| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Repairs to roof treatment, joinery, flooring, plastering, plumbing and sanitary fitting including internal electrification in 2 ASD at Beas under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and directed. |
| 3 | Demolition of mud in roof any thickness incl plastering abd leeping removed complete all as specified and directed. |
| 4 | M&L for screed bed or bedding layer of mortar 15 mm thick as cement mortar 1:4 with WPC for laying floor finishes complete all as specified and directed. Note:- Supply only of water proofing compound shall be measured and paid for separately under relevant items of this schedule |
| 5 | Supply only integral water proofing compound (W.P.C) ISI marked (1.5% wt of cement) complete all as specified and directed. |
| 6 | M&L for preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyester reinforcement 3mm thick superior multi polymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed. |
| 7 | M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) of average thickness 75mm to be provided in slope complete all as specified and directed. |
| 8 | M&L for 40mm thick brick tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 with Jointing & Pointing in cement mortar (1:3) mixed with 5% of crude oil by wt of cement complete all as specified and directed. |
| 9 | - ditto - all as per item No. 7 above but except brick tiles complete all as specified and directed. |
| 10 | Cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc; and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and directed. |
| 11 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 12 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and smooth without using extra cement, complete all as specified and as directed. |
| 13 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and fair without using extra cement, complete all as specified and as directed. |
| 14 | M&L for rendering 5mm thick on fair faces of brick or concrete surfaces in cement mortar 1:3 on ceiling finished even and smooth without using extra cement, complete all as specified and as directed. |
| 15 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over and including a coat of chalk whiting/priming on plastered surfaces of walls, complete all as specified and as directed. |
| 16 | M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over and including one coat of appropriate primer complete all as specified and as directed. |
| 17 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash over and including a coat of primer complete all as specified and as directed. |
| 18 | Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames), complete all as specified and directed. |
| 19 | Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames), complete all as specified and directed. |
| 20 | Taking down shutters not exceeding 1.00 sqm but not exceeding 2.00 sqm each (without taking off chokhats) complete all as specified and directed. |
| 21 | Taking down shutters exceeding 2.00 sqm each (without taking off chokhats) complete all as specified and directed. |
| 22 | S&F for box type steel windows/ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings; hinges, handles, tarred hold fasts, PCC blocks etc complete all as specified and directed. (Note:-Wire cloth and glass panes shall be measured and paid separately). |
| 23 | S&F of solid PVC frame as in door, cupboard etc of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube and edges will be painted to match with printed sheets, complete all as specified and directed. |
| 24 | S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; & 5mm thick x 15mm wide PVC sheet beading use inside stiles and rails and decorative PVC beading of 10mm x 10mm (90 degree) used. Paneling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 25 | M&L for framed work as in post, doors or gates and chowkhats of angle or other section with gusset plates, rails, braces, purlin, truss etc, complete, drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening complete all as specified and directed. |
| 26 | S&F of 2nd class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 27 | S&F of 2nd class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed. |
| 28 | M&L for 12mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face and other face is of white as in cupboard, shelves and the like incl fixed with screws to timber frame work on existing wall complete all as specified and directed. |
| 29 | S&F of powder coated anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc to carry load of aluminium door/windows and ventilators minimum size complete all as specified and directed. |
| 30 | S&F for powder coated anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges and tower bolt as reqd, anodised aluminum snap beading screws etc prepared to receive glass, gauze, etc. (without sash bars), and fitted to chowkats complete all as specified and directed. (Note : Glass and wire gauge will be measured and paid separately). |
| 31 | S&F for powder coated anodised aluminium window/ventilator, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges and tower bolt as reqd, anodised aluminum snap beading screws etc prepared to receive glass, gauze, etc. (without sash bars), and fitted to chowkats complete all as specified and directed. (Note:Glass and wire gauge will be measured and paid separately). |
| 32 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified and directed. |
| 33 | S&F of 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed. |
| 34 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wooden beads to steel windows/ wooden doors as in repairs, complete all as specified and directed. |
| 35 | M&L for aluminium mortice lock of 2 levers, vertical type, size 100 mm complete all as specified and directed. |
| 36 | S&F in repair door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed complete all as specified and directed. |
| 37 | S&F of butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed. |
| 38 | S&F of aluminium anodised barrel tower bolts of extruded section of 150mm size etc, complete all as specified and directed. |
| 39 | S&F aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cost or ectruded sections & fixing bolts & sliding bolts is extruded sectins or cast aluminium ally of size 250mm complete all as specified and directed. |
| 40 | S&F aluminium alloy handles 150mm size fabricated type anodised complete all as specified and directed. |
| 41 | S&F in repairs 300mm MS ordinary rat tail rod pattern springs including roller and roller plate complete (Helical door spring) welded to steel chowkats complete all as specified and directed. |
| 42 | S&F in repair mild steel curtain rail chromium plated with fixing brackets, stops, roller incl repair of brackets & knob etc complete all as specified and directed. |
| 43 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. |
| 44 | M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed. |
| 45 | M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 46 | M&L for preparation of old Steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 48 | S&F of frame work of mild steel work in tubular trusses/purlins including special shaped washer, vertical post, horizontal pipes, bracket, tee, distance pieces, cleat etc, complete using ERW or induction butt welded tubes, conforming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 49 | Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed . |
| 50 | S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 51 | S&F of p re-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 52 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc;) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 53 | M&L for gypsum board 12mm thick as in seamless ceiling with necessary GI frame work incl fittings and putty work as required to seal the joints etc complete all as specified and directed. |
| 54 | S&F 6mm thick PVC hollow wall paneling plain/coloured/printed fixed with screws to wall and corner, edges of panels be sealed with appropriate arrangement, colour and pattern as approved complete all as specified and as directed. |
| 55 | Dismantling of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed. |
| 56 | M&L for brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 57 | - dotto - all as per item No.54 above but except bricks including cleaning from mortar etc; complete all as specified and directed. |
| 58 | M&L for brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 59 | Dismantling floor, hearth and wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 60 | M&L for 40mm thick PCC 1:2:4 Type B-1 20mm graded stone aggregates as in flooring finished even and rough to receive the topping layer smooth complete all as specified and directed. |
| 61 | M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed (1:4) complete all as specified and directed. |
| 62 | M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles 0.36 sqm as in Skirting etc, set and jointed in neat cement slurry and pointed in white or colours cement to match with tiles and including 15mm thick screed bed in cement mortar 1:6. Complete all as specified and directed. |
| 63 | M&L for coloured non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement match the shade of tile including 15mm thick screed bed (1:4) complete all as specified and directed. |
| 64 | M&L for coloured glazed ceramic tiles in vertical surfaces 450x300x7 thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour with 15mm thick cement screed bed (1:4) complete all as specified and directed. |
| 65 | M&L for machine cut kota stone slab flooring for platform and floor 20-22 mm thick laid and jointed in grey cement slurry mixed with pigment to match the shade of slab including cutting and polishing bedded on 15mm thick bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 66 | M&L for machine cut kota stone slab as in skirting 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 15mm thick screed bed 1:4 complete all as specified and directed. |
| 67 | M&L for 16-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 68 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for etc complete all as specified and directed. |
| 69 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (20mm graded stone aggregate) as in plinth protection finished even and smooth (without using extra cement), complete all as specified and directed. |
| 70 | M&L for PCC type B-0 (1:2:4) (using 20mm graded crushed stone aggregate) as in parapets walls, benching, coping and filling at junction of brickwork and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete including use of formwork (straight or curved) complete all as specified and directed. |
| 71 | Demolition of RCC chajjas and reinforcement concrete of any description including facilitate in cutting of reinforcement and removing rubbish off the premises of cantonment complete all as specified and directed. |
| 72 | M&L for RCC 1:1.5:3 , type B-1, using 20 mm nominal size graded crushed stone aggregate as in chajjas, roofs, landings, balconies, canopies, deck slabs, shelves and any similar work and the like complete all as specified and directed. |
| 73 | M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia, complete all as specified and as directed. |
| 74 | M&L for formwork to sides, soffits and flat surface of concrete of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams etc complete all as specified and directed. |
| 75 | S&F in repair; vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc complete all as specified and directed. |
| 76 | S&F in repairs vitreous china wash down water closet pan orrisa pattern size 580x 440mm white with integrated foot rest, making connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc complete all as specified and directed. |
| 77 | S&F in repairs vitreous china wash down Water closet pan (pedestal pattern) \\"with plastic closet seat cover closed pattern with flat bottom and cover and mild steel chromium plated hinging divice (excluding flusing cistern and flush pipe) in repairs complete all as specified and directed. |
| 78 | S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern, low level with inlet ball valve float, handle, aluminium brackets for bottom support, including flush pipe 32mm bore fixing in position complete all as specified and directed. |
| 79 | S&F in repairs vitreous china urinal, half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed. |
| 80 | S&F in repairs urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 81 | S&F in repairs waste coupling suitable for urinals, bore dia of discharge pipe 32mm of PTMT (half or full threaded), (Minimum weight 45gms), complete all as specified and directed. |
| 82 | S&F in repairs 32mm waste coupling of PTMT (half or full threaded) (minimum weight 40mm-60 gms) with PVC waste pipe for wash hand basin fixed in repair complete all as specified and as directed. |
| 83 | S&F in repairs brass chromium tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed. |
| 84 | S&F in repairs fancy type 15mm bore bib tap cast copper chromium plated long body with crutch or butter fly handle, screwed down, screwed for iron pipe or bore brass ferrule complete all as specified and directed. |
| 85 | S&F in repairs fancy type pillar tap, cast copper alloy, with capstan heads, 15mm bore dia of pipe chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed. |
| 86 | S&F in repairs 600x450mm bevelled edged mirror of selected quality glass , mounted on 6mm thick AC building board fixed with PVC rawl plugs and chromium plated brass screws with cup washer complete all as specified and directed. |
| 87 | S&F in repairs PVC connection 600mm long with brass nuts suitable for 15mm bore pipe complete all as specified and directed. |
| 88 | S&F in repairs brass chromium plated shower rose with or without swivel joints, 125mm size with arm including fixing to steel pipe or union complete all as specified and directed. |
| 89 | S&F for 15mm chromium plated stop/angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union and fixed complete all as specified and as directed. |
| 90 | S&F for 110mm Size of PVC (SWR) 'P' trap complete all as specified and as directed. |
| 91 | Taking down rain water pipes (any size and pattern), including all fittings, heads, shoes, bends, swan necks, etc. removal from site (measured overall as fixed along the centre line or fittings and accessories) complete all as specified and directed. |
| 92 | S&F of PVC rain water pipes (SWR) 110mm dia single socketed, in any length with rubber joints, fixed to walls with flat iron clamps complete all as specified and directed. |
| 93 | S&F of PVC (SWR) bends ISI marked any radius of 110 mm bore complete all as specified and directed. |
| 94 | S&F of PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed. |
| 95 | S&F of PVC (SWR) bends ISI marked any radius of 75 mm bore complete all as specified and directed. |
| 96 | S&F of floor grating 100mm dia of PTMT(Minimum weight 25gms) complete all as specified and directed. |
| 97 | S&F of PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed. |
| 98 | S&F of PVC (SWR) floor trap 75mm dia including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 (including cutting in existing walls, removing the old and place the new pieces and making good the disturbed portion) complete all as specified and directed. |
| 99 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as specified and directed. |
| 100 | M&L for cement concrete type D2, 1:4:8 (40mm graded stone aggregate) as in floor, foundations, filling and mass concrete, complete all as specified and directed. |
| 101 | M&L for screed bed or bedding layer of mortar 15 mm thick cement mortar (1:6) for laying floor finished complete all as specified and directed. |
| 102 | M&L for chequered cement concrete tiles 30cmx30cmx20-25mm thick, set jointed and pointed in neat cement slurry in floors with pigment complete all as specified and directed |
| 103 | M&L for sand filling under interlocking tiles including consolidation for laying floor finished complete all as specified and directed. |
| 104 | M&L for machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade for laying floor finishes complete all as specified and directed. |
| 105 | Taking up or down steel tubing incl connection, 15mm bore unserviceable pipe for removal to store complete all as specified and directed. |
| 106 | S&F of mild steel tubes, 15 mm bore, medium grade galvanized with all fittings and fixed to walls, ceiling or laid under floors incl excavation complete all as specified and directed. |
| 107 | Taking up or down steel tubing incl connection, 20mm bore unserviceable pipe for removal to store complete all as specified and directed. |
| 108 | S&F of mild steel tubes, 20 mm bore, medium grade galvanized with all fittings and fixed to walls, ceiling or laid under floors complete all as specified and directed. |
| 109 | S&F of 20mm Gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipes or for union and fixed complete all as specified and as directed. |
| 110 | Disconnecting existing PVC water tanks including lowering and change of entire GI pipe and cleaning of tank. After this tank should be re-installed on existing position complete all as specified and directed for tank capacity upto 500 ltr. Note: Taking down and fixing of new GI tubing measured and paid separately. |
| 111 | S&F in repair new rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), ISI marked, white/coloured, hoisted & fixed in position , capacity 500 litres, including dismantling of unserviceable tank and removing from site complete all as specified and directed. |
| 112 | Disconnecting existing PVC water tanks including lowering and change of entire GI pipe and cleaning of tank. After this tank should be re-installed on existing position complete all as specified and directed for tank capacity upto 1000 ltr. Note: Taking down and fixing of new GI tubing measured and paid separately. |
| 113 | S&F in repair new rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), ISI marked, hoisted & fixed in position , capacity 1000 litres, including dismantling of unserviceable tank and removing from site complete all as specified and directed. |
| 114 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed. |
| 115 | M&L in repair for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor (FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC casing caping with all accessories including 1.5 sqmm copper multistrand conductor (FRLS) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed.Note :- Sunken box , hylam plate will be measured and paid separately |
| 116 | One light point controlled by one, one way switch complete all as specified and directed |
| 117 | One fan point controlled by one, one way switch complete all as specified and directed |
| 118 | One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and directed |
| 119 | One socket outlet 3 Pin, 5 Amp on same board complete all as specified and directed |
| 120 | One bell point controlled by one bell push complete all as specified and directed |
| 121 | One light point controlled by two, two way switch complete all as specified and directed |
| 122 | - ditto - all as per item No 114 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 123 | M&L in repair for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor ( FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor (FRLS ) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed.Note:- Sunken box , hylam plate will be measured and paid separately |
| 124 | One light point controlled by one, one way switch complete all as specified and directed |
| 125 | One fan point controlled by one, one way switch complete all as specified and directed |
| 126 | One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and directed |
| 127 | One socket outlet 3 Pin, 5 Amp on same board complete all as specified and directed |
| 128 | One bell point controlled by one bell push complete all as specified and directed |
| 129 | - ditto - all as per item No 116 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 130 | - ditto - all as per item No 116 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 131 | M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FRLS) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with white frame for modular fittings of required size for 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :- |
| 132 | One light point controlled by one, one way switch complete all as specified and directed |
| 133 | One fan point controlled by one, one way switch complete all as specified and directed |
| 134 | One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and directed |
| 135 | One socket outlet 3 Pin, 5 Amp on same board complete all as specified and directed |
| 136 | One bell point controlled by one bell push complete all as specified and directed |
| 137 | - ditto - all as per item No 118 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board |
| 138 | S&F in repair switch piano flush type single pole one way 6 Amp complete all as specified and directed |
| 139 | S&F in repair switch piano flush type single pole one way 15 Amp complete all as specified and directed |
| 140 | S&F in repair Bell push flush type 5 amp complete all as specified and directed |
| 141 | S&F in repair socket out let 2 in 1, 3 pin 5 Amp flush type complete all as specified and directed |
| 142 | S&F in socket out let 2 in 1, 3 pin 15 Amp flush type complete all as specified and directed |
| 143 | S&F in switch modular piano flush type single pole one way 5- 10 Amp complete all as specified and directed |
| 144 | S&F in modular switch piano type single pole one way 15 Amp complete all as specified and directed |
| 145 | S&F in modular socket out let 2 in 1, 3 pin 15 Amp flush type complete all as specified and directed |
| 146 | S&F in modular socket out let 2 in 1, 3 pin 5/6 Amp flush type complete all as specified and directed |
| 147 | S&F in repair modular bell push switch one module complete all as specified and directed. |
| 148 | M&L for ceiling rose, surface bakelite 65x17.50mm of three terminals PVC/Polycarbonate, isolated body complete all as specified and directed. |
| 149 | Taking down old unsv sub main and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper conductor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note:- Two run of 6.00 Sqmm cable one run of 6.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) |
| 150 | S&F in repair LED batten tube light (4ft) for surface and pendant applications.18/ 20 watt, Colour Temp 3000 K 5000 K complete all as specified and directed |
| 151 | S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Colour Temp 3000 K 5000 K complete all as specified and directed |
| 152 | S&F in repair PVC insulated aluminium 6 Sqmm 2 core sheathed cable complete all as specified and directed |
| 153 | S&F in repair modular switch 6 Amp 250 V AC one way one module as per suitability of Frame already existing on work site complete all as specified and directed. |
| 154 | S&F in repair modular switch 16 Amp 250 V AC one way with indicator one module as per frame suitability already existing on work site complete all as specified and directed. |
| 155 | S&F in repair modular socket, 6A - 2/3 pin combined 2 module as per frame suitability already existing on work site complete all as specified and directed. |
| 156 | S&F in repair modular socket 6A/16A - 2/3 pin combined 2 module on work site complete all as specified and directed. |
| 157 | S&F in repair modular fan regulator step type, 100 - 2 module on work site complete all as specified and directed. |
| 158 | S&F in repair in repair metal flush mounting box of 1/2 module complete all as specified and as directed. |
| 159 | S&F in repair in repair metal flush mounting box of 3 module complete all as specified and as directed. |
| 160 | S&F in repair in repair metal flush mounting box of 4 module complete all as specified and as directed |
| 161 | S&F in repair in repair metal flush mounting box of 6 module complete all as specified and as directed. |
| 162 | S&F in repair in repair metal flush mounting box of 8 module complete all as specified and as directed. |
| 163 | S&F in repair white cover plate with frame, 1 module complete all as specified and as directed. |
| 164 | S&F in repair white cover plate with frame, 2 module complete all as specified and as directed. |
| 165 | S&F in repair white cover plate with frame, 3 module complete all as specified and as directed |
| 166 | S&F in repair white cover plate with frame, 4 module complete all as specified and as directed. |
| 167 | S&F in repair white cover plate with frame, 6 module complete all as specified and as directed. |
| 168 | S&F in repair white cover plate with frame, 8 module complete all as specified and as directed. |
| 169 | S&F in repair electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan complete all as specified and as directed. |
| 170 | S&F in repair PVC/Polycarbonate lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type with back plate suitable for batten fittings complete all as specified and as directed. |
| 171 | S&F in repair PVC gang box for mounting switches 01 module complete all as specified and as directed. |
| 172 | S&F in repair PVC gang box for mounting switches 02 module, complete all as specified and as directed. |
| 173 | S&F in repair PVC gang box for mounting switches 06 module, complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail