| 1 | DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group C |
| 3 | DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 6 | DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 7 | DSR Item No. 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 8 | DSR item No.1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 9 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 5/6 amps switch |
| 11 | 3 Pin 5/6 A. socket outlet |
| 12 | DSR item No.1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 13 | 3 Module (100 mmX75 mm) |
| 14 | 4 Module (125 mmX75 mm) |
| 15 | 8 Module (125 mmX125 mm) |
| 16 | 12 Module (200 mmX150 mm) |
| 17 | DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 18 | 25 mm |
| 19 | DSR Item No 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 20 | 3 x 1.5 sq. mm |
| 21 | 3 x 2.5 sq. mm |
| 22 | 3 x 4 sq. mm |
| 23 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 24 | DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 25 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Single pole |
| 27 | Triple pole and neutral |
| 28 | DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, (As per Complete Item No. 14 of the DNIT). |
| 29 | 4 way (4 + 12) Double door |
| 30 | 6 way (4 + 18) Double door |
| 31 | DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 32 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 33 | DSR item no. 8.6.10LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 16 of the DNIT). |
| 34 | 36 Watt |
| 35 | DSR item no. 8.9.5LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 17 of the DNIT). |
| 36 | 18-22 watt |
| 37 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The Bakelite sheet should be of make Super Hylam / Formica / GreenLam make only. |
| 38 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. (As per Complete Item No. 19 of the DNIT). |
| 39 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 20 of the DNIT). |
| 40 | Supply & erection of Cabin Fan 16” sweep (metal body) oscillating type complete with aluminium blades & regulator. The fan should have regulator switch for speed regulation. (As per Complete Item No. 21 of the DNIT). |
| 41 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 22 of the DNIT). |
| 42 | Size 12” Sweep 900 RP. MTR. with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 300-6-1/ Bajaj make Supreme PLUS only. |
| 43 | Size 15” Sweep 900 RP. MTR. with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 380-6-1/ Bajaj make Supreme PLUS only. |
| 44 | Supply and erection of 14 GMS sheet frame of suitable size for erection of exhaust fan. The hole should be suitable required size for exhaust fan shall be cut from the Centre of the sheet duly fixed on existing M.S. glazing/ ventilator. (As per Complete Item No. 23 of the DNIT). |
| 45 | Suitable for 12” / 15” / 18” Exhaust Fan. |
| 46 | DSR item No.9.2.4 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, (As per Complete Item No. 24 of the DNIT). |
| 47 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 48 | S/I/T/C of linear suspended luminaire 4 ft. long made up of extruded aluminium with PMMA diffuser for standalone and seamless end to end connectivity. The fitting is to be installed on existing surface with the help of 2 no. suitable length universal suspensions suitable for quick on site adjustment. (As per Complete Item No. 25 of the DNIT). |
| 49 | DSR item No.2.2.15 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required |
| 50 | 200 A,36KA,FPMCCB |
| 51 | Supply and erection of sheet metal bus-bar chamber on existing surface with required No. of bus-bar strips of suitable length and cross-sectional area, made of copper strips of suitable length and cross-sectional area enclosure made of M.S. sheet 1.6mm thick, (As per Complete Item No. 27 of the DNIT). |
| 52 | Sheet metal bus-bar chamber suitable for 200 Amp. 415 Volts capacity with 4 copper strip Bus-bars each of length 600 mm & cross-sectional area (50mmx3.17mm) enclosure having overall dimensions (1280mm x 550mm x 200mm) nominal. Please Enable Macros to View BoQ information |