| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur NAME OF WORK : REPAIR TO ROOF TREATMENT, RETROFITTING AND ASSOCIATED WORK IN ZONE-II AREA UNDER AGE B/R-II OF GE (I) KANPUR Contract No : GE(I)/KAN/T-49 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of terracing tiles/brick tiles single layer on roof,laid bedded and pointed in any mortar complete all as specified and directed. |
| 3 | Demolition of cement concrete of any description as in roofs, floors (other than ground floor) and similar suspended works complete all as specified and directed. |
| 4 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone agg) as in padding top surfaces to be finished even & smooth without using extra cement complete all as specified and directed. |
| 5 | Rendering 10 mm thick in CM 1:3 finished even & smooth using liquid water proofing compound @ 200 Ml/50 Kg of cement over RCC roof padding etc complete all as specified and directed. |
| 6 | Supply only liquid water proofing compound complete all as specified and directed. |
| 7 | Preparation of concrete/Plastered surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying following roof treatment complete all as directed by Engr-in-Charge :-(a) Applying bituminous primer coat conforming to IS-3384 @ 0.4 Kg/Sqm cover prepared surface till the surface is properly impregnated and insolvent oil primer shall be allowed to evaporate completely.(b) Applying water proofing treatment by using APP polymembrane mineral finished over roof and including vertical surfaces and providing APP membrane having non woven polyster film reinforcement with 3 mm thick and weight not less than 3.00 kg/sqm and finished on top with mineral/slate finished laid with 100 mm & 150 mm over lap on side & end laps respectively complete all as per manfucturer's instruction. The membrane has to be laid with LPG torch and overlap sealed and finished neat. All joint and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @ of 200ml/Bag of cement and curved before laying membrane and including applying two coats of bituminous aluminium paint over membrane surface complete all as specificed and directed. |
| 8 | Removing of demolished meterial to a distance of exc 100m and n exc 1000m or under, beyond the lead included in the rates, including loading, unloading complete all as specified and directed |
| 9 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed. |
| 11 | M&L for preparation of new steel or iron surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat zink chrome red oxide primer complete all as specified and directed. |
| 12 | S&F in for mild steel bolt machine made with hexagonal or square heads at one end and screw the other to be fitted with washer etc and one hexagonal or square not exc 5cm long end dia of neck 12mm including taking out old unserviceable bolts with nuts and washers complete all as specified and directed. |
| 13 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. |
| 14 | S&F of Pre- painted galvalume aluminum zinc coating GI based corrugated profile sheet TCT with gsm -150 sheet 0.50mm thick of any colour total mass coating 150gms/sqm (both side) and having tensile strength of 550 Mpa as in roof covering/cladding to wall/window chajja, fixed with self tapping screws complete all as specified and directed. |
| 15 | S&F of Pre- painted galvalume aluminum zinc coating GI based plain profile sheet TCT with gsm -150 sheet 0.50mm thick of any colour total mass coating 150gms/sqm (both side) and having tensile strength of 550 Mpa as in roof covering/cladding to wall/window chajja, fixed with self tapping screws complete all as specified and directed. |
| 16 | Dismantiling of loose concrete by chiselling from RCC members like col, beam, parapet, facia, ceiling and also remove any existing treatment on RCC surface by rubbing, scrapping etc exposing the reinforcement without disturbing the reinforcement and get free from rust by sand blasting providing at places addl reinforcement welding with existing reiforcement as directed wherever required binding with welded mesh 100 mmx100mm (12 gauge welded mesh) & tack welding and primed with using Araldite epoxy resins ( manufactured by M/s Ciba Geigy Ltd/ FAIR BOND EP/Sika or other approved manufacture) & provision of guniting pressure 2 to 3 Kg/Sqm with admixer 1 cement 3 sand mixed Dr fixit Pidicrete SC plasticiser (2 to 10% by weight of cement) of thickness 40mm average including stripping, floating with wooden strippers for proper dimension control inclusing necessary form work & scaffolding up to Three storey complete and surface of guniting to be finished fair and even with and including 10 mm thick plaster in cement mortar 1:4 with water proffing compound @3% by weight of cement, cleaning & removing of waste material etc as directed at site including necessary painting,white wash, distemper/ exterior acrylic emulsion).All surrounding wall, joineries and fitting should be covered with polythene sheet by contractor while work. (Any wall, floor,fittings and roof damaged by the contractor shall be repaired/change by contractor under same item and no extra payment will be paid to contractor on this account complete all as specified and directed. Note: Welded mesh & addl reinforcement if required measured and paid separately. |
| 17 | M&L for grouting using polymer modified waterproof grout.The detail procedure of inject grouting is as under:(i) Drilling of 12mm dia holes upto 40mm depth and provide PVC nozzles/ entry ports over grid@ 1m c/c or less depending upon situation.(ii) Before injecting the grout compressed air to be blown to remove all dist and dirt.(iii) Grouting atpressure of 5kg/sqcm to be don till refusal/ rejection or appearance of grout from adjacent nozzle.(iv) Observe the cracks and make V groove along.(v) Nozzles and V groove shall be filled with polymer based mortar. |
| 18 | Taking down existing sunken portion treatment by demolition of old concrete and tiles and carry out the sunken treatment as in following steps given below and as directed by the Engineer-in-charge :- (a) S&F drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) and WHB pipe 40 mm dia from bottom of WHB to Floor trap as required at site. (b) M&L PCC 1:1.5:3 type B-0 (using 12.5mm graded stone agg), 50 mm thick laid in slope towards drainage out spout pipe mixed with waterproofing chemical as per manufacturer instructions of MAKE :FOSROC/SIKA/Pidilite/STP. Khurra 150mmx150mm (min) at appropriate location for free flow (of leaked water if any) towards drainage spouts shall be provided integrally while laying PCC.Fixing of spout shall be done with same PCC as in this item. (c) M&L18 mm thick cement platster in CM 1:3 on vertical faces mixed with water proofing chemical of MAKE : 301 Pidicrete URP of Dr Fixit or other techno commercially Equivalent make of SIKA/ Pidilite/FOSROC/STP (d) Item no 94 (c) shall be executed while concrete is green as per item no 94(b) above and proper curing and ponding test shall be done before laying drainage/water supply pipes upto the entire satisfaction of Engineer in charge. (e) Applying two coats of SIKA TOP seal 107 of SIKA or other techno commercially Equivalent make of FOSROC /Pidilite/Dr Fixit/STP on vertical as well as horizontal surface. (f) Drainage and water supply pipe if required & test for leakage/sanitary pipes and shall be laid to slope and a clear gap underneath the pipes shall be made available by providing suitable cement concrete blocks. (g) M&L PCC 1:5:10 type E-2 using 10-40 mm down graded stone aggregate as reqd depth at site over and including 150mm thick 20mm single sized stone aggregate to provide a filter media. (h) M&L PCC 25 mm thick 1:2:4 type B0 using 12.5 mm grade stone aggregate as level course. (j) M&L for 7 to 8 mm thick non skid ceramic coloured tiles (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed filled with epoxy chemical make: SIKA/FOSROC/PIDILITE/ Dr Fixit/STP.mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM (1:6). |
| 19 | Note : (i) Waterproofing Treatment shall be undertaken alongwith laying of drainage pipes/Sanitary pipes/ Drainage Spout etc. (ii) The work shall be carried out as per the direction of Engineer in Charge. (iii) The sunken treatment work shall only be carried out after written approval of Engineer in charge for Leakage/seepage of water/sanitary pipes. (iv) Cost of drainage spout, sanitary pipe incl cast iron pipe and fiitings shall deemed to be included in the item.(v) Laying of Chemical required for varios applications shall be as per manufacturer instructions. (vi) Plan area shall only be measured and paid. (vii) The contractor shall give a guarantee of 10 years from the date of completion of work for sunken treatment. The amount Rs. 25.00 (Rupees Twenty five Only) per Sqm and min of Rs 2500/- for sunken treatment shall be with held from contractor’s final bill till the expiry of guarantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE (I) Kanpur. |
| 20 | M&L for Mild steel TMT bar 6 mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally, binding wire (0.9mm dia annealed) for rebaring complete all as specified and directed. |
| 21 | S&F for Welded steel wire fabric weight n exc 2 Kg/sqm complete all as specified and directed. |
| 22 | Demolition of reinforcement cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 23 | M&L for Nominal mix Type B0 (1:1.5:3) 12.5mm aggregate as in slabs supported on walls, beams and columns in floors,chajjas, balconies, canopies, deck slabs and in shelves blocks etc and the like complete all as specified and directed. |
| 24 | S&F Formwork to side and soffits of floor and roof beam, beam haunching, girders, bressumers, lintels, cantilevers, shelves including supports, overhang,chajjas etc. also splays between floor and roof beam etc. for flat rough finished surface of concrete complete all as specified and directed. |
| 25 | M&L for Mild steel TMT bars 05 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binder and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 26 | Demolition of brick work or stone/boulders masanory built in cement mortar including all quoins, arches, pillars etc, but excluding ashler facing, dressed stone work and precast concrete articals complete all as specified and directed. |
| 27 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in built in cement mortar 1:6 complete all as specified and directed. |
| 28 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in built in cement mortar 1:6 (except bricks i.e. by using old bricks after proper cleaning) complete all as specified and directed. |
| 29 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 30 | Taking down cement plaster on wall & ceiling including raking out joint, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 31 | M&L for 15mm thick rendering of brick wall in CM 1:6 finished even & fair on other than fair faces up to ceiling hieght including required scafolding etc complete all as specified and directed. |
| 32 | M&L for 15mm thick rendering on fair faces of brick wall in CM 1:4 finished even & fair with using WPC up to G+2 hieght including required scafolding etc complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 33 | M&L for 10 mm thick cement plaster on ceiling in CM 1:3 finished even and smooth without using extra cement including required scafolding complete all as specified and directed. |
| 34 | M&L for preparation of newly plastered surfaces of ceiling applying two coats of oil bound distemper over and including a coat of primer complete all as specified and directed. |
| 35 | M&L preparation of new surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 36 | M&L for 1mm thick wall care putty on wall and ceilings complete all as specified and directed. |
| 37 | M&L for preparation of newly plastered surfaces of wall and Applying two coat of cement based paint over and including one coat of primer on wall with roller/ brush including initial and final curing on wall complete all as specified and directed. |
| 38 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 39 | M/L for preparation of newly plastered surface of walls and applying two coat of oil emulsion distemper/ acrylic washable distemper over and including a coat of primer complete all as specified and directed. |
| 40 | M&L for preparation of newly plastered surfaces of walls applying two coats of exterior weather proof anti algae 100% acrylic emulsion over and including a coat of exterior water based primer complete all as specified and directed. |
| 41 | Supplying and Applying, two components acrylic polymer modified cementitious coating on new masonry surfaces devoid of plaster, with Hydrostatic resistance upto 5 bars with forced coverage of 1.75 Kg per Sqm in two coats using roller or brush with a gap of 4 to 6 hrs between the coats. The coats to be applied shall be perpendicular to each other complete all as specified and directed.Note : The Coverage is to be strictly maintained for film formation. |
| 42 | Taking up or down steel tubing and connections of 15 mm bore including fittings of any type and material complete all as specified and directed. |
| 43 | Taking up or down 20 mm dia steel tubing and connection including removal of fittings of any type and material complete and all as specified and directed. |
| 44 | Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring. etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed. |
| 45 | Supplying and laying of 20 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11with all fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 46 | S&F GI steel tubing 20mm bore medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 47 | S&F GI steel tubing 25mm bore medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete as specified and directed. |
| 48 | Dismantling PVC water tanks and remove to store capacity exc 250 Ltrs and n exc 500 Ltrs complete all as specified and directed. |
| 49 | Dismantling PVC water tanks capacity exc 250 Ltrs and n exc 500 Ltrs and refixing in the same position complete all as specified and directed. |
| 50 | S&F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including 20mm dia float valve, Cover, GI nipple of suitable size complete all as specified and directed. |
| 51 | Dismantling PVC water tanks and remove to store capacity exc 500 Ltrs and n exc 1000 Ltrs complete all as specified and directed. |
| 52 | Dismantling PVC water tanks capacity exc 500 Ltrs and n exc 1000 Ltrs and refixing in the same position complete all as specified and directed. |
| 53 | S&F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including 20mm dia float valve, Cover, GI nipple of suitable size complete all as specified and directed. |
| 54 | S&F in repair 20mm dia Gun metal globe or gate valve with iron wheel head, screwd both ends for iron pipe complete all as specified and directed. |
| 55 | S&F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 56 | M&L for Cleaning and removing all scale and dirt, etc, from tanks capacity exc 250 ltrs but n exc 500 ltrs and from mouths of circulating pipes, etc.complete all as specified and directed. |
| 57 | M&L for Disconnecting existing tanks, exc 250 & n. exc. 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisted if required reconnecting and refixing in position complete all as specified and directed. |
| 58 | M&L for Disconnecting existing tanks, exc 500 & n. exc. 1000 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisted if required reconnecting and refixing in position complete all as specified and directed. |
| 59 | S&F in repairs for vitreous china wash basin white flat back size 550x400mm but exclusive taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets or erecting stand, waste pipes upto floor trap, pedestal & brackets complete all as specified and directed. |
| 60 | S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440 mm white with integral foot rest (excluding flushing cistern ) including connection to trap and to flush pipes etc and lime concrete bedding & flush pipe complete all as specified in SSR and including S&F trap set complete all as specified and directed. |
| 61 | S&F in repair vitreous china wash down water closet pedestal pattern white with plastic seat cover and flush pipe (excluding fixing of bolt of flushing cistern ) including all fitting complete all as specified and directed. |
| 62 | S&F in repair 15mm bore bib tap long body, fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for brass ferule and fixed complete all as specified and directed. |
| 63 | S&F in repair 15mm bore bib tap two in one long body, fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for brass ferule and fixed complete all as specified and directed. |
| 64 | S&F in repairs 15mm bore stop valves,fancy type chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 65 | S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed |
| 66 | S&F 15mm bore PVC connection 600mm long heavy duty with brass fly nut and warsher for hot and cold water complete all as specified and directed. |
| 67 | S&F in repair 10 ltrs capacity low level PVC dual flushing cistern, valveless, syphonic type, white,with inlet,ball float and handle including brackets complete and all as specified and directed. |
| 68 | S&F in repair 15 mm bore, brass CP WHB mixer two in one for mixing hot and cold water screwed down for iron pipe complete all as specified and directed. |
| 69 | S&F in repair stainless steel full treaded 32mm bore waste coupling for sink/ WHB complete all as specified and directed. |
| 70 | S&F in repair standard PVC waste pipe 32mm bore for sink/ WHB complete all as specified and directed. |
| 71 | S&F in repair medium duty PVC connection pipe 18-24 inches long as required complete all as specified and directed. |
| 72 | S&F in repair health foucet ABS body with 1 mtr PVC silver foil connection pipe complete all as specified and directed. |
| 73 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 74 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.xed to wall complete all as specified and directed. |
| 75 | S&F in repairs brass chromium plated shower rose 125 mm dia with swivel joint including shower arms in suitable lengthcomplete all as specified and directed. |
| 76 | S&F in repair PVC (SWR) rain water pipes single socketed in any length with rubber ring joints 110mm bore fixed to walls PVC projected brackets and proper fixing with cement grout on terrace complete all as specified and directed. |
| 77 | S&F PVC (SWR) bends any radius 110 mm bore fixed with rain water pipe complete all as specified and directed. |
| 78 | S&F in repairs for joint free Non Skid ceramic coloured tiles (also in patches ) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.09sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. over and including 15 mm thick screeding in CM 1:6 complete all as specified and directed. |
| 79 | S&F in repairs for joint free Non Skid ceramic coloured tiles (also in patches ) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.09sqm but not exceeding 0.18 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 80 | S&F in repairs for coloured glazed ceramic tiles fixed in pattern of different colour including border of size 300x450x7 mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid over and including 10 mm thick rendering in cement mortar (1:4), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. |
| 81 | S&F in repairs for joint free Non Skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screeding in CM 1:6 complete all as specified and directed. |
| 82 | S&F in repairs for joint free Non Skid ceramic coloured tiles (also in patches ) 7 to 8mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 83 | M&L for Preparation of old decorated surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of white wash, .on any surface of walls. (note: Using necessary filling whereever required as directed by Engineer in charge.)(Note: work shall be carried out upto triple storey height of building including necessary scaffolding, T&P, safety measures etc ) |
| 84 | M&L for Preparation of old decorated surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of colour wash, on any surface of walls. (note: Using necessary filling whereever required as directed by Engineer in charge (Note: work shall be carried out upto triple storey height of building including necessary scafolding, T&P, safety measures etc ). |
| 85 | M&L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc and applying one coat of cement base paint (any colour) on wall including necessary material , labour ,T & P, scaffolding as required at site complete all as specified and as directed. |
| 86 | S&F 15 mm bore, brass CP wall mixer (2 in 1) for mixing hot and cold water including provn of overhead shower with 115mm long bend pipe, connected legs and flages including all other connected accessories screwed down for iron pipe complete all as specified and directed. |
| 87 | M&L preparation of newly plastered sufaces of roof including cleaning the surfaces by using wire brush / pressure hose and applying high performance polyurethene liquid membrane waterproofing coating cold applied in two coats @ 1.5Kg /Sqm/ 2 coats spray/ brush applied, with an elongation of 300% to 700% and tensile strength of not less than 1.5 N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging abiltity of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet, the PU coating is to be continued 150mm up the parapets or walls and 100mm into the rainwater pipes. The final coat of Polyurethane coat is to be sprinkled with a micron layer of clean sand if the roof is non-accessible type. For Accessible roof type Roof tiles to be provided.complete as per manufacturer's instructions complete all as specified and directed.Note:1. The contractor shall submit a gurantee of 10 years from the date of completion of work for waterproofing treatment alongwith manufacturer's gurantee. The amount of Rs. 40 ( Forty ) per Sqm and min of Rs. 4000/- for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against guarantee money. 2. The water proofing shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work.3. Cost of providing roof tiling will be paid under respective item. |
| 88 | S&F in repair 3 mm thick sheet glass panes any size fixed on door/ window shutters with and including beading/ putty/ rubber gasket etc. complete all as specified and directed. |
| 89 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |