| 1 | Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 2 | M&L for complete removal of existing treatment on old painted surfaces of walls by scrapping and removing layers of all wall finishes including cleaning, watering to make the surface clean and free from dust, etc including necessary scaffolding, safety and protective measures complete all as specified and directed.(NOTE: This item shall not be considered for areas measured under Item No. 01 here-in-before) |
| 3 | M&L for 10 mm thick rendering using factory made water-resistant ready-mix plaster on internal fair faces of brickwork or concrete surfaces of walls, applied in accordance with manufacturer's specifications and recommendations, finished even and smooth without using extra cement, including curing and all incidental works, complete all as specified and directed by the Engineer-in-Charge.(Make: Ultratech Readiplast / SmartCare Ready Mix Plaster / JSW Enduroplast or equivalent approved) |
| 4 | -ditto- but for 5mm thick rendering on ceilings |
| 5 | M&L for 15 mm thick rendering using factory made water-resistant ready-mix plaster on external fair faces of brickwork or concrete surfaces of walls, upto four storey height, applied in accordance with manufacturer's specifications and recommendations, finished even and fair, including curing, scaffolding, protective measures and all incidental works, complete all as specified and directed by the Engineer-in-Charge.(Make: Ultratech Readiplast / SmartCare Ready Mix Plaster / JSW Enduroplast or equivalent approved) |
| 6 | M&L for Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the Ratio 1:1:1 shall be applied and finish Even, complete all as specified and directed. |
| 7 | S&F in repair Non-asbestos Fiber Cement Building Boards 4.0mm thick, fixed to Walls with Rawl Plugs and Steel Screws complete all as specified and directed. |
| 8 | M&L for preparing new/undecorated plastered surfaces of walls, applying 1.5 mm thick wall putty in two layers of 0.75mm thickness each, including rubbing down with sand paper to obtain smooth and even surface, applying one coat of suitable primer and finishing with two coats of acrylic distemper of approved shade/tint, complete all as specified and directed by Engineer-in-Charge |
| 9 | M&L for preparing newly Plastered surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and directed. |
| 10 | M&L for preparation of newly plastered surfaces and finished with two coats of exterior acrylic emulsion paint (having anti-dust & anti-algae properties) duly mixed with stainer to achieve approved Tint/shade over a coat of suitable exterior primer, applied to new wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer's instructions, up to 4 storey height incl necessary scaffolding safety gear etc complete all as specified and directed. |
| 11 | M&L preparing newly Rough Cast plastered surfaces of Walls and applying two Coats of Exterior Emulsion Paint (having anti-dust & anti-algae properties) duly mixed with stainer to achieve approved Tint/shade over a coat of suitable exterior Primer (as per Manufacturer's instructions), complete all as specified and directed. |
| 12 | M&L preparing old Distempered surfaces of Walls/cement fibre boards including filling the existing Nails/Screw Holes, etc. and applying One Coat of Acrylic Distemper (of approved tint) with rollers complete all as specified and directed. |
| 13 | M&L for preparing old treated/decorated surfaces of ceilings and applying One Coat of White Wash, complete all as specified and directed. |
| 14 | M&L for preparing old treated/decorated surfaces of walls and applying One Coat of White Wash, complete all as specified and directed. |
| 15 | M&L preparing old decorated/painted Wood and Wood Based Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (1st quality), complete all as specified and directed. |
| 16 | M&L preparing old Treated/Painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and directed. |
| 17 | M&L preparing old Decorated/Treated Plastered surfaces of Exterior Walls, any type (plain or rough plastered) upto Four Storey by brooming down or steel wire brushing and scraping down, filling of cracks with suitable paste and applying with rollers One Coat of Exterior Emulsion Paint (having anti-dust & anti-algae properties) with approved Tint, applied with rollers to wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer's instructions, upto 4 storey height including necessary scaffloding complete all as specified and directed. |
| 18 | -ditto- but with Two Coat of Exterior Emulsion Paint (having anti-dust & anti-algae properties) on old Decorated/Treated Plastered surfaces. |
| 19 | Demolition Brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., and removal of debris outside AF land complete all as specified and directed. |
| 20 | M&L for Brick Work with Fly-Ash Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and directed. |
| 21 | M&L Brick work using Serviceable Bricks obtained from Item No. 21 here-in-before including removing old Mortar, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in cement mortar 1:6, complete all as specified and directed. |
| 22 | Demolition Cement Concrete (Reinforced) of kitchen slab, and similar work (reinforcement cut as required to facilitate demolition) and removing debris, etc. to Outside MOD Land, complete all as specified and directed.(Note: Old reinforcement shall be measured under Sch of Credit) |
| 23 | M&L Reinforced Cement Concrete 1:2:4 type B0 (12.5mm graded stone aggregate) as in Shelves, Chajja, Facia, Sunshade and Similar Items and smooth finishing at Top side using extra Cement, complete all as specified and directed.(NOTE: MS reinforcement & Formwork shall be measured and paid seperately) |
| 24 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for rough finished surfaces complete all as specified and directed. |
| 25 | M&L TMT Bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hoping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia or securing with Clips, complete all as specified and directed. |
| 26 | Taking down carefully existing butt hinges, handles, tower bolts, sliding door bolts, rat-tail springs, floor door stoppers and similar door/window fittings of any description, including removal of screws/fasteners, making good disturbed surfaces and stacking serviceable materials as directed, complete all as specified and directed. |
| 27 | Taking down Shutters of any description exc 1.0 sqm and not exc 2.0 Sqm each, keeping aside for re-use or removal from site complete all as specified and directed. |
| 28 | Refixing of Shutter of any description, area exc 1.00 Sqm and not exc. 2.00 Sqm Each, in same opening after resecuring or easing and adjusting, etc., complete all as specified and directed. |
| 29 | Taking down damaged/unserviceable Steel/Wooden Chowkat or Frame exc. 1.50 Sqm but not exc. 4.00 Sqm Each with shutter( without taking off shutter from the frame) and removal from site complete all as specified and directed. |
| 30 | Taking down damaged/unserviceable Steel/Wooden Chowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed. |
| 31 | Taking down damaged/unserviceable PVC Chowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site complete all as specified and directed. |
| 32 | S&F factory made single-extruded solid WPC (Wood Polymer Composite) door/window/clerestory window frames of size 45 × 75 mm, manufactured from virgin PVC polymer (K-value 58–60), calcium carbonate, natural fibres and non-toxic additives, termite/borer proof, water/moisture proof and fire retardant, having minimum density 750 kg/m³, fabricated with mitred joints using PVC solvent cement and SS screws, and fixed in position with MS holdfasts/lugs or SS dash fasteners complete all as specified and directed.(Note: Holdfasts/lugs or dash fasteners shall be measured and paid separately. Minus 5 mm tolerance in width and depth of profile shall be permissible. No extra payment shall be made for positive variation in profile dimensions.) |
| 33 | -ditto- but WPC frame of size 100 x 50 mm single rebated type |
| 34 | -ditto- but WPC frame of size 125 x 65 mm double rebated type |
| 35 | S&F factory made single extruded solid WPC (Wood Polymer Composite) plain flush door shutter, 30 mm thick, manufactured from virgin PVC polymer (K-value 58-60), calcium carbonate, natural fibres and non-toxic additives, having minimum density 650 kg/cum, screw withdrawal strength 1800 N (Face) & 900 N (Edge), compressive strength 50 N/mm², modulus of elasticity 850 N/mm², Class-A flame resistance and termite/borer proof, water/moisture proof and fire-retardant properties, fixed complete all as specified and directed.NOTE: Stainless steel butt hinges and SS screws shall be measured and paid separately under appropriate items. |
| 36 | -ditto- but for 35 mm thick WPC flush shutter Please Enable Macros to View BoQ information |
| 37 | -ditto- but for 35 mm thick WPC flush shutter Please Enable Macros to View BoQ information |