| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 2 | Cartage of ballast ,kakar, coal & sand including loading & unloading but excluding stacks on pakka roads. |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil 1.50 to 3.00 Mtr |
| 5 | 3.00 to 4.50 Mtr |
| 6 | 4.50 to 6.00 Mtr |
| 7 | Extra under foul condition |
| 8 | Extra under foul condition |
| 9 | Extra under foul condition |
| 10 | Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete. |
| 11 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 12 | Providing and injecting chemical emlusions for pre-construction anti-termite treatement and creating continious chemical barrier under and all round the column pits, wall trenches, excavation top surface of plinth filling, junction, external perimeter of buildings, expamsion joins surrounding of pipes and conduit etc. complete as per technical specifications. (plinth area of the building at ground level shall only be measured for payment) with chlorpyriphos/Lindance E.C. 20% with 1% concentration or equivalent under 10 years guarantee. |
| 13 | Cement Concrete Works Cement concrete with 4cm gauge approved stone ballast, Coarse sand & Cement in the proportion of in 8:4:1 (8 graded stone aggregate 40 mm nominal size : 4 Coarse sand :1 Cement ) including supply of all materials, Labour, Tools & Plants etc. reqired for proper completion of the work. 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 14 | Extra 20% for Under Subsoil Condition |
| 15 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with Coarse sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 16 | Reinforced Cement Concrete works Centering and shuttering including strutting, propping etc. and removal of form for all heights Foundations, footings, bases of columns, etc. for mass concrete |
| 17 | Extra 20% for Under Subsoil Condition |
| 18 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 19 | Suspended floors, roofs, landings, balconies and access platform |
| 20 | Cast-in-situ shelves |
| 21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Stairs, (excluding landings) except spiral-staircases |
| 24 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 25 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 26 | Edges of slabs and breaks in floors and wallsUnder 20 cm wide Under 20 cm wide |
| 27 | Weather shade, Chajjas, corbels etc., including edges |
| 28 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 29 | Supply and Installation, fabrication of 10mm cold ruled sheet piles including all required machinery such as vibration hammer and excavator/crane, complete manpower, fuel (diesel), tools and tackles. Sheet piles shall be driven into the ground till the soil profile detected goes to a maximun depth of 6.0 metres with completion of the sheet works for bracing of sheet piles and support structure etc. all complete as specified and as directed by the Engineer-in-Charge. Sheet Pilling |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all Complete upto plinth level & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D Thermo-Mechanically Treated bars of grade Fe-500D. |
| 31 | Extra 20% for Under Subsoil Condition |
| 32 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level |
| 33 | Extra 20% for Under Subsoil Condition |
| 34 | All works above plinth level upto floor V level |
| 35 | Extra for providing richer mixes at all floor levels. |
| 36 | Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. |
| 37 | Extra for providing richer mixes at all floor levels.Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)Note:- Excess/less cement over the specified cement content used is payable /recoverable separately(DAR/5.34.1/ased on UPPWD/SOR-2020) |
| 38 | STEEL WORKS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 39 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces Using M.S. angels 40x40x6 mm for diagonal braces |
| 40 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes Hot finished welded type tubes |
| 41 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 42 | Providing and fixing ball bearing for rolling shutters. |
| 43 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. |
| 44 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 45 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 46 | MASONARY WORKS M-150 brick work in 1:4 cement & Coarse sand 2.20 F.M mortar in foundation and plinth including supply of all materials labour complection of the work Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 47 | Brick work with 1:4 M150 brick 1:4 in 1:4 one cement & four Coarse sand of 2.20 F.M. mortar in foundation and plinth including supply of all materials labour complection of the work Half Brick wall |
| 48 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 49 | M-150 brick work in 1:4 cement & Coarse sand 2.25F.M mortar in super structure above plinth leve including supply of all materials labour complection of the work |
| 50 | Same as titem no. 305 but in the 1:4 one cement & four Coarse sand of 2.20 F.M. motar |
| 51 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 52 | FLOORING & WALL CLADDING Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite Marble of any colour and shadeArea of slab over 0.50 sqm. |
| 53 | Granite Marble of any colour and shade Area of slab over 0.50 sqm. |
| 54 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work |
| 55 | Granite Work |
| 56 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete |
| 57 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 58 | Providing and laying Ceramic glazed floor tiles of required size (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 59 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 60 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm |
| 61 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 62 | Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 63 | Providing and fiixng 18 mm thick granite stone in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete. |
| 64 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 65 | Polished Granite stone slab colour of Sadarali grey or equivalent |
| 66 | Extra for pre finished nosing to treads of steps of marble stone. |
| 67 | Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. |
| 68 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 69 | Dark shade pigment using ordinary cement |
| 70 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 71 | Antiskid finish of size of Tile 600 x 600 mm |
| 72 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 73 | 25 mm thick |
| 74 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 75 | CARPET FROM FLOATEX- Providing & Fixing of Forbo Flotex classic series flocked floor covering tiles having a density of 70 million fibres of nylon 6.6 per Sqm , Fire Test EN-13501, Appearence Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, sanitized anti-microbial treatment with resilient waterproof backing ,anti allergic cetrtified by British allergy foundation, anti static, thickness 5.3 mm and approximate weight of 4.5 k.g./sqm of roll form with acoustic sound impact 17dB. Flotex to be installed over cement based self leveling compound for smooth level.. The carpet should be laid complete including SS edge profile at door openings. |
| 76 | Pre-Laminated Wooden FlooringProviding and fixing 8 mm thick prelaminated wooden flooring as per approved Brand,colour and shade and laid on the levelled floor with approved adhesives & underlay including polished edge profile and termination profile for skirting and different flooring, PU polish matt finish etc. with seamless joint, 2 side V-groove finish scratch resistant, moisture resistant, strong and durable, underlayer of supreme profile 8mm polyurathene sheets as directed by the architect on levelled finished floor. complete as per design and drawings, specifications and as directed by the architect.Finish shall be Rich walnut, golden oak, red oak, brown mahogany or as approved by engineer in charge. |
| 77 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 78 | 40 mm thick with 20 mm nominal size stone aggregate |
| 79 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). |
| 80 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 81 | Providing and fixing elevation feature JALI, JHAROKHA, MOULDING and CORNICES - 25 mm thk. for the locations as per the drawings. at all levels made from GRC make Glass fibre reinforced concrete (GRC) using white cement, Quartz Sand, AR Fibres, WaterPlasticizers & COLOR in approved shape, size and length as per the design and drawings and as per specifications, mix design. The typical GRC items should be of sizes as per the drawings. Fixing of GRC items shall be with help of S.S. Screws Fixtures, M.S Angle Cleats, Fissure Plug, and Dowel Pin proper alignment as per drawings (Shop drawings to be submitted by the contractor before the work start). As per approved coating, paint, shade & Finishing with GRC powder & filling the joints with Epoxy sealant neatly between GRC items and primary structures. The fins should be in absolute straight plumb line and length and joins between channels should be neatly filed to make seamless uniform surface across the entire elevation of the building without any visibility to joints. M.S. Fabrication, Scaffolding, Transportation, Labour, etc. should be done by the Contractor as directed by Engineer in charge |
| 82 | DOOR & WINDOW WORK Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length.( hold fast lugs or dash fastener shall be paid for separately). |
| 83 | Second class teak wood |
| 84 | French spirit polishing : |
| 85 | Two or more coats on new works including a coat of wood filler |
| 86 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 87 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 88 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 89 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 90 | 2nd class teak wood |
| 91 | 50x12 mm |
| 92 | Providing & Fixing decorative high pressure 1.0 mm thick laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 93 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 94 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). |
| 95 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately). |
| 96 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. |
| 97 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 98 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm with all material, hardware wastages etc. complete. |
| 99 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 100 | 300x16mm |
| 101 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 102 | 250x10 mm |
| 103 | 150x10 mm |
| 104 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 105 | 125 mm |
| 106 | Providing and fixing factory made uPVC white colour casement /casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 107 | Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 108 | Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 109 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 110 | Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 111 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 112 | 6 mm thk Toughned clear glass for casment window.Total (Consider 80% Glass Portion) |
| 113 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 114 | Upto 5mm depth and 5 mm width |
| 115 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. |
| 116 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 117 | (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: |
| 118 | (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 119 | (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 120 | (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. |
| 121 | In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. |
| 122 | Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. |
| 123 | Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025. |
| 124 | 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 125 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement |
| 126 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. |
| 127 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 128 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 129 | With stainless steel cover plate minimum 1.25 mm thickness. |
| 130 | Providing and fixing approved make & manufacture SS 304 grade D type 600mm pull handle ISI marked with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specification & as directed by Engineer-in-charge. |
| 131 | Providing and fixing approved make and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. |
| 132 | Providing and fixing approved make and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. |
| 133 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. Wedge expansion type |
| 134 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brickmasonry surface backing including drilling necessary holes and thecost of bolt etc complete. |
| 135 | Fastener with threaded dia 6 mm |
| 136 | Fastener with threaded dia 8 mm |
| 137 | Fastener with threaded dia 12 mm |
| 138 | PLASTERING & PAINTING WORK 12 mm cement plaster of mix : |
| 139 | 1:6 (1 cement: 6 Coarse sand) |
| 140 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 141 | Providing and applying 6 mm cement plaster of mix : |
| 142 | 1:3 (1 cement : 3 fine sand) |
| 143 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 144 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 145 | Water thinnable cement primer |
| 146 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 147 | Two or more coats on new work |
| 148 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 149 | Two Coats |
| 150 | Finishing walls with textured exterior paint of required shade : |
| 151 | New work (Two or more coat applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 152 | Providing and Fixing GI chicken wire mesh 24 gauge & 12 mm mesh and 300 mm width for construction joints and chasing in brick work for electrical conduits or water supply pipes including cement slurry and pegs/nails with nailing machine as required before plastering etc. complete |
| 153 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 154 | CEILING WORKS Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 155 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 156 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 157 | Providing & fixing Trap Doors in ceiling made of 19mm thick commercial board/ ply panels placed inside Aluminum channel frame work which is fixed to ceiling framing on all sides and hanged from RCC slabs with GI flats/wires which are fixed with dash fastners, panel to be cladded with 1.00mm thick approved laminate including balancing laminate on inner side, hinged with 50 mm x 50 mm hardwood frame with neat 6 mm groove on all sides including all hardware, SS concealed hinges, concealed SS latch, providing SS cup board locks 2 nos. in each shutters of size 75mm complete as per design & drawing & instructions of Architects. |
| 158 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval |
| 159 | and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. |
| 160 | Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK. |
| 161 | Providing and fixing false ceiling with micro look edge and 15 mm thickness ,easily demountable tile , manufactured from High density glass wool with the visible surface is a batch painted glass tissue in white and the back of the tile should be covered with glass tissue. Tiles should be classified under absorption class A with \\"alpha w \\" value of 0.95 at 200 o.d.s. Sound absorption test results should be measures according to EN ISO 354 and classification according to EN ISO 11654 and the single value rating for NRC and SAA according to ASTM C 423 . Tiles should be easily demountable with the option of weekly dusting and vacuum cleaning . Tiles should have white color \\" White 500 \\" nearest NCS color sample S 0500 - N with 83% light reflectance. The tiles should withstand a permanent ambient RH up to 95% at 30 degree C without sagging, warping and delaminating ( ISO 4611). Should be certified by the Indoor Climate labeling , emission class Rmt for building materials and recommended by Swedish Asthma and Allergy Association . Should have been granted the Nordic Swan eco - label with fully recyclability . The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501 - 1 standard of Europe. Tiles should have a re-cycled content of more than 70%. |
| 162 | False ceiling framing shall be Gypsteel pre coated (Exposed portion only) GI T Grid system in 600x600mm module which includes providing and fixing wall angle(24x24x0.40mm) along the perimeter of the room with help of self-tapping screws (3.5x35) at 300mm centers. Then suspending the main T(40x15x0.30mm) from the soffit with help of soffit cleat, rawl plugs(38x12 dia) and wire rod of dia 4mm with Leveling spring clip(85x30x0.8mm) at 600mm c/c. 600mm Cross T(40x15x0.30 mm) is then interlocked into the pre-cut slots in the main T at 600mm centers in direction perpendicular to the main T to make a grid of 600x600mm.Finally 600mm Cross T(40x15x0.30mm) are then interlocked into the precut slots in the 600mm T at 600mm centers and in direction parallel to the main T. Cross T’s having length more than 600mm are to be supported independently. the rates shall include required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 163 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval |
| 164 | 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. |
| 165 | MISCELLANEOUS WORKS Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 166 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. |
| 167 | 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) |
| 168 | Providing and fixing of Frameless Glass fixed full height partition of any height as per drawings and specifications at all floors with 12mm thick clear toughened glass with all necessary fittings and hardware's of approved make including necessary fixing arrangements. The glass is fixed up with the cill / floor and lintel/ roof beam/ wooden partition by embedding polyester powder coated Aluminium U channel of size 25 mm x 25 mm of 16 gauge. The U bottom will be grouted in the cill / floor and lintel/ partition by chasing the cill / floor and lintel including necessary filling up gaps at sides, top & bottom with required weather proof silicon & backer rod shall be inserted between aluminium channel and glass as well as both inside and outside around the periphery of the glass making the glazing air and water tight etc. all complete as per directions and instructions of Engineer - in - charge at site. The item includes making provisions of fixing frameless glass doors in the partition including SS patch fittings required to fix the door to the partition. All the exposed edges of glass shall be grinded and polished.The Frameless Glass partition shall have wooden frame above the frameless glass. Frame work to go uptil RCC slab above false ceiling, area above false ceiling to be cladded with Calcium silicate board one side. Necessary openings to be made for HVAC requirements in the Calcium silicate board above false ceiling. All full height partitions to extend till the structural glazing. The edge of partition facing structural glazing to be neatly finished in laminate prior to installing. Smoke barriers/ sealants/fire seals to be installed to seal all gaps between structure and partitions, structural glazing and partitions etc. to prevent smoke/ noise/ fire etc. to travel from one room to another or one floor to another.Finished area below False ceiling will be measured and paid for Glass in this item and wooden partition.. |
| 169 | Supply and fixing of Urinal partition with 8 mm thickness, 450 x 900 mm Frosted toughened glass with chamfered edges as per IS codal provisions & EN-12150-1:2015, shall be fixed at proper heights with SS 304 grade fittings & accessories of Bracket. bolts, anchor fasteners, and SS Clips as recommended by the manufacturer and directed by Engineer in charge |
| 170 | Providing and fixing of Saucer Drain of size 600x300x100 mm ( along the sides) in PCC (1:1½:3) complete and provide proper slopes to drain of rain water on the top of drain including all lead lifts etc complete for the finished item of work as per the directions of Bank.Note: (No separate measurements will be considered for the excavation). |
| 171 | Providing Machine for Cutting of Core in R.c.c Slab and in Different Size at the site |
| 172 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 173 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 174 | With common burnt clay F.P.S. (non modular) bricks |
| 175 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. Toilet Cubical Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 304) as per manufacturer's specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. All screws will be of 304 Grade in stainless steel with satin finish. All pilasters are supported by series stainless steel shoe box with MS- Base Plate. The Base of stainless steel shoe box will be anchored to the floor with a clearance height upto 110 mm. Fixing of intermediate panels to the wall shall be stainless steel 'L'- Bracket or stainless U- Channel section are fixed into wall with screw inserts. All screws will be of 304 Grade in Stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 110 mm. All intermidiate panels shall be 12 mm thick, pilasters and door shall be 18 mm thick with edges chamfered complete as per drawing and directions of Engineer- In- Charge. |
| 176 | WATER PROOFING Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 177 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 178 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 179 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. |
| 180 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 181 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 182 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 183 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 184 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: |
| 185 | (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. |
| 186 | (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. |
| 187 | (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. |
| 188 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 189 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : |
| 190 | (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. |
| 191 | (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. |
| 192 | (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. |
| 193 | Using rough kota stone. |
| 194 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : |
| 195 | Using rough kota stone. |
| 196 | Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 197 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 198 | 15 mm nominal outer dia pipes (DAR/18.8.1/Based on UPPWD/SOR-2020)) |
| 199 | 20 mm nominal outer dia pipes (DAR/18.8.2/Based on UPPWD/SOR-2020)) |
| 200 | 25 mm nominal outer dia pipes (DAR/18.8.3/Based on UPPWD/SOR-2020)) |
| 201 | 32 mm nominal outer dia pipes (DAR/18.8.4/Based on UPPWD/SOR-2020)) |
| 202 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work |
| 203 | 32 mm nominal outer dia pipes (DAR/18.9.4/Based on UPPWD/SOR-2020)) |
| 204 | 62.5 mm nominal outer dia pipes (DAR/18.9.7/Based on UPPWD/SOR-2020)) |
| 205 | 100 mm nominal outer dia pipes (DAR/18.9.9/Based on UPPWD/SOR-2020)) |
| 206 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm diameter (DAR/12.41.2/Based on UPPWD/SOR-2020)) |
| 207 | 110mm diameter (DAR/12.41.2/A.R./ Based on UPPWD/SOR-2020) |
| 208 | Providing and fixing brass bib cock of approved quality: 15 mm nominal bore (DAR/18.15.1/Based on UPPWD/SOR-2020)) |
| 209 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 210 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 32 mm nominal bore (DAR/18.17.2/Based on UPPWD/SOR-2020) |
| 211 | 65mm gate valve |
| 212 | Providing and fixing wall mounted water closet (European type) with seat including dual cisten ( Kohlar, Parryware, Roca or equivalent make) |
| 213 | Providing, Fixing,testing and commissioning of Health faucet with regulator with flexible pipe 1.0 m long, wall hooked complete as required with flow rate of 3.5 LPM. |
| 214 | roviding and Fixingt toilet paper holder C.P. brass screw complete as required. DAR 2018/17.3.4.2 |
| 215 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. (DAR/17.5.2/Based on UPPWD/SOR-2020) |
| 216 | Providing and fixing counter top wash basin with piller Tap fitting ( Kohlar, Parryware, Roca or equivalent make |
| 217 | Supply and fixing of 15mm dia angle stop valve of PTMP any colour high pressure screwed for iron pipe ( Minium weight 15 mm - 90 gms ) |
| 218 | Supply and fixing of liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats ( minium weight 105 gms) |
| 219 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With bricks of class designation-150 (DAR/18.33.1//Based on UPPWD/SOR-2020)) |
| 220 | Providing and fixing 600x600 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DAR/17.31/Based on UPPWD/SOR-2020)) |
| 221 | Providing and fixing nahani trap icluding all complete. |
| 222 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 470x420 mm bowl depth 178 mm: (DAR/17.10.1.1/Based on UPPWD/SOR-2020)) |
| 223 | Kitchen sink without drain board |
| 224 | 470x420 mm bowl depth 178 mm |
| 225 | Provide & fixing PVC waste pipe for Sink in complete (40mm dia) |
| 226 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. |
| 227 | 100mm inlet and 100mm outlet |
| 228 | Providing and fixing PVC connection pipe with brass unions. 15 mm nominal bore 45cm length |
| 229 | Providing, fixing, joints and testing in position the following UPVC Pipe confirming to IS:4985 of 10kg/sqcm quickfit type for garden irrigation system cut to required length pipe to be laid below level in trenches up to required depth, including excavation in all kind of soil (hard rock) dewatering, refilling, watering, ramming and removing the surplus excavated material and putting 100 m sand all-around and making good the same. |
| 230 | 160 mm dia. |
| 231 | Providing and fixing Heavy Class SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT & FD. |
| 232 | Size 150 mm X 150 mm |
| 233 | Providing & Fixing of CP Heavy Duty Bottle Trap 32mm. (Complete complying with relavent standard specification and as directed by the Competent authority.)For Wash basin& Urinal & Kitechen sink |
| 234 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : |
| 235 | 100 mm diameter |
| 236 | 150 mm diameter |
| 237 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 238 | Providing, Fixing air purifier container on wall face with necessary rawl plugs and steel screws complete in all respects, including cutting and making good the wall wherever required. |
| 239 | Providing, Fixing, testing and commissioning of raised toilet seat with cover for handicap toilet including providing & fixing CP bolts, nuts, fisher/anchor bolt are required for hangong of WC complete with all accessories. Including cutting & making good the walls & floors wherever required. |
| 240 | Providing, Fixing, testing and commissioning of Adjustable Type Wash Basin with Elbow Oprated Tap for handicap toilet complete with brackets, tracks, waste pipes and other accessories complete including cutting and making good the walls wherever required. |
| 241 | Providing, Fixing, testing and commissioning of wall mounted 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface hinged Hand Rail 750 x 100 mm complete in all respects, including cutting and making good the wall wherever required. |
| 242 | Providing, Fixing grab bar fabricated from 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface 600 mm long grab bar in toilets for physically handicapped complete in all respects, including cutting and making good the wall wherever required. |
| 243 | Providing, Fixing,testing and commissioning solid state, no touch operting, fully hygienic hand drier of approved shade with single blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls complete as required. |
| 244 | Providing and fixing, testing and commissioning of reducing floor drain of 110x63 mm OD as floor drain in cement concrete 1 : 2 : 4 float with floor complete in all respects. |
| 245 | Item code: 12.41.2UP PWD SOR2020P&F on wall face unplasticsed rigid PVC for water supply only conforming to IS: 13592 type A including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expantion / kishan , supreme or equivalante P/F PVC rain water pipes : single socketed pipes. 160 mm diameter |
| 246 | ltem code: SOR Based on DAR-18/12.41.2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382. leaving 10 mm gap for thermal expansion, (i) single sockted pipes. 110 mm diameter |
| 247 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 248 | Coupler 110 mm |
| 249 | Single pushfit Coupler 110 mm |
| 250 | Single tee with door 110x110x110 mm |
| 251 | Bend 87.5° 110 mm bend |
| 252 | Shoe (Plain) 110 mm Shoe |
| 253 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 254 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 255 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter |
| 256 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 257 | Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'C' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in center of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: underground & Over head tanks) All dia |
| 258 | Providing, Fixing PVC Half set Bend 45 110mm Dia. |
| 259 | Providing, Fixing PVC Door Tee 110MM |
| 260 | Providing, Fixing Chilli Clamp |
| 261 | Providing, Fixing Tie Rod-10mm dia with fastner |
| 262 | Providing, Fixing Fastner 10mm |
| 263 | Providing, Fixing C-Channel For 1mtr. |
| 264 | Providing, Fixing U-clamp 150mm Full threading |
| 265 | Providing, Fixing Cowl 110mm Dia. |
| 266 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 267 | Designing thre Irradiation facility for setting up 3000 kCi Gamma Irradiation plant for Setting up an Integrated Export facility with lrradiation and Packhouse unit Supply of Equipment |
| 268 | Supplying, installation, testing and Commissing of product transport system having cell, labyrinth & loading/lunloading conveyors with structure support members, good lift and platform as per specification. |
| 269 | Supplying, installation, and Commissing of Tote boxes of size is as per the design, made of aluminum alloy. |
| 270 | Supplying, installation, and Commissing of a Source holding/ raising mechanism hydraulic Cylinder, interlocked with personnel entry door through SS wire ropes as per specification. |
| 271 | Supplying, installation, and Commissing of Cask handling system with minimum 7.5-ton hoist as per specification. |
| 272 | Supplying, installation, and Commissing of assorted embedment's (Material:MS)/ SS EP for pool and ventiation duct, water pool SS lining as per the design. |
| 273 | Supplying, installation, and Commissing of De Mineralization / RO plant (|f required) / pH meter with fitments as perspecification along with complete pool water circulation system and online filtration arrangement and online pool water conductivity measurement system with conductivity meter. |
| 274 | Supplying, installation, testing and commissioning of field instrumentation & safety systems for the entire irradiation plant as per specification. |
| 275 | Supplying, installation, testing and commissioning of Control system (PLC-based control & safety system with SCADA and HMI backup) as per specification. The PLOC system should be off Siemens/ Rockwell/ Delta make. |
| 276 | Supply if source rack and frame of Design capacity 3000 Kci along with under water Source loading tools and tackles, 2 nos underwater light and all accessories required for source loading. Auxiliary equipment for the plant |
| 277 | Supplying, installation, testing and commissioning of Laboratory equipment for dosimetry as per Specification. detailed Specification of all equipment and accessories has to be given by the bidder/consortium/joint venture/Partnership firm/Pvt. Ltd. |
| 278 | Supplying, installation, testing and commissioning of X-ray package scanneras per specification. |
| 279 | Supply of Radiation protection equipment forplant operators and also personal monitoring system Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail