| Sl. No. | Item Description |
| 1 | Dismantling all types of masonry excepting cement concrete, plain or reinforced, stacking serviciable materials at site and removing rubbish as directed within a lead of 75.00 metre.a) In Ground Floor including roof ground floor |
| 2 | Dismantling RC Floor, Roof, Beams etc. including cutting rods and removing rubbish as directed within a lead of 75.00 metre including stacking of steel bars.a) In Ground Floor including roof |
| 3 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof.(a) upto 150 mm. thick |
| 4 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. |
| 5 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 6 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 7 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 8 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.](i) With 1:6 cement mortar(c) 15 mm. thick plaster.For Outer walls.In ground floor. |
| 9 | In first floor. |
| 10 | (b) 20 mm. thick plasterInternal wall In ground floor. |
| 11 | In first floor. |
| 12 | (iii) With 1:4 cement mortar(c) 10 mm. thick plasterFor Ceiling Works.In ground floor. |
| 13 | In first floor. |
| 14 | Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directe |
| 15 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. |
| 16 | Labour for Chipping of concrete surface before taking up Plastering work.In ceiling, beam sides & soffit, column faces, staircase etc. |
| 17 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.River bazreei) In ground floor and foundation. |
| 18 | ii)Beyond ground floor roof up to 1st floor roof. |
| 19 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.i) In ground floor. |
| 20 | (f) 25mm. to 30mm. shuttering without staging in foundation etc. |
| 21 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 22 | (II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. VarietyIn ground floor and foundation.(A) Stone metal.(a) 6:3:1 proportion |
| 23 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bennding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor / upto 4m.(i) Tor steel/Mild steel In Ground Floor and Foundation.II)JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL |
| 24 | First floor |
| 25 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu. M. per sq.m. |
| 26 | Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor |
| 27 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. i)First floor |
| 28 | Supplying, fitting and fixing Marble Slab/Tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av0 thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in- charge in Ground floor. (White cement and Pigment to be supplied by the Agency)(a) With Makrana plain pink/ Adranga Pink/ Makrana plain pink/ Garbh Gulabi/ Udaypur Green/ Black Bhaslana.(iii) Area of each Slab/tile exceeding 0.60 sq.m but notexceeding 1.00 sq.m. |
| 29 | Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete.In ground floor(a) Area of each Granite slab upto 0.60 Square meter. |
| 30 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone. |
| 31 | Supplying, fitting & fixing best quality digital printed Ceramictiles in coloured decorative on walls and floors to match withthe existing work & 4 nos. key stones (10mm) fixed withadhesive 4.5 mm thick at the back of each tile & finishing thejoints with white cement mixed with colouring oxide ifrequired to match the colour of tiles including roughening ofconcrete surface, if necessary or by synthetic adhesive & groutmaterials etc. With polymerised adhesive and epoxy groutpointing including spacer - 2mm (When tiles are laid overexisting hard ready surface) all complete as per direction ofEngineer-in-charge.Ground floor |
| 32 | First Floor |
| 33 | Supplying and laying true to line and level Double ChargeVitrified Tiles of approved brand conforming to IS 15622:2006 (Group B I a) and tested as per IS 13630:2006 (relevantparts) [Non-modular sizes for tiles with Water Absorption (av.)≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of6mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course and jointsgrouted with admixture of white epoxy grout materials ofapproved brand including spacer -2mm as directed andremoval of wax coating of top surface of tiles with warm waterand polishing the tiles using soft and dry cloth upto mirrorfinish complete including the cost of materials,Iabour and allother incidental charges complete as per direction of Engineerin-Charge. (Note: This work should not be executed withoutspecific permission of Superintending Engineer)b) ln Ground FIoor:(size not Iess than 800mmX 800 mm X10.2 mm thick) |
| 34 | First Floor |
| 35 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C(ii) One coat on new surface.In ground floor. |
| 36 | First Floor |
| 37 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(a) Normal Acrylic EmulsionIn ground floor. |
| 38 | First Floor |
| 39 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper/Acrylic emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C(ii) One coat on new surface.Water based interior grade Acrylic primerGround floor |
| 40 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)i) Standard QualityGround floor |
| 41 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 42 | Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 43 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 44 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 45 | (b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 46 | Supplying fitting and fixing in position approved P.V.C. door frame(matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x2 mm. (+ - 0.2 mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. |
| 47 | (B)PVC Door Shutter - 30 mm thick. Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm.x 30 mm. section with 2.0 mm.(+ - 0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each othe by self tapping screws and one solid polymeric/M.S. galvanised tubular L-shaped bracket 10 mm.X 200 mm. in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm. X 30 mm. with2.0 mm.(+ -0.2 mm.) wall thickness will be placed in the middle, reinforced by solid polymer bar of 200 mm. long at both ends and screws ftrom both sides as lock rail.the section frame will then be fitted in by PVC panels of size 100 mm.X 25 mm. with wall thickness 1.2 mm.(+ -0.2 mm.) and 2 nos. of 6 mm.bright rod will be inserted horizontally with both side check and nut system and streches where fixing of hinges /hasp bolt/tower bolt/door ring are required to be strong enough to with stand wear and tear.1)In Ground floor. |
| 48 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S. clamps. (The quantity shoud be corrected upto three decimals).(d) Sal : Local.In first floor. |
| 49 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood vveneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35mm thick shutters (single leaf)In first floor. |
| 50 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. |
| 51 | (ii) Door stopper (Anodised aluminium) |
| 52 | Renewing iron mortice lock (local best approved quality) 6 lever with handle,connected rods and keys consisting a complete set:(a) With chromium plated handle. |
| 53 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(iii) 300mm x 16mm dia. bolt. |
| 54 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed withcadmium plated screws:(vii) 100 x 75 x 4.0mm. |
| 55 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(ii) 100 mm grip x 10 mm dia rod. |
| 56 | Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.(a) Heavy type (I.S.I. size 3) |
| 57 | Supplying, fitting and fixing M.S. clamp for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction.(c) 40mm. X 6mm, 125mm. Length. |
| 58 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in groundfloor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. In ground floor. |
| 59 | Spplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified color / natural) matt finished conformating to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizing filmII) Coloureda) 2- track sliding windowi) Bottom frame |
| 60 | ii) Top and side frame. |
| 61 | a) 3- track sliding windowi) Bottom frame |
| 62 | ii) Top and side frame. |
| 63 | d) Shutter for all track sliding windowi) Bottom & Top member. |
| 64 | ii) Style side member. |
| 65 | iii) Interlock member. |
| 66 | g) Fixed glazing.i) Top, bottom and side member. |
| 67 | ii) Mullion. |
| 68 | iii) Glazing clip. |
| 69 | j) Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.)k) Movable door shutter.i) Door frame. (Top & sides). |
| 70 | ii) Shutter :Top rail. |
| 71 | Bottom rail. |
| 72 | Lock rail |
| 73 | Door vertical. |
| 74 | Glazing cleap. |
| 75 | Supplying PVC rollers for sliding windows as per direction of Engineer in charge. |
| 76 | Supplying maruti lock (100mm) |
| 77 | Labour charge for fabrication and installation of composite door, window, partition made from extruded alloy aluminium sections for the following units:-(A) Glazed aluminiup sliding windows made of extruded annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and alining of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Poly Shulphate sealant and in between shutter and window frame where necessary including cutting to requisitte size and fixing glass as per drawing, specification and direction of Engineer- in charge. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleate angle etc. but excluded the cost of extruded sections, glass, neoprene / EPDM gasketing, locking arrangement and rollers.2- track sliding window1)In Ground floor. |
| 78 | 2)In First floor |
| 79 | 3- track sliding windowIn First floor |
| 80 | iv ) Fixed glazing. |
| 81 | (B) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, dhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge.For Single leaf swing doorIn 1st Floor |
| 82 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.ii) 4mm thick coloured / tinted / smoke glass. |
| 83 | iii) 5mm thick clear glass. |
| 84 | (iv) 5 mm thick coloured/tinted/smoke glass |
| 85 | 12mm thick coloured / tinted / toughened glass coforming to IS:2553-1992 (Part-II |
| 86 | 6mm thick coloured / tinted / smoke glass |
| 87 | Supplying heavy duty hydraulic double action floor spring along with toppin/set of pivots conforming to IS: 6315 or any approved make as perdirection of Engineer in charge. |
| 88 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.i) For sliding windowsb) 'U' shaped EPDM gasket for frames. |
| 89 | c) Weather gasket / Wool pile for door vertical. |
| 90 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(i) CPVC Pipes Class-1, SDR-1115 mmFor Exposed Work15mm |
| 91 | 20 mm |
| 92 | 25 mm |
| 93 | For Concealed Work15 mm |
| 94 | 20 mm |
| 95 | 25 mm |
| 96 | (a) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand). |
| 97 | e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand). |
| 98 | (d) Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).). |
| 99 | Supplying, fitting and fixing bib cock or stop cock.(c)(ii) Chromium plated Bib Cock with wall flange (Equivalent to Code No.5047 & Model - Florentine of Jaquar or similar brand). |
| 100 | (b)(i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 101 | Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 102 | Supplying, fitting & fixing chrome plated brass battery based infrared sensor oprated pillar cock , having foam flow technology. (Model: Pillar Sensor Faucet of Hindware or similar brand). [Note: This work should not be executed without specific permission of Superintending Engineer.]15 mm normal bore |
| 103 | Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. (a) Plain edge sink with overflow(i) 610 mm X 450 mm X 200 mm |
| 104 | Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) (a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 105 | Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand). |
| 106 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specificatioons with P.V.C. fittings completre, C.i. brackets including two coats of painting to bracket etc. |
| 107 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iii) 600 mm long |
| 108 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(ii) 750 mm long |
| 109 | (f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 110 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets(ii) 630 mm X 550 mm X 180 mm |
| 111 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.ii) C. P. Flush Pipe |
| 112 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.(i) 450 mm X 300 mm |
| 113 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only)a) 40 mm. dia. |
| 114 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer1000 litre capacity |
| 115 | Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L. |
| 116 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 117 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. |
| 118 | B) UPVC Fittings: For Exposed Work ( Rain water Pipes ).a) Plain Tee, 110 mm dia |
| 119 | b) Plain Y, 110 mm dia |
| 120 | c) Bend 87.5 degree, 110 mm dia |
| 121 | d) Shoe, 110 mm dia |
| 122 | Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labour according to satisfaction of the Engineer - in - Charge |
| 123 | Taking out old damaged tarfelt from the roof, parapet etc.preparing the roof surfaces by removing all spoils, blisters,moss etc. from the working site and disposal of the samebeyond the compound and cleaning the site in all respect asper direction of Engineer-in-Charge. |
| 124 | Screed concrete on roof with cement concrete (4:2:1) including admixture of damp proof materials as per manufacturers specification laid in panels as directed including cleaning, chipping and applying cement sluury @ 1.75 Kg/SqM. Providing ghoondies at junctions with parapet etc. shapping and finishing at mouths of rainwater pipes complete with top finishing with cement punning not more than 1.5mm thick , curing complete as per direction of Engineer-in-charge.[Artificial Stone Flooring (Sl. no. 3 at Page no. 41) minus Neat Cement Punning (Sl.15 at Page no. 192)= Rs. 344.00 - Rs. 34.00 = 310.00].Average 35 MM thick. |
| 125 | Application of priming coat for standard bituminous waterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S. 1346 - 1991 & 3384 - 1986 applied @ 0.27 Liters /Sq.m. over clean and prepared roof surface complete as per satisfaction of theEngineer - in - Charge. |
| 126 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage,complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) (Ref: Sl. No. 97 of (U) Additional Items, Page no. 302 of PWDSOR for Building works w.e.f. 01.12.2015) |
| 127 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(b) With 'S' trap |
| 128 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (b) Anglo Indian(ii) Plastic (hallow type) white |
| 129 | Supplying, fitting and fixing towel rail with two brackets.(b) Aluminium.(i) 25 mm. dia. and 450 mm. long. |
| 130 | Supplying, fitting and fixing Tooth brush and Tumbler holder of approved make of size 140 mm X 65 mm (porcelain). |
| 131 | Supplying, fitting and fixing liquid soap container.(a) Cromium plated. |
| 132 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20 mm. thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15 mm. thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm. thick cement plaster (1:4) on the top the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm. to 63 mm. size including R.C.C. cover slab of 100 mm.thick with cement concrete (1:1.5:3) with stone chips with necessary reinforcements and shuttering including one 560 mm. dia. R.C..C. manhole cover (heavy type) of approved make supplied, fitted and fixed in the cover slab with necessary fitings, making necessary arrangementsfor pipe conections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm. thick dry brick work and 250 mm. thick cement brick work (6:1) and 1.00m. Inside dia. |
| 133 | Constructing inspection pit of inside measurement 600 mm. X 600 mm. X upto 600 mm. (depth) with 250 mm. thick 1st class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm. thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling , 15 mm. thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm. thick (1:4) cement plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm. thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm. thick cement plaster (1:4) in all external surface of the slab and one 560 mm. dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.ii) With Bazree. |
| 134 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) |
| 135 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I.intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc.complete)In ground floor |
| 136 | Supplying, Fabrication, Erection on suitable RCCfoundation and Commissioning with 3 (three) months TrialRun (including cost of routine testing of water sample rperformance evaluation) of pressure type Iron removalplant as per design norms of the P.H.E. Dte. with necessaryaccessories viz. MS fabricated shell with minimum 10 mmthick MS plate with 2 (two) coats of anticorrosive paint &minimum 12 mm thick MS media supporting plate fittedwith required no. of pot strainer, MS fabricated xidationchamber with minimum 10 mm thick plate with necessarypipe connection, valves, Gauges & other instruments asrequired as per departmental approved design & drawingincluding cost of filter media, Air Compressor & Air blowerwith motor, starter, main switch etc. of required capacity &approved specification including power connection frommain line etc. all complete.Rate excludes the cost of Concrete Platform & drain, and the cost of Blower Room For more than 50 cum/hr, twin unit of equal size in parallel shall be adopted.10 cum/hr |
| 137 | Supplying, fitting and fixing glass reinforced polyester translucent fiber glass sheet to match with GCI Corrugation as per IS: 12866 - 1989 in roof fitted and fixed with 10 mm dia \\"J\\" or \\"L\\" hook, bolts and nuts, limpet and bitumen washers and putty with 150mm end lap and one corrugation minimum side lap complete.a) 1.6mm +/- 0.2 mm thick sheet.(2.6Kg/Sq.m)i) Natural white or tinted blue colour |
| 138 | Supplying, fitting and fixing glass reinforced polyestertranslucent ridging 450 mm long each way as per IS 2866 -1989 fitted and fixed with bolts J hooked screws and bitumenwashers complete.a) 1.6mm +/- 0.2 mm thick sheet.(2.6Kg/Sq.m)i) Natural white or tinted blue colour |
| 139 | Supplying and laying in the specified pattern of interlocking concrete Block Pavement(ICBP) with concrete blocks (with concrete grade as specified as per table 1 of IS 15658:2006) manufactured from BIS licence manufacturer, with spacer nib (Small protruding profiles on the vertical face of paver block used as a device for keeping minium joint gap in between the paving blocks as per CL no. 3.26of IS:15658 ) and a specificied size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per C.L. No. 3.3 of IS:15658) as per Table 2 of IS:15658 with flexural strength / breaking load as per Annexure G of IS :15658, on the prepared base course of specifed CBR as per table 1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filling sand will be as per clause 6.5.2 of IRC SP63) and completing the edges with cut blocks as per CL NO. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand , compaction levelling and filling up of the edge gap.50mm thick (COLOURED DECORATIVE) |
| 140 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge.Weight of Strainless Steel railing per metre 6.5 Kg (approx) |
| 141 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. (Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m |
| 142 | Supplying and laying true to line and level 20 mm / 25 mm.thick precast roof tiles made of cement conc. with stone chipsas per approved strength and density set in 25mm avg. thickcement morter(1:3) and filling up joint (3 mm wide) withcement sand mortar (1:1) applying cement slurry @ 1.75 kgper Sq.m back of tiles and then settting close the precasttiles, finishing up the joints with slurry already laid andfinally finishing the top surface including providing 150 mm.high skirting with the same tiles flushed with the insidesurface of parapet wall,finishing the mouth of rain waterpipes, curving etc. as necessary complete as per direction ofthe Engineer-in-charge. (Levelling if necessary may be paidseparately)b) For 25 mm. thick precast tiles (cement 14.6 kg/ Sq.m forunderlayer)first floor roof |
| 143 | Supplying& laying 20 mm designer chequered tiles of anyshade and of approved quality as per IS: 1237: 1980 laid inpatterns as directed in pavement, footpath including necessaryunderlay 25 mm thick average cement mortar (1:3) completein all respect with all labour and materials [using cementslurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar &slurry will be supplied by the Department. Border concrete ifnecessary to be paid separately]. |
| 144 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval anddirection of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] (i) 6mm |
| 145 | (i) 9mm |
| 146 | (i) 12mm |
| 147 | (i) 16mm |
| 148 | (i) 19mm |
| 149 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same onParticle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. ii) Thickness of laminate 1.5 mm |
| 150 | ii) Thickness of laminate 1 mm |
| 151 | French polishing to wood work including preparing surface (ordinarygloss) a) On new wood work |
| 152 | Providing and fixing of factory made uPVC Sliding window (White Colour)complete, (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be providedincluding touch lock and rollers & proper drainage system shall be provided. Window frame will be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-In-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable)c) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half ofwidth of window) window frame of size 122 x 54 mm & Sash of size 64 x 47 mmboth having wall thickness of 2.3 ± 0.2 mm |
| 153 | Providing and fixing of factory made uPVC Louver window (White Colour) (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprisingof uPVC multi-chambered with wall thickness of 2.3mm (±0.2 mm ) duly reinforced with 1.6 mm (±0.2 mm) thick G. I. Section made from roll forming process of required length (shape & size according to uPVC profile). Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (ifrequired) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. Both vertical sides of the frame, adjustable louver mechanism having one lever shall be fitted with the provision of 4 mm glass. Window frame will be fixed to the wall with 100mm long and 8mmdia for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant overbacker rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-in-Charge. (Note: Profilemanufacturer & Window Manufacturer must be one & same, Onlymanufacturer Waranty is aceptable)a) Louver Window with provision of Exhaust Fan frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm both having wall thickness of 2.3 ± 0.2 mm |
| 154 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen [ 4 way Legrand ] |
| 155 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionSPN 6A To 32 Amps |
| 156 | TPN 63 Amps. |
| 157 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 158 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 159 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works2 Module |
| 160 | 8 Module |
| 161 | 12 Module 2 Row |
| 162 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 163 | Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 164 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 165 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 166 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building worksSupplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building worksAverage run 8 mtr |
| 167 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 168 | Supply and Fixing of Celling Fan & complete Connection with PVC Cable. [ USHA / Havells / Orient ] |
| 169 | Earthing with 65 mm dia GI pipe x 3.0 Mts.long and 1 No. 40 mm x 6 mm galvanized strip (4 Mts. long), with necessary connections. |
| 170 | Supply & Fixing of 2 feet x 2 feet Office Panel L.E.D. Light Surface Type 34 Watt. [ Havells ] |
| 171 | Supply & Fixing 8\\" x 8\\" Ceiling L.E.D. Light Conceal Type 10 Watt. [ Havells ] |
| 172 | Supply & Fixing L.E.D. Flood Light for Street Light 100 Watt. [ Havells / 24x7 / Cromton ] |
| 173 | Fixing of TPN Connector Box for Tubular Pole and necessary cable connections with copper sockets. |
| 174 | Supply & Fixing of Get Light with Necessary Connections. |
| 175 | Supply and Fixing of Desk Top Computer with Colour Printer. |
| 176 | Supply & Fixing of Air Condition Machin 1 Ton with necessary connections [ Samsung , Hair, LG., Blue Star] |
| 177 | Supply & Fixing of Air Condition Machin 1.5 Ton with necessary connections [ Samsung , Hair, LG., Blue Star ] |
| 178 | Supply & Fixing of Gyeser 5 Leter Capacity with 3 Pin Top. [ Havells, Usha, Crompton , IFB ] |
| 179 | Supply & Fixing of Smart T.V. 125 cm 4k vista ultra HD |
| 180 | Supply & Fixing of CCTV, 12 slot DBR with 6 Nos. Outdoor Night vission Dom with nwcessary 270 mtr. Cable |
| 181 | Bed as per the room interior. |
| 182 | Mattress - SINGLE |
| 183 | Mattress- QUEEN |
| 184 | Dinning Table as per the room interior. |
| 185 | Dinning Chair as per the room interior. |
| 186 | Chair with cushion |
| 187 | Center table |
| 188 | 3 Seater Sofa as per the room interior. |
| 189 | Coffee Table as per the room interior. |
| 190 | Bed Side Table as per the room interior. |
| 191 | TV - 43 Inch |
| 192 | TV - 55 Inch |
| 193 | Window Curtain (Door & Window) as per the room interior. |
| 194 | Crockery |
| 195 | Linen |
| 196 | Refriegerator |
| 197 | Cooking & Home Appliances Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail