacement motor as single Motor Unit Assembly consisting of single phase induction motor ( Including stator, rotor, shaft, bearings, and motor housing ) suitable for 50 - 125 watt Ceiling fan all as per sample kept in AGE E/M office. |
| 52 | S&F in replacement blade assembly (Including blades 3 nos , blade arms/brackets and fastening hardware)as per the suitability of a ceiling fan. all as per sample kept in AGE E/M office |
| 53 | S&F of electrical assembly (Including capacitor, internal wiring, terminal connectors, and associated electrical accessories such as regulator, if within scope) as per the suitability of ceiling fan all as per sample kept in AGE E/M office. |
| 54 | S&F of suspension and mounting assembly (Including down rod, shackle/hook, canopy, and supporting fixtures) suitable for ceiling fan complete all as specified and directed. |
| 55 | Taking down carefully exhaust fan of any size from existing location and carrying out cleaning & servicing including painting with synthetic enamel paint by spraying, greasing and heat varnishing and refixing the same in same location/new location and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed.For the purpose of maintenance, each Exhaust fan shall be treated as an assembly of the following serviceable components ( Item number 37 to 41) :- The unserviceable parts shall be measured and paid as separately. |
| 56 | Rewinding of exhaust fan any size any description with same size wire and insulating material including replacement of suitable capacitor, ball bearing and other necessary reqd accessory for smooth functioning of fan complete all as specified and directed. |
| 57 | S&F of motor unit assembly (Including stator, rotor, shaft, bearings, and motor housing of desired capacity and material. all as per sample kept in AGE E/M office |
| 58 | S&F of impeller/blade assembly (Including fan blades/propeller, hub, and fastening hardware), complete all as specified and directed. |
| 59 | S&F of casing and aounting assembly (Including outer frame, mounting brackets, louvers/shutters, and fixing arrangements). all as per sample kept in AGE E/M office |
| 60 | S&F of electrical assembly (Including capacitor, internal wiring, terminal connectors, and associated electrical accessories such as regulator/switch, if within scope. all as per sample kept in AGE E/M office |
| 61 | Taking down carefully geysers of capacity 25 Ltr from existing location and carrying out cleaning of inner tank with descaling compound repairing including changing of Old unsv components(excluding heating element thermostat), including painting with synthetic enamel paint by spraying, and re fixing the same in same location/new location. |
| 62 | M&L for geyser inner tank assembly including inner assembly , indicator, safety valve, multifunction valve, thermal switch, auto cut switch, gaskets, gasket, fasteners complete suitable for 25 litter including connecting electrical lead all as per sample kept in AGE E/M office |
| 63 | M&L for geyser outer body made out of metal / Abs , insulating material suitable for 25 Ltr capacity all as per sample kept in AGE E/M office |
| 64 | S&F in repair PVC flexible connecting pipe for cold/hot water 450mm ling with brass end plug complete all as specified and directed. |
| 65 | S&F in repair heating element 2000 watt with triangular/round base mounting suitable for 25 Ltr capacity complete all as specified and directed. |
| 66 | S&F in repair thermostat suitable for geyser of capacity 25 Ltr complete all as specified and directed. |
| 67 | S&F in repair fan capacitor 2.5 MFD complete all as specified and directed. |
| 68 | S&F in repair fan capacitor 4 MFD complete all as specified and directed. |
| 69 | S&F in repair LED batten tube light (4ft) for surface and pendant applications,18/ 20 watt, colour Temp 3000 K 5000 K complete all as specified and directed. |
| 70 | S&F in repair LED batten tube light (4ft) for surface and pendant applications, 36/ 40 watt, colour Temp 3000 K 5000 K complete all as specified and directed. |
| 71 | S&F in repair sleek roundrecessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination sleek surface 6watt, colour Temp 3000 K 5000 K complete all as specified and directed. |
| 72 | S&F in repair sleek square recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination sleek surface 6watt , colour Temp 3000 K 5000 K complete all as specified and directed. |
| 73 | S&F in repair sleek round recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination sleek surface 12watt, colour Temp 3000 K 5000 K complete all as specified and directed. |
| 74 | S&F in repair sleek square recessed mounted LED down light with white powder coated die cast housing and diffuser for low glare illumination 12 watt, Colour Temp 3000 K 5000 K complete all as specified and directed. |
| 75 | S&F in repairing in repair LED security light fitting 35 watt pressure die cast aluminium housing, heat resistant toughened glass with frame IP 66 protection complete all as specified and directed. Colour Temp 3000 K 5000 K. |
| 76 | S&Fing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Colour Temp 3000 K 5000 K |
| 77 | S&F in repair PVC insulated aluminium 6 Sqmm 2 core sheathed cable, complete all as specified and as directed. |
| 78 | S&F in repair plastic body exhaust fan 250 dia , rust proof body, dust protection shutter connecting lead suitable for toilet/bathroom all as specified and directed. |
| 79 | S&F in repair sheet metal enclosure for MCB double door single pole & neutral 4 way with 200 Amps rated bus bar complete all as specified and as directed. |
| 80 | S&F in repair sheet metal enclosure for MCB double door single pole & neutral 8 way with 200 Amps rated bus bar complete all as specified and as directed. |
| 81 | S&F in repair sheet metal enclosure for MCB double door single pole & neutral 12 way with 200 Amps rated bus bar complete all as specified and as directed. |
| 82 | S&F in repair sheet metal enclosure for MCB double door triple pole & neutral 4 way with 200 Amps rated bus bar complete all as specified and as directed. |
| 83 | S&F in repair sheet metal enclosure for MCB double door triple pole & neutral 6 way with 200 Amps rated bus bar complete all as specified and as directed. |
| 84 | S&F in repair sheet metal enclosure for MCB double door triple pole & neutral 8 way with 200 Amps rated bus bar complete all as specified and as directed. |
| 85 | S&F in repair sheet metal enclosure for MCB double door single pole & neutral 2 way with without bus bar all as specified and directed. |
| 86 | S&F in repair miniature circuit breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA suitable for lighting and other domestic loads Single pole 6 to 32 Amp, complete all as specified and as directed. |
| 87 | S&F in repair miniature circuit breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA suitable for lighting and other domestic loads Single pole & neutral 6 to 40 Amp, complete all as specified and as directed. |
| 88 | S&F in repair miniature circuit breaker (MCB) ‘B’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA suitable for lighting and other domestic loads triple pole & neutral 6 to 40 Amp, complete all as specified and as directed. |
| 89 | S&F in repair miniature circuit breaker (MCB) ‘C’ Curve (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA suitable for lighting and other domestic loads triple pole & neutral 63 Amp, complete all as specified and as directed. |
| 90 | S&F in repair TP&N vertical double door 4 way ,MCCB as incomer with bus bars, neutral links, blanking plates including MCB, complete all as specified and as directed. |
| 91 | S&F in repair MCCB 100 Amp , 415 volt 4 pole complete, complete all as specified and as directed. |
| 92 | S&F in repair modular switch 6 Amp 250 V AC one way one module as per suitability of Frame already existing on work site complete all as specified and as directed. |
| 93 | S&F in repair modular switch 16 Amp 250 V AC one way with indicator one module as per frame suitability already existing on work site complete all as specified and as directed. |
| 94 | S&F in repair modular socket, 6A - 2/3 pin combined 2 module as per frame suitability already existing on work site complete all as specified and as directed. |
| 95 | S&F in repair modular socket 6A/16A - 2/3 pin combined 2 module on work site complete all as specified and as directed. |
| 96 | S&F in repair modular fan regulator step type, 1- 2 module on work site complete all as specified and as directed. |
| 97 | S&F in repair in repair metal flush mounting box of 1/2 module complete all as specified and as directed. |
| 98 | S&F in repair in repair metal flush mounting box of 3 module complete all as specified and as directed. |
| 99 | S&F in repair in repair metal flush mounting box of 4 module complete all as specified and as directed |
| 100 | S&F in repair in repair metal flush mounting box of 6 module complete all as specified and as directed. |
| 101 | S&F in repair in repair metal flush mounting box of 8 module complete all as specified and as directed. |
| 102 | S&F in repair white cover plate with frame, 1 module complete all as specified and as directed. |
| 103 | S&F in repair white cover plate with frame, 2 module complete all as specified and as directed. |
| 104 | S&F in repair white cover plate with frame, 3 module complete all as specified and as directed |
| 105 | S&F in repair white cover plate with frame, 4 module complete all as specified and as directed. |
| 106 | S&F in repair white cover plate with frame, 6 module complete all as specified and as directed. |
| 107 | S&F in repair white cover plate with frame, 8 module complete all as specified and as directed. |
| 108 | S&F in repair PVC gang box for mounting switches 01 modulecomplete all as specified and as directed. |
| 109 | S&F in repair PVC gang box for mounting switches 02 modulecomplete all as specified and as directed. |
| 110 | S&F in repair PVC gang box for mounting switches 06 modulecomplete all as specified and as directed. |
| 111 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 2 way |
| 112 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 4 way |
| 113 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 6 way |
| 114 | S&F in repair LED bulk head fitting 10 watt highly cost effective compact, ultra low energy, modern design utility bulkhead suitable for indoor and outdoor applications with IP 65 protection complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076, complete all as specified and as directed. |
| 115 | M&L for repairing of unserviceable wiring of distribution board any type any capacity including adding new wire of same size same material, insulating properly bare joint, systematically arranging wiring using clamps , conduits, complete all as specified and as directed. |
| 116 | S&F of decorative garden light 10 watt suitable for withstanding outdoor weather and rain,dust tight, IP-65, complete all as specified and as directed. |
| 117 | S&F in repair LED batten tube light (2ft) for surface and pendant applications. 8-10 watt, complete all as specified and as directed. |
| 118 | S&F in repair MCB protected socket PVC plastic base model suitable for geyser and ACS complete unit comprising MCB and socket box of reputed make , 25 Amp, 240 volt, 50 Hz, complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |