| 1 | S&F semi perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 476 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick ( galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiling using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2mm. galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws including taking down old ceiling board. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge including dismantling existing asbestos sheet false ceiling textile coverings including frames (if any) and cover fillets complete all as specified and directed.NOTE : -Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed. |
| 2 | S&F 5 mm thick plain colour PVC sheet hollow interlocking wall panelling of width 250 mm for wall panelling inclusive of fixing on wall with screws and solvent alongwith PVC 'U' and 'L' beading at corner and end portion where ever required of matching colour including taking down of existing wall lining, board or insulation board/panelling including cover fillets of any type and thick complete all as specified and as directed.NOTE : - Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed. |
| 3 | Taking down Chowkats With shutters(without taking of shutters from the frames) or frames exceeding 1.5 Sqm but not exceeding 4 sqm including dismantling of brick work for hold fast complete all as specified and as directed. |
| 4 | S&F anodised powder coated aluminium door made out hollow aluminium section as mentioned below. Each door having 02 Nos disk or D type handle of 200 mm long , two Nos aluminium tower bolts of 200 size , one No mortice lock of six levers with key in duplicate regulated by double action hydraulic floor door spring (Make - Sandhu/Titz) shutters to be partly glazed with 5mm thick tinted glass and partly panelled with 12mm thick prelaminated particle board fixed with glazing clips, rubber beading/gasket anodised aluminium beading screws etc complete all as specified and as directed. Make :- Anodised aluminium section : HINDALCO/JINDAL/INDALCOGlass : SAINT GOBAIN/MODI GUARD/TATACHOWKHATS SIZE : 100 X 44 X 1.60 MM THICK SHUTTERS VERTICLE STYLE : 100 X 44 X 1.60MM SHUTTERS LOCK RAIL : 150 X 44 X 1.60MM SHUTTERS BOTTOM RAIL : 200 X 44 X 1.60MM |
| 5 | Demolition of floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish/demolished material off the premises complete all as specified and directed. |
| 6 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) jointless area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed with white or colour cement to match the surface.over screed bed or bedding layer 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 7 | M&L for coloured glazed designer ceramic tiles 300 x 450 x 7 to 8mm thick on vertical surface as in dado/skirting and jointed in neat cement slurry and pointed with white/colour cement to match with the surface over 15mm thick rendering in CM 1:4 complete all as specified and directed. |
| 8 | M&L for vitrified ceramic tiles 10mm thick in light/dark shade (square/rectangular) area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed with white or colour cement to match the surface.over screed bed or bedding layer 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 9 | All as per BOQ srl item No. 8.00 above but as in skirting including 10mm thick in CM 1:4 rendering as in backing coat complete all as specified and directed. |
| 10 | Demolition of PCC in ground floor and pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed. |
| 11 | M & L for 100mm thick PCC 1 :4 :8 type D-2 ( using 40mm graded mechanically crushed stone aggregates ) as in sub base of floors complete all as specified and directed. |
| 12 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 ( using 20 mm graded mechanically crushed aggregate) as in plinth protection/path laid in bays incl finishing the concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 13 | M&L for PCC (1 : 2 : 4) type B0 using 12.5mm graded mechanically crushed stone aggregates as in roof kerbs, mud stop, benching, coping, surface channel, padding and the like complete all as specified and directed. |
| 14 | M&L for chequered cement concrete pre polished colour tiles 20cmx20cmx25mm thick set and jointed in neat cement slurry in floor using grey cement with pigment including 20 mm thick screed bed in CM 1:6 complete all as specified and as directed |
| 15 | M&L for prepolished 60 mm thick rubber moulded double glossy coloured designer interlocking tiles made of M-35 design mix concrete, laying over 50 mm thick sand cushioning, with the crushing strength not less than 250 Kg/Sqcm of approved design and shape, complete all as specified and directed |
| 16 | Dismantling of stone slabs and tiles of any description or thickness laid dry or laid dry and pointed in any mortar in floors, aprons etc complete all as specified and as directed. |
| 17 | M&L for 20mm thick granite stone slab as in shelves over cooking platform, machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 20mm thick screed bed in CM 1 : 6 etc complete all as directed. |
| 18 | Demolition of brick work built in cement mortar complete all as specified and as directed |
| 19 | M&L for brick work with sub class 'B' brick (old size) straight or curved on plan exceeding 6m mean radius in CM (1:6) complete all as specified and as directed |
| 20 | Taking down cement plaster on brick wall including racking out joints,soffits of slabs/chajja/sunshaded hacking for keys, scrubbing down with water etc complete all as specified and as directed |
| 21 | M&L for rendering 15mm thick on fair face of brick walls or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed |
| 22 | M&L for rendering 15mm thick on fair face of brick walls or concrete surfaces in CM 1:4 mixed with WPC @ of 3% by weight of cement finished even and smooth without using extra cement complete all as specified and as directedNote: WPC shall be measured & paid separately. |
| 23 | Supply only Dr fixit integral WPC /liquid complete all as specified and directed. Please Enable Macros to View BoQ information |
| 24 | Supply only Dr fixit integral WPC /liquid complete all as specified and directed. Please Enable Macros to View BoQ information |