| 1 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 2 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:6 and finished even and smooth (without using extra cement) complete all as specified and directed. (height upto 12.50m) |
| 3 | M&L for 5mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 as in ceiling complete all as specified and directed. (height upto 12.50m) |
| 4 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 and to be finished even and smooth (without using extra cement) using WPC complete all as specified and directed. Note:- (i) WPC shall be measured and paid separately(ii) height upto 12.50m |
| 5 | Supply only integral waterproofing compound |
| 6 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 7 | M & L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 8 | M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection finished even & smooth without using extra cement complete all as specified and directed. |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed. |
| 10 | Demolition of Cement Concrete (un-reinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 11 | M&L for PCC 1:2:4 (Type B1 using 20 mm graded aggregate) levelling course, to match the undulations of sub base complete all as specified and directed. |
| 12 | M&L for Non Skid Coloured Ceramic Tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed or bedding layer of 1:6 cement mortar for laying floor finishes complete all as specified and directed. |
| 13 | M&L for Glazed Coloured Ceramic Tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick in vertical surface such as dado / skirting / risers to steps etc., set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including rendering 10 mm thick in cement mortar 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 14 | Taking down Chowkhats or frames not exc. 1.50 sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed. |
| 15 | Taking down Chowkhats or frames exc. 1.50 sqm but not exc. 4 sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed. |
| 16 | Dismantling of timber scantlings 40 Sq cm and over in section in any position unframed work and stacking at site where directed complete all as specified and directed. |
| 17 | Taking down shutter of any description and area exc 1 sqm but nexc 2 sqm complete as specifed and directed |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete as specifed and directed |
| 19 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete as specifed and directed |
| 20 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC Sheet & edges will be painted to match with prelam sheet, reinforced with M.S Square tube, & fixing in opening as per specification & drawing complete as specifed and directed |
| 21 | S&F Factory made solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottomrails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channelhaving a PVC sheet strip of 20mm width stuck inside with solvent cement for stilesand plain colour PVC sheets for top rail, lock rail & bottom rail on either side & asgap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to befitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame atsite as per specification & drawing complete as specifed and directed |
| 22 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as per architectural drawings and the directions of Engineer-in-Charge |
| 23 | Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3 mm (+- 0.2 mm). Window profile with hollow section with multi chamber. Frame (88 mm x 52 mm), sliding sash (42 mm x 67 mm). Sliding mesh Sash (42 mm x 57 mm), Sliding interlock (One vertical length in each shutters) (45.5 mm x 28 mm), Glazing bead (24.5 mm x 16 mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 +– 0.2 mm thick, galvanized steel Frame (30 mm x 18 mm) 02 nos, sliding sash (30 mm x 18 mrn), sliding mesh sash (26 mm x 10 mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners, [Hardware : Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40 mm & required accessories.] Note : The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.) (Area n.exc 2.00 sqm each.) |
| 24 | S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete as specifed and directed |
| 25 | S&F 12 mm thick 'Prelaminated particle board, interior grade,prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specifed and directed |
| 26 | S&F Mortice lock,vertical type size 100 mm 4 lever complete all as specified and directed. |
| 27 | S&F in repair, 100 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed |
| 28 | S&F in repair, 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 29 | S&F in repair, 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 30 | S&F in repair, 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy & fixed complete all as specified and directed. |
| 31 | Taking down steel tubing and connections incl cleaning for refixing or removal from site for 15mm bore pipe all as specified and directed by Engr-in-charge. |
| 32 | All as per srl item No31 here-in-before but 20mm bore pipe |
| 33 | S&F 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls or ceilings or laid in floors of any length complete all as specified and directed by Engr-in-charge. |
| 34 | All as per srl item No- 33 here-in-before but 20mm dia |
| 35 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc) of 20 mm bore of pipe complete all as specified and directed. |
| 36 | S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity, (minimum triple layer), hoisted and fixed in position all as specified in SSR Part-I, including dismantling of old u/s water storage tank complete all as specified and directed. |
| 37 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed. (Minimum weight 210 gms) complete all as specified and directed. |
| 38 | S&F in repair PVC low level flushing cistern complete with siphon handle lever float valve and PVC bend including connecting to ITWC/ ETWC and fixing on wall bracket complete all as specified and directed by Engr-in-charge. |
| 39 | S&F in repair Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm-90gms) complete all as specified and directed. |
| 40 | S&F in repair (15 mm) Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm-90gms/20mm-112gms) complete all as specified and directed. |
| 41 | S&F in repair Bib tap 15 mm size standard or PTMT fancy type any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm 120gms/ 20mm-125gms) complete all as specified and directed. |
| 42 | S&F in repair, Brass Chromium Plated, tubular towel rail, 20 mm dia, D type, 60 cm long between flanges etc complete all as specified and directed. |
| 43 | S&F in repair Pillar taps of PTMT (15 mm )any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm-110gms) complete all as specified and directed. |
| 44 | S&F in repair, 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers complete all as specified and directed. |
| 45 | M&L Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern, flush pipe & Seat and cover for padestal complete all as specified and directed |
| 46 | S&F in repair, Vitreous china wash basin, white, flat back, size 550 x 400 mm excluding taps, waste, chain & plug & porcelain stopper but including bracket & including supply & fixing of 32 mm dia of bore, brass chromium plated waste coupling complete all as specified and directed. |
| 47 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 48 | Taking down of eaves gutter, rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. |
| 49 | S&F 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 50 | S&F 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 51 | Excavating in trenches in soft/loose soil, not exceeding 1.5 metre wide & not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 52 | Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified & directed. |
| 53 | Removing surplus excavated material (soil) to a distance exceeding 250 metre but not exceeding 500 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed. |
| 54 | Material and labour for cement concrete type B1, 1:2:4 (20mm graded stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified. |
| 55 | Demoliton and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) incl PCC bedding & hauching set in cement morter of above dia pipe complete all as specified and directed. |
| 56 | Supply, laying & jointing 150 mm nominal bore (Internal Diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified & directed. |
| 57 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 58 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. |
| 59 | M&L for Salt glazed stone ware gully traps size 150 x 150 mm, square or round mouthed, type ‘P’ including setting and jointing to drains with cement mortar 1:1 including demolition of existing traps complete all as specified and directed. |
| 60 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 61 | S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed. |
| 62 | S&F PVC (SWR) floor trap 75 mm with grating, setting and jointing with solvent cement complete all as specified and directed |
| 63 | S&F in repair PVC (SWR) mulit trap 75 mm with grating, setting and jointing with solvent cement complete all as specified and directed |
| 64 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed |
| 65 | S&F in repair 125mm/ 150mm dia mild steel chromium plated grating fixed on floor trap / nahani trap in Cement mortar 1:6 , all as specified and directed by Engr-in-charge. |
| 66 | S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed in 20 mm bore dia of pipe complete all as specified and directed. |
| 67 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and stacking at site where directed and removal of debris to a outside MOD land and depositing where directed complete all as directed. |
| 68 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 69 | S&F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip & straight flashings (length & girth as fixed) with grade of zinc coating 275 of 1.00mm thick complete all as specified and directed.. ( Height of Bldg upto 12.50mtr) |
| 70 | Demolition Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 71 | M&L suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600x600mm compressing of GI powder coated main runner of dimension 39mmx24mm x 0.8mm thick (Thickness comprising of GI/0.4mm+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length), cross Tee of dimension 29mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4mm+PPPCGS/0.3mm & weight of Tee 0.195Kg for 600mm length) and wall angle of dimension 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.30mm & weight of angle 0.700 Kg for 3050mm length) with and including 6mm thick HPSC (High Pressure Steam Cured) pre-primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 Kg/clip), hold down clips (wt - 0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed. ( Height of Bldg upto 12.50mtr) |
| 72 | EPOXY FLOORING THICKNESS 5 MM 1. SUBSTRATE REQUIREMENTS: Concrete or screed substrate should be a minimum of 25 N/mm2 ,free from laitance ,dust and other contamination. the substrate should be surface dry and moisture shall be 5% and free from rising damp and ground water pressure. grinding and remove all the dust by vaccum Primer : Supply and apply of Epoxy primer HFP 130 /HFP 120 Over the Prepared surface and allow it to dry. Epoxy Under lay : - Providing and applying of Apcoflor LSC 3XI ,Providing and applying 4.00 mm thick over the primed substrate using ,Apcoflor LSC 3 XL of make Asian Paints, 3 component ,stain finish ,self smoothing ,Non tainting and non dusting ,Hard-wearing Abrasion resistant high chemical resistance grade available ,typical use in dry process areas subject to medium duty traffic include clean roos requirement, Apcoflor LSC 3 XI shall be laid at using notch tools followed by spike roll to release all entraped voids and the fully cured topping shall exhibits the typical properties as mentioned in the technical specification on the performance critiria and complete strictly following the coverage and methodology. Supply mixing and appling a Apcofloor SL Epoxy of Asian Paints is a self Paints ,is self smoothing epoxy resin floor finish applied at 1 mm thickness over the Epoxy underaly , Notch shall be used to spread the mixed Epoxy followed by the spike rolling to release the entraped air the cured topping shall attain the following properties ,complete as per the manufacturer's instructions. |
| 73 | Note:- Work shall be executed by company authorised Applicator including Removal of existing Epoxy coating and oiling /greasing flooring adhered to concrete floors ,preparation of concrete floor surfaces including removal of adhesives,ingress in concrete,paint splashes,curing compounds,oil and grease,etc and rectifying undulations to smooth surface by light mechanical scrubbing,grinding or grit/captive blasting followed by vaccum cleaning to remove dust,removal of moisture content,repair the undulations if any all as specify and directed including removing of existing. |
| 74 | All as per above item No 72 here-in- before but 100mm wide yellow lines |
| 75 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coats of oil bound distemper over a coat of primer over a coat of 1-2mm thick birla wall care putty complete all as specified and directed. |
| 76 | M&L for preparation of old decorated surfaces of walls by complete removal of existing treatment and applying two coat of oil bound distemper over a coat of primer over a coat of 1-2mm thick birla wall care putty complete all as specified and directed. |
| 77 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coat of cement based paint over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 78 | M&L for preparation of old painted ceiling surfaces & applying one coat of white wash on ceiling surfaces complete all as specified and directed. |
| 79 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying three coat of white wash on prepared brick work or concrete surfaces complete all as specified and directed. |
| 80 | M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint ordinary tint over one coat of red oxide complete all as specified and as directed. |
| 81 | M&L for preparation of old painted Steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of Synthetic enamel paint (ordinary tint) complete all as specified and directed. |
| 82 | Surface dressing not exc 15 cm deep in soft / loose soil complete all as specified & directed |
| 83 | Excavation in post holes (or similar holes) each not exceeding 0.50 cum in hard/dense soil, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering & removing surplus soil to a distance not exceeding 50 m & making good surface. Complete all as specified & directed. |
| 84 | M & L PCC 1:4:8 type D-2 (Using 40 mm grade aggregate) in foundation, filling and mass concrete complete all as specified & directed. |
| 85 | M&L for Cement Concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified & directed. |
| 86 | M&L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 87 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240. Complete all as specified & directed. |
| 88 | S&F of Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed. |
| 89 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified & directed. |
| 90 | M&L for ENDURA out door tiles 40 cm x 40 cm x 12 mm thick rubberised mould set, jointed and pointed in neat cement slurry as in floors etc including 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying of tiles complete all as specified and directed. |
| 91 | M&L for Moorum/Red Bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled & rammed including watering complete all as specified & directed. |
| 92 | M&L for Hardcore of broken stone or boulders of gauge not exc. 63 mm, deposited, spread & levelled in layers not exc. 15 cm thick, watered & rammed to a true surface complete all as specified & directed. |
| 93 | M & L 15mm thick rendering on fair faces (without using extra cement) of brick work concrete surface in CM 1:4. on external surfaces finished even and smooth complete all as specified and directed. |
| 94 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coat of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 95 | Taking down carefully copper/aluminium point wiring ( light,fan,power point or bell point etc) complete including fixture and fitting such as switches,ceiling rose holders & regulators light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 96 | Taking down carefully copper/aluminium Sub Main wiring/service connection of any size from surface/connected/existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 97 | M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit of white/ivory colour including all accessories after chasing in wall/ceilling etc, heavy duty ISI marked with GI sheet metal boxes 1.2mm thick, 60mm deep with earth dolly, covered with modular white cover plate with inner frame suitable for modular swithes, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 98 | One light point controlled by one, one way switch 5 Amps. |
| 99 | One fan point/exhaust fan point/wall fan point controlled by one, one way switch 5 Amps and regulator. |
| 100 | One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on the same board. |
| 101 | One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on indelpendednt board. |
| 102 | All as per item Srl No 96 here-in-before but using 2.5 Sqmm single core copper conductor cable of multistranded FRLS, PVC insulated unsheathed 1100 volts grade for 5/15 amps witch socket combination point including necessary running of 2.5 Sqmm copper conductor FRLS, PVC wire as earth continuity conductor alongwith wiring an connecting to the common earth dully, complete all as specified and directed. |
| 103 | All as per item Srl No96 here-in-before but using 4 Sqmm single core copper conductor cable of multistranded FRLS, PVC insulated unsheathed 1100 volts grade for metal clad box point including necessary running of 4 Sqmm copper conductor FRLS, PVC witre as earth continuity conductor alongwith wiring an connecting to the common earth dully, complete all as specified and directed. |
| 104 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 105 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 106 | S&F Socket, 6A - 2/3 pin combined 2 module complete complete all as specified and directed. |
| 107 | S&F Socket 6A/16A - 2/3 pin combined 2 module complete complete all as specified and directed. |
| 108 | S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed. |
| 109 | S&F Lamp holder, PVC/polycarbonate type with back plate suitable for battan fittings, complete all as specified and directed. |
| 110 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose compete all as specified and directed. |
| 111 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 112 | S & F for LED luminaire 600 mm x 600 mm square LED panel 35/36 watts, 220V recessed type with high efficieny PMMA diffuser soft glare free light complete with drovers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specefied and directed. |
| 113 | S&F energy saving environmental friendly and robust , open type vertical highbay long life, exclusive innovative die-cast aluminium IP 65/66 industrial light with high power COB LEDs as light source, suitable for highlighting retails space 100 watt LED replacement metal halide industrial light luminarie complete with all accessories, connecting up with twin core twisted flexible copper conductor cable all as specified and directed. |
| 114 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed.Note :- Four runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 6 Sqmm cable, one run ( with Green colour for Earth) of 6 Sqmm cable and one run of PVC conduit will be measured as one unit. |
| 115 | M&L sub main wiring (concealed type) in & including PVC Rigid Conduit of suitable size with two single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having stranded copper conductor of 06 sqmm nominal cross sectional area each drawn into and all accessories including one single core 6.00 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified and as directed. Note : Two run single core cable(1 x 6 Sqmm single core cable of Red/Yellow/Blue colour for Phase + 1 x 6 Sqmm single core cable Black colour for Nutral), 1 x 6 Sqmm single core cable Green colour for earth conductor and one run of PVC conduit shall be measured as a unit length. |
| 116 | S&F TPN enclosure with 3P+N+E plug and socket complete with and including one four pole MCB 63 A, 415 volt,IK-08, including necessary provision for inserting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directedcomplete all as specified and as directed. |
| 117 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one double pole MCB 20 A, 10 KA 240 volt complete all as specified and as directed. |
| 118 | M & L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incomming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer with with minimum dimensions (1.2 x 1.0 x 30 cm ) flush to wall for incorporating 02 No TPN DB including dander notice board etc,including taking out old TPN DB and re-fixing on site complete all as specified and as directed. |
| 119 | M & L for shifting of busbar box from inside room to out side of the wall with comlete wiring and cable shifting including 40mm GI Pipe, lugs, nut bolts, suitable clamps, wshers, one coat of 1st grade quality of synthetic white enamelled paint by spraying etc complete all as specified and as directed by Engr - in - Charge. |
| 120 | M&L for taking down exhaust fan/wall fan of any sweep, any type and refix on old location after repair including one coat of 1st grade quality of synthetic white enamelled paint by spraying including preparation of old painted surface to remove all dust, oil mark etc and filling cavaties with filler materials, before painting, complete writing the MES numbers on exhaust fan with black synthetic enamel paint of 1st grade quality by stenciling with uniform size of letters/of figures n.exc 20 mm in height letters/figures to be written in each fan complete all as spedified and directed. |
| 121 | Schedule of credit amount of Rs 35,118.00 to be deducted during AOC. Please Enable Macros to View BoQ information |