| 1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with metal clamps of approved make at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints, Including for all heights, necessary support, hanging works drilling and finishing holes at wall of all height and scaffolding charges etc complete as per direction of Engineer in Charge. External work- Exposed on Wall |
| 2 | 40 mm nominal dia Pipes |
| 3 | 32 mm nominal dia Pipes |
| 4 | 25 mm nominal dia Pipes |
| 5 | 20 mm nominal dia Pipes |
| 6 | 15 mm nominal dia Pipes |
| 7 | Providing and placing on terrace (at all floor levels) polyethylene Anti bacterial water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 8 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) ball valve (brass) of approved quality as per direction of Engineer-in-charge. |
| 9 | 40mm nominal bore |
| 10 | 25mm nominal bore |
| 11 | Providing and fixing C.P. brass long body bib cock of approved quality confirming to IS standards and weighing not less than 690gms.15 mm nominal bore |
| 12 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 13 | Painting with synthetic enamel paint of approved brand and manufacturer to give an even shade: two or more coat on new work |
| 14 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 15 | 40mm nominal bore,206mm long, weighing not less than 690gms. |
| 16 | Providing and fixing cpvc tank nipple of approved quality as per direction of Engineer-in-charge. |
| 17 | Internal Signage: Providing & fixing 5 mm thick Acrylic Sheet router cut into provided size with LG SAV with Eco-Solvent print and over lamination pasted on acrylic sheet.Fixing Procedure-(a) For Wall Mounted Signage. Acrylic Sheet mount flush to architectural surface with screws as required for secure and stable mounting(b) For Hanging Signage. Stainless Steel chain/ 25mm D-clamp make perfect / equivalent brand attached with the signage.(c) For Projected Signage. Acrylic sheet fixed with Aluminium “C” channel with adjustable nuts , all complete with approved brand and quality as per the directions of Engineer-in charge . (Note-Payment will be made as per the Acrylic Sheet Signage fixing area - SQM ) |
| 18 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 19 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 20 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing andreinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 23 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 28 | Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 29 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 32 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) |
| 33 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6 mm for diagonal braces |
| 34 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 35 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 36 | Extra for concrete work in superstructure above floor V level for each four floors or part thereof. Please Enable Macros to View BoQ information |