| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches in hard soil or gravelly soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. |
| 2 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge. |
| 3 | Filling in foundation trenches and plinth with excavated earth well watered and rammed in layers not exceeding 23 c.m in depth including all lead and lift, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer- in- charge. |
| 4 | Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and taxes of all Materials, cost of all Labour,Sundries, T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. (Measurement will be taken on finished compacted section only.) |
| 5 | Providing and Laying Plain Cement Concrete of proportion (1:3:6) in foundation and floors (i.e. below the base course of the flooring) using 40 mm size crusher broken H.G Stone Metal free from weathered skins , cement and screened & washed sharp river sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layer including cost, conveyance , loading,unloading, stacking ,royalties and taxes of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of the water pump required for the work etc complete in all respect as directed by the Engineer-in-charge. |
| 6 | Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in Foundation & Plinth of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 7 | Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 8 | Ground Floor |
| 9 | First Floor |
| 10 | Terrace Floor |
| 11 | Providing Fly Ash brick masonry using Fly Ash bricks of size 23 c.m. x 11 c.m. x 8 c.m.having crushing strength not less than 75 kg per square c.m in cement mortar of mix (1:4) (for half brick masonry wall) with provision of 2 nos of 6mm. dia M.S. Round Reinforcement bars at each 4th layers) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth, basement and for ornamental flower beds, plinth moulding and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials ,cost of all labour, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 12 | Ground Floor |
| 13 | First Floor |
| 14 | Terrace Floor |
| 15 | Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-250 grade , as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P |
| 16 | Required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge. |
| 17 | Foundation |
| 18 | Plinth beam |
| 19 | Column in Superstructure |
| 20 | Ground Floor |
| 21 | First floor |
| 22 | Terrace Floor |
| 23 | LINTELS |
| 24 | Ground Floor |
| 25 | First floor |
| 26 | CHAJJA AND SILL PROJECTION |
| 27 | Ground Floor |
| 28 | First Floor |
| 29 | Terrace Floor |
| 30 | FLOOR BEAM |
| 31 | Ground Floor |
| 32 | First Floor |
| 33 | Terrace Floor |
| 34 | STAIRCASES |
| 35 | Ground Floor |
| 36 | First Floor |
| 37 | ROOFSLAB |
| 38 | Ground Floor |
| 39 | First Floor |
| 40 | Terrace Floor |
| 41 | Cutting, Straightening coiled or bent up HYSD / TMT Reinforcement Bars of Fe 500 welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing Fan Hooks where necessary and hoisting, lowering and placing the same in proper position according to the approved designs and drawings in all floors at all height including cost, coveyance, loading, unloading ,stacking & taxes of HYSD/ TMT Reinforcement Bars and Binding Wires of 18 to 20 Gauge as required for the work , cost of all Labour ,Sundries, T&P,Staging and Scaffolding complete in all respect as directed by Engineer-in-charge. (Payment will be made according to the actual / proper weight of the HYSD / TMT Reinforcement Bars & Binding Wires consumed in the particular work only) . |
| 42 | Ground Floor |
| 43 | First Floor |
| 44 | Terrace |
| 45 | 16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the rough surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. as directed by the Engineer- in -charge. |
| 46 | Ground Floor |
| 47 | First Floor |
| 48 | Terrace |
| 49 | 12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. as directed by the Engineer- in -charge. |
| 50 | Ground Floor |
| 51 | First Floor |
| 52 | Terrace |
| 53 | 6 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and taxes of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge |
| 54 | Ground Floor |
| 55 | First Floor |
| 56 | Terrace |
| 57 | 25 mm. thick Grading Concrete of proportion (1:2:2) on top of the Roof Slab using approved quality of cement, 6 mm. size hard crusher broken granite stone chips with screened & washed sharp sand for mortar of approved quality from approved quarry, washed & cleaned, free from all debrises and silt along with providing a layer of waterproofing treatment by using pedicrete (URP/SBR) Latex before grading concret (Mix - Latex @ 0.54 Ltr/Sqm & Cement @ 0.008Qntl /Sqm) including hoisting, lowering and laying concrete in all floors at all height after chipping, chiseling and cleaning the entire roof surface by using wire brush, finished smooth to proper required slope and gradient including cost, conveyance, royalties, loading, unloading,stacking and taxes of all Materials, cost of all Labour, T &P, Sundries, Watering ,Curing etc.required for the work complete in all respect as directed by the Engineer-in-charge.(sika/pidilite/equivalent) |
| 58 | Grading of portico top. |
| 59 | Grading of building top & head room top |
| 60 | Providing Chequered Tile Flooring using Chequered Tile (25mm thick) of approved quality, colour and size in floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar ,grouted with neat cement slurry joining the Ultra Designer Tile with neat cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Ultra Designer Tile if required (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering, Curing for required days, including rubbing and wax polishing etc. complete in all respect as directed by the Engineer-in-charge. |
| 61 | Ground Floor |
| 62 | Providing , Fitting & Fixing Anti-Skid Ceramic Floor Tiles in flooring using special plain / printed series Anti-Skid Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 300 m.m x 300 m.m OR 400 m.m x400 m.m) confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the Anti-Skid Ceramic FloorTiles with neat white cement slurry,mixed with required (Tiles are to be immersed in the water for required time before use) quantities of pigments of approved marks to match the shades of the Anti-Skid Ceramic FloorTiles if required including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge. |
| 63 | Ground Floor |
| 64 | First Floor |
| 65 | Supplying, Fitting & Fixing Ceramic Glazed Wall Tiles in Dados Skirting and Riser of Steps using approved shade,quality and size of Ceramic Glazed Wall Tiles (having thickness of 6.5 mm to 6.7 mm & 300 mm X450.mmsize) confirming to IS.13753 in proper position in all floors at all heights on 12 mm. thick cement plaster (1:3) using screened and washed sharp river sand for mortar with cement, grounted with neat cement slurry and jointed with neat cement mixed with required approved shade of pigment to match the shade of the Ceramic Glazed Wall Tiles (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, Curing, Sundries and T&P, etc. required for the work complete as directed by the Engineer-in-charge. |
| 66 | Ground Floor |
| 67 | First Floor |
| 68 | Providing, Fitting and Fixing minimum 8 m.m to 10 m.m thick double charge Vitrified Tile in flooring using vitri Tile in flooring using vitrified Tile of approved quality, colour and size (600 mmx 600 mm coloured printed series homogeneous) in floors , treads on steps landings in all floors at all height on 25 m.m thick bed of cement mortar of mix(1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Vitrified Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Vitrified Tile if required (Tile are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials , cost of all Labour , sundries, T&P required for the work, Watering, Curing for required days including cleaning the flooring space. |
| 69 | Ground Floor |
| 70 | First Floor |
| 71 | Providing, Fitting & Fixing of 8 mm. to 10mm. thick Vitrified Tile (of size 600mm.x600mm.) of approved make confirming to specifications having minimum breaking strength 1400 kg/sq.cm in dados skirting and riser of steps in all floors at all height on 12m.m thick cement mortar (1:3) to proper slope , line and level including cutting to required size and shape ,fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-charge. |
| 72 | Ground Floor |
| 73 | First Floor |
| 74 | 12 m.m thick cement plaster with cement mortar of mix(1:4) in all floors using approved quality of cement , screened &washed sharp river sand for motar , with neat cement punning finished smooth to the brick walls in dados skirting after racking out the joints property including cost,conveyance,loading,unloading,stacking,royalties and taxes of all materials, cost of all labour,sundries T&P, scaffolding,watering,curing required for the work etc.complete in all respect as directed by the Engineer-in charge. |
| 75 | Ground Floor |
| 76 | Providing and fixing factory made single extruded WPC wood polymer composite doors , windows and other frame with high dencity rigid solid wood polymer composite of 0.7DWPC foam sheet ,mitre cut at two corners abd joined and the two vertical door profile are to be reinforced to horizontal member .The door frame shall be fixed to the wall using 6nos 150mm long M.S holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer -in -charge. |
| 77 | Ground Floor size(125mmx65mm) |
| 78 | First Floor size(125mmx65mm) |
| 79 | Ground Floor size(75mmx50mm) in toilet |
| 80 | First Floor size(75mmx50mm) in toilet |
| 81 | Head room size(125mmx65mm) |
| 82 | Supply and fixing doors as per drawing with WPC solid 3layer and ISI marked door shutter of 30 mm thick single shutter with bond wood solid block board type of 0.7 D WPC sheet incluiding cost of convinience to site of WPC shutter incluiding supplying and fixing cost of ISI mark alluminium fixtures of 3 nos. butt hinges ( IS: 205) 150 mm long , one number of aldrop ( IS: 2681) 300 mm long, one number of tower bolt (IS: 204) of 200 mm x 10 mm dia at top , two numbers 150 mm long handles ( IS : 208) , one number door stoper and one number rubber / nylon door stop bushes incluiding fixing the fixtures to doors with required number of screws, bolt and nuts incluiding labour charges for fixing the frame in position, fixing the shutter to the frame etc. incluiding over head and contractor profit . |
| 83 | Ground Floor |
| 84 | First Floor |
| 85 | Head room |
| 86 | Providing, fitting, fixing UPVC door( openable type) including providing stainless steel hinges, locking arrangement and other requisite fittings and fixtures including cost, coveyance, loading, unloading and taxes of all materials,cost of all labour,scaffolding, staging, sundries and T&P required for the works etc. complete in all respect as per approved drawing,design & specification and as directed by the Engineer-in-charge all complete. (Fenest/ Wintek make). |
| 87 | Ground Floor |
| 88 | First Floor |
| 89 | Providing, fitting, fixing UPVC windows( sliding type) including providing stainless steel hinges, locking arrangement and other requisite fittings and fixtures including cost, coveyance, loading, unloading and taxes of all materials,cost of all labour,scaffolding, staging, sundries and T&P required for the works etc. complete in all respect as per approved drawing,design & specification and as directed by the Engineer-in-charge all complete. (Fenest/ Wintek make). |
| 90 | Ground Floor |
| 91 | First Floor |
| 92 | Supplying , fitting and fixing of unplasticised poly vinyle chloride ( UPVC ) (FENESTA/ VEKA LTD) ventilator top hang 60 series duly manufactured using upvc reinforced profile of 60 mm x 55 mm x 2.5 mm outer frames, 75 mm x 60 mm x 2.25 mm for casement window sash profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised upto 50 micrones of minimum thickness of 1.5 mm prefabricated and welded so through fusion welding the window sash shall be fitted with 6 mm thick clear toffen glass of saint Gobain make duly fixed with EPDM weathering seal resistance accessories like cliping locking system made of alluminium one number per set shases and the system is to be instalised at the site using anchoring fastner silicon rubber sealant, easy glazing/ deglazing at the site incluiding cost of convinience of all materials, accessories, labour charges , materials and product conferming to ASDM D 638-14, EN-477-95 and other applicable codes and standards. |
| 93 | Ground Floor |
| 94 | First Floor |
| 95 | Supplying, Fitting and Fixing of Stainless Steel of 304 grade in Handrail using 50mm dia of 2mm thick circular pipe with stainless steel balustrade of size 32 m.m x 32 m.m x 2 m.m @ 0.90mtr.centre to centre and stainless steel square pipe bracing of size 32m.m x 32m.m x 2m.m in 3 (Three) rows in stair case and at required places as per approved Drawings, Design and Specification,welding, buffing, polishing etc with cost, conveyance,loading,unloading ,stacking & taxes of all materials,cost of all labour, T&P etc. required for the work complete in all respect in all floors at all height as directed by the Engineer-in charge |
| 96 | Ground Floor |
| 97 | First Floor |
| 98 | Supplying, Fitting and Fixing Stainless Steel 304 Grade of approved designs made out of steel bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Massonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Massonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.( Weight to be taken properly prior to fixing the grills in the works and payment to be made accordingly ) |
| 99 | Ground Floor |
| 100 | First Floor |
| 101 | Terrace Floor |
| 102 | Painting 2(two) or more coats with premium quality weather coat(weather shield max ) of approved Brand/Quality & colour on the finished external plasterd surface using required quantities of paint by the concerned manufacturer to give an even shade over a coat of primer in all floors at all height, watering the surface before applying the Weather Coat paint and curing for the required period including cost , onveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-charge. |
| 103 | Ground Floor |
| 104 | First Floor |
| 105 | Terrace Floor |
| 106 | Finishing surface of interior walls with premium quality interior acrrylic emulsion paint over a coat of wall priming of approved make and finished smooth & even surface with two coats of wall putty to receive painting in all floors at all height including cost, coveyance, loading , unloading ,stacking and taxes of all Materials, cost of all Labour, Sundries ,Scafffolding ,Staging and T&P etc. required for the work complete in all respect as directed by the Engineer-in-charge. |
| 107 | Ground Floor |
| 108 | First Floor |
| 109 | Terrace Floor |
| 110 | Providing Plinth Protection of 600 m.m Width all around the plinth area of the proposed building with an under layer of 75m.m thick Plain Cement Concrete of proportion (1:4:8) using 40mm size hard crusher broken black granite stone metal compacted over a consolidated rigid ground and top of 50m.m thick Cement Concrete of proportion (1:2:4) with 12mm size hard crusher broken black granite stone chips laid to proper slope and gradient and top to be finished smooth with 12mm thick cement plaster in C.M(1:4) and protected the edges with 1st class K.B.brick massonary walls ( using the K.B Bricks of crushing strength not less than 75Kg/Sqcm) (half brick masonry 125mm deep) in Cement Mortar (1:6) including execution of required earth work, cost , conveyance, loading, unloading,royalities & taxes of all materials, cost all labour,Sundries, T&P, watering, curing etc complete in all respect as directed by the Engineer-in-charge. |
| 111 | Providing minimum 20 m.m thick Granite Slab Flooring using approved quality, shade and size of Granite Slab above 0.40sqm specially in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Granite Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Granite Tile if required including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering,Curing for required days including rubbing mechanically and wax polishing etc. complete in all respect as directed by the Engineer-in-charge. |
| 112 | Ground Floor |
| 113 | First Floor |
| 114 | Supplying,Fitting & Fixing minimum 20mm.Thick Granite slab in Dadoos Skirting using approved shade,quality and size of Granite slab of 10mm.Thick above 0.40 sqm) in all floors at all heights on 12 m.m thick cement plaster (1:3) using screened & washed sharp river sand for mortar with cement, grouted with neat white cement slurry and jointed with neat white cement slurry mixed with required approved shade of pigment to match the shade of the Granite slab including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour,Watering, Curing,Sundries and T&P, etc. required for the work complete as directed by the of Engineer-in-charge. |
| 115 | Ground Floor |
| 116 | First Floor |
| 117 | Providing edge moulding to 18 mm /20mm thick marble stone/Granite counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 118 | Ground Floor |
| 119 | First Floor |
| 120 | 25 m.m average thick artificial stone Flooring laid to proper slope with cement concrete of propertion (1:2:4) using approved quality of cement, screened &washed sharp river sand for motar with 12mm.to 20mm.size black hard crusher broken granite stone chips (20mm.size chips not to exceed 25%) of approved quality and from approved quarry, washed and cleaned, free from all debrises and slit, laid in two layers i.e. the bottom layer being 19mm.thick and top layer of 6mm. thick including chipping, chiselling, cleaning the top surface of the Roof slabs in upper floors, rounding of corners, watering and curing required for the work including cost, conveyance, loading,unloading,stacking,royalties and taxes of all materials,cost of all labour,sundries, T&P etc.complete in all respect as directed by the Engineer-in -charge. |
| 121 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR 2014 Item No. 22.5 converted OSR-2014) |
| 122 | First Floor |
| 123 | Providing and filling AAC block inside the sunken floor with all cost, conveyance, taxes transportation loading, unloading etc complete as directed by the Engineer-in-Charge |
| 124 | First Floor |
| 125 | Providing and fixing bright finished Aluminium hydraulic door closer (Best make of approved quality) with necessary accessories and screws etc.Complete |
| 126 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS 6315 marked for doors including cost of cutting floors as required embedding in floors and cover plates with brass pivots and single piece M.S Sheet outer box with side plate etc.complete as per direction of Engineer in charge.with S.S cover plateposition & plumb complete including cost,conveyance,loading,unloading,stacking and taxes of all materials ,cost of all labour, T&P ,sundries required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 127 | INTERNAL WIRING. |
| 128 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 129 | GROUP-A |
| 130 | GROUP-B |
| 131 | GROUP-C |
| 132 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 133 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 134 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 135 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 136 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 137 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 138 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 139 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 140 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 141 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 142 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 143 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 144 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 145 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 146 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 147 | Sub-Head II (Light fitting Fixture & Fan) |
| 148 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 149 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 150 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 151 | Supplying an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 152 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 153 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 154 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 155 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 156 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 157 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 158 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 3 years. |
| 159 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD ) Warranty on DB is 3 years. |
| 160 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 3 years. |
| 161 | Supplying and fixing 40 Amps rating, 4P, 415 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC). The MCB should be Replacement Warranty will be 3 years |
| 162 | Supplying and fixing 40 Amps rating, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC). The MCB should be Replacement Warranty will be 3 years |
| 163 | Supplying and fixing 40Amps DP 240 volts, RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years |
| 164 | Supplying and fixing 40Amps DP 240 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years |
| 165 | Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB , 4 way TPN BDB IC).The MCB should be Replacement Warranty will be 3 years |
| 166 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB , 4 way TPN BDB IC).The MCB should be Replacement Warranty will be 3 years |
| 167 | (Earthing) INSTALLATION |
| 168 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 169 | Providing and fixing 6SWG GI wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 170 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 171 | CABLING AND END TERMINATION MAIN AREA |
| 172 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 173 | 3.5core x 240 sq mm ( TO MAIN PANEL ) |
| 174 | 3.5core x 50 sq mm ( DG PANEL1 RUNS ) |
| 175 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade POLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 176 | 3.5core x 95 sq mm ( FOR FDB 1F, POWER ) |
| 177 | 4core x 16 sq mm (FDB LIGHT 1 RUN UPTO 1F ) |
| 178 | 3.5core x 35 sq mm |
| 179 | LAYING OF CABLE |
| 180 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 181 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 182 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 183 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 184 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 185 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 186 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 187 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 188 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 189 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 190 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 191 | 3.5 core x240 sq mm |
| 192 | 4 core x16sq mm |
| 193 | 3.5 core x35 sq mm |
| 194 | 3.5 core x95 sq mm |
| 195 | 3.5 core x50 sq mm |
| 196 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 197 | 50 mm dia |
| 198 | Providing,fixing and laying of following dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 199 | 200 mm dia |
| 200 | PANELS |
| 201 | MAIN CONTROL PANEL AT GF |
| 202 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 2 nos of 3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.. |
| 203 | In commer-1-01 number of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) (FROM TRANSFORMER) |
| 204 | In commer-2-01 number of 200A(160-200) 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for normal & DG ( ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) From DG |
| 205 | In commer-2- 01 no of 160A 4P onload changeover switch (Make-C&S/LK/Siemens/Schneider/Legrand) |
| 206 | Busbar- 04 numbers of 500 Amps al. bus bar busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 207 | Out going- 01 numbers of 100A 4P MCCB,25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) |
| 208 | Out going- 02 numbers of 160A 4P MCCB,,25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) |
| 209 | Out going- 04 numbers of 63A 4P MCCB,25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) |
| 210 | Out going- 4 numbers of 32A 4P MCB10kA,C series. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 211 | Out going- 4 numbers of 63A 4P MCB 10kA,C series. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 212 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 213 | (ii) Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) (SECURE/ Legrand ) |
| 214 | FDB RAW POWER AT 1F |
| 215 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD,40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.. |
| 216 | In commer- 01 no 160A 4P MCCB 25kA, with ROM & S. Link. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Icu=100%Ics)with shunt trip.with axulary for BMS or equievalant make. |
| 217 | Busbar- 04 numbers of 200Amps,50kA al. busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 218 | Out going- 04 nos 63A 4P MCB 10kA,C series for power BDB.( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 219 | Out going- 02 nos 32A 4P MCB 10kA,C series forExtra power BDB.( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 220 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 221 | (ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Secure).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Secure) with CTs 100/5A 3 nos class 1 type(Make-KAPPA /AE) |
| 222 | FLIIR LIGHT PANEL 1F |
| 223 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD40kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.. |
| 224 | In commer- 01 numbers of 63A 4P MCCB,16Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) |
| 225 | Busbar- 04 numbers of 100Amps al. busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 226 | Out going- 05 nos 32A 4P MCB 10kA, Cseries .( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 227 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 228 | (ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Secure).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Secure) with CTs 60/5A 3 nos class 1 type(Make-KAPPA /AE) |
| 229 | NB- This panel should have proper earth by suitable rated copper flat. |
| 230 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 231 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 232 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 233 | GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT |
| 234 | SAFETY EQUIPMENTS |
| 235 | Supply and Installation of Rubber Mats 12 thick of size 2000mmx1000mmx12mm thick Electrical tested with test certificate. |
| 236 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories Make-Ceasefire/Safex/Fireshield |
| 237 | Supply and Fixing of shock treatment charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 238 | Warning signs 415 V for Main LT panel rooms,Electrical rooms etc. |
| 239 | INTERNAL AND EXTERNAL PLUMBING WORKS |
| 240 | INTERNAL WATER SUPPLY WORKS |
| 241 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer - in - Charge. |
| 242 | 15mm dia. |
| 243 | 20mm dia. |
| 244 | 25mm dia. |
| 245 | 32mm dia. |
| 246 | 40mm dia. |
| 247 | Cutting holes through existing brick work including making good the same in cement mortar (1:4) from taking GI / PVC pipes and fittings etc all complete as per specification.{with 1:4 brick work in cement mortar [Excluding contractors profit & Over head charges.] 10 x 0.12 x 0.25 and 12mm thick cement plaster (1:4) [Excluding CP & OHC] 10 x 0.12 x 0.25} For 250mm Thick Wall. |
| 248 | Brick Holes Cutting |
| 249 | Cutting hole in R.C.C floor and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the hole after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm x 15cm x 25cm |
| 250 | Rcc & Roofs Cutting |
| 251 | Cutting grooves in pucca floors and wall for taking GI / PVC pipes and making good the damages as per specification complete. With Cement concrete (1:3:6) with metal [Excluding CP & OHC] and 12mm cement plaster (1:3) [Excluding CP & OHC] along with Cement punning [Excluding Cp & OHC] |
| 252 | Cutting grooves in pucca floors |
| 253 | Fixing of Brass/GM Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specification complete. |
| 254 | 25mm dia. |
| 255 | 32mm dia. |
| 256 | 40mm dia. |
| 257 | SOIL, WASTE,RAIN WATER AND VENT PIPE. |
| 258 | Providing and fixing on wall face unplasticised PVC sewer pipes conforming to IS:4985-2000 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion, (i) single socket pipes. |
| 259 | For 200mm diameter U-PVC SWR pipes. |
| 260 | 200mm Dia Upvc |
| 261 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion, (i) single socket pipes. |
| 262 | For 110mm diameter U-PVC SWR pipes. |
| 263 | 110mm Dia Upvc pipe |
| 264 | Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per the specification |
| 265 | 110mm INLET & OUTLET FLOOR TRAP |
| 266 | Providing and fixing on wall face PVC SWR moulded fittings/ accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including Jointing with seal ring leaving 10mm gap for thermal expansion. |
| 267 | SINGLE JUNCTION WITHOUT DOOR 110mm P.V.C SWR TYPE |
| 268 | 110MM DIA PLAIN BEND P.V.C SWR TYPE |
| 269 | 110MM DIA BEND WITH DOOR P.V.C SWR TYPE |
| 270 | 110MM DIA TEE W/O DOOR P.V.C SWR TYPE |
| 271 | 110MM DIA CROSS TEE W/O DOOR P.V.C SWR TYPE |
| 272 | 110MM DIA SINGLE \\"Y\\" P.V.C SWR TYPE |
| 273 | 110MM DIA DOUBLE \\"Y\\" P.V.C SWR TYPE |
| 274 | 110MM DIA COWEL AS PER P.V.C SWR TYPE |
| 275 | Fixing 110mm size 'P' trap (with horn or without horn) for water closet including jointing the trap with pan in cement mortar(1:1) as per specification. |
| 276 | 110MM DIA P.V.C SWR P-TRAP |
| 277 | Providing and fixing square mouth S.W. Gully trap grade A complete with CI grating brick masonary chamber and water tight C.I cover with frame of 300 X 300 mm size (inside) the weight of the cover to be not less than 4.53 kg as per standard design. Cement concrete 1:2:4 around and 1:5:10 in base 125 X 100mm 'P,Q or S' type |
| 278 | GULLY TRAP S.W. TYPE |
| 279 | Construction of inspection chamber including excavation with clear opening of 400 X 400 and upto the depth of 450 mm in all type of soil with half brick masonary with well burnt chimney bricks crushing strength not less than 40kg/cm2 and water absorption not more than 20% and in C.M (1:4), 100 mm thick PCC of M15 in foundation. 12mm thick inside and outside plastering with CM(1:3), finished with PCC M15 flooring of 75mm thick as per drawings, including covering of chamber by supplying and fixing CI frame and cover as per IS covering by M15 grade concrete complete as per approved drawing, including fixing required number of uPVC pipe pieces and plugging the same etc.,complete as per drawing and/or directed by Engineer. |
| 280 | INSPECTION CHAMBER |
| 281 | Constructing manholes with R.C.C top slab in (1:1½:3) mix, foundation concrete (1:4:8), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber with r.c.c precast cover complete as per specification. |
| 282 | MANHOLE |
| 283 | SANITARY FIXTURES & FITTINGS |
| 284 | Providing & Fixing Wash Down Water Closet (European type W.C pan) with integral 'P' trap conforming to JAQUAR MAKE of brand code CNS-WHT-751P180SPPZ and of viterous china make with Wall Hung Cistern, Drainage L Bend Pipe, Gasket and Installation Kit with PP normal close seat cover, hinges, Fixing Accessories all complete as per specification. |
| 285 | Water Closet (European type W.C pan) |
| 286 | Providing & Fixing Wash basin with hole for pillar tap conforming to IS : 2556 : Part 4-2004 / JAQUAR MAKE with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all compete as per specification. (Vitreous china flat back wash basin 560 x 415 x 200 mm (CODE CNS-WHT-801 JAQUAR MAKE) |
| 287 | Wash basin |
| 288 | Providing & Fixing of Standing urinal conforming to IS 2556 : Part 6-1996 including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification (White vitreous china clay half stall urinal flat back 355 x 340 x 535 mm (BRAND CODE URS - WHT - 13261H) JAQUAR MAKE) |
| 289 | Standing urinal |
| 290 | Providing & Fixing of Screw-down LONG BODY Bib Cocks (TAPS) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per the specification complete (Delux Head & high quality. (15mm diameter long body bib cock (CODE CON-107 KN) |
| 291 | Long body Bib Cock |
| 292 | Providing & Fixing of Screw-down ANGLE Stop Cocks conforming to CON-053KN (JAQUAR MAKE) of the following nominal sizes as per specification complete. (Deluxe Head & high quality), |
| 293 | (15mm diameter angle stop cock) |
| 294 | Angle Stop Cock |
| 295 | Providing & Fixing of Screw - down Consealed Stop Cocks conforming to CON-069FTK & ALD-089CQT (JAQUAR MAKE) of the following nominal sizes as per specification complete. (Deluxe Head & high quality), |
| 296 | (15mm diameter consealed stop cock) |
| 297 | Consealed Stop Cock |
| 298 | Providing & Fixing of Pillar Cock conforming to CON-CHR-011KN (JAQUAR MAKE) of the following nominal sizes as per specification complete. (Deluxe Head & high quality), |
| 299 | (15mm diameter pillar cock) |
| 300 | Pillar Cock |
| 301 | Providing & Fixing Chromium Plated Shower rose conforming OHS-1989 (JAQUAR MAKE) WITH SHA-477 SHOWER ARM INCLUDING polishing all complete as per specification . (Deluxe Head & Heavy quality) |
| 302 | Shower Head with Arm |
| 303 | Providing & Fixing Chromium Plated Liquid Soap Container complete with Chromium Plated brass brackets fixed to P.V.C plugs with Chromium Plated brass screws as per specification. (JAQUAR MAKE, BRAND ACN-1135N) |
| 304 | Liquid Soap Container |
| 305 | Providing & Fixing standard sized towel rail of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screw, complete as per specification. (Single towel rail 600mm long), (BRAND CODE ACN-1111SM), (Heavy Quality). |
| 306 | Towel Rail 600mm |
| 307 | Providing & Fixing standard sized towel ring of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screw, complete as per specification. (Towel Ring Round with Round Flange), (BRAND CODE ACN-1121BN), (Heavy Quality). |
| 308 | Towel Ring |
| 309 | Providing & Fixing 630mmX445mm bevelled edge mirror (JAQUAR MAKE-AKP-35795) of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification. |
| 310 | Edge mirror |
| 311 | Providing & Fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete as per specification |
| 312 | PVC waste pipe of 32mm |
| 313 | Providing & Fixing PVC inlet connection pipe of 15mm diameter and of nominal length for making connection with pillar cocks,cisterns and others with supply mains as per specification |
| 314 | PVC inlet connection pipe of 15mm |
| 315 | Providing & Fixing 32mm dia 80mm height CP brass waste coupling(JAQUAR MAKE Code - ALD-709) all complete as per specification |
| 316 | 32mm waste coupling |
| 317 | Providing & Fixing 100m dia SS floor grating all complete as per specification |
| 318 | SS Floor Grating |
| 319 | Providing & Fixing 15mm dia CP two way bib cock conforming to JAQUAR MAKE of brand code Jaquar KUP 35041PM , Fixing Accessories all complete as per specification |
| 320 | Two way bib cock |
| 321 | Providing & Fixing 15mm dia health faucet(Jaquar) conforming to JAQUAR MAKE all compete as per specification. |
| 322 | Health faucet |
| 323 | Supplying all materials, labour, T&P and fixing SS Sink without Drain board Nirali Elegance Ultra or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 324 | SS kitchen Sink |
| 325 | Supplying all materials, labour, T&P and fixing standard size Sink cock of Jaquar Cat. No.-CON 347KNM or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 326 | Sink Cock |
| 327 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks of 2000 Ltr capacity each conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge |
| 328 | 2000 Ltr capacity Tank |
| 329 | Providing all material,labour,T&P for fitting and fixing to wall or ceilling and bellow or over the ground level upvc solvent weld pipeSch-80 as per ASTM-D-1785 of gollowing nominal bore including fixing of required size upvc fitting like bend , tee, elbow ,offsets etc. and testing the joints with required water presure. The cost inclusive of earth work excavation in all kinds of soil ,back filling scaffolding ,all taxes,duties,transportation etc.as per specification & direction of Engineer -in -charge.Make: SUPREME/ASTRAL/ASHRIVAD. |
| 330 | 50mm dia. |
| 331 | Providing all material,labour,T&P and taxes of construction of brick masonary soka way pit using K.B Brick (1:4) having crushing strength not less than 75kg./sqcm for the remaining height (not less than 0.5 m) 12mm thick cement plaster (1:4) both inside and outside of top brick work, RCC 125 mm thick fitted with factory made SFRC manhole cover (medium duty) of size 500 mm dia including earthwork in excavation in hard soil,filling inside of the pit with 40mm size H.B.G metal for 150mm thick back filling the remaining pertion including top 0.5 mtr with excavated selected earth,levelling the surface around the chamber with the disposal of surplus earth,if any to a distance of 50 m as per the specification design and drawing including cost of curing and all tax, royality, cost, conveyance etc.all complete as per direction of EIC. |
| 332 | 1.50 dia x 3.0 m deep soakway pit |
| 333 | Supplying all material, labour, T&P and construction 50 users Spetic tank with Two years cleaning interval of iner size 7.7 x 2.4 x 1.7 (liquid depth) as per the approved drawing and specifications with over a bed of 100mm thick P.C.C (1:4:8) 150mm thick P.C.C (1:2:4) & 40 mm thick ( Avg.) A.S flooring inside wall plastering with 12mm thick C.P in C.M (1:4) including neat cement punning, outside wall plastering with 16mm thick C.P in C.M (1:4), RCC down graded chips with necessary reinforcement, centering and shuttering including 02 nos of SFRC manhole cover with frame of approved quality with inlet & out let chamber of size 750 x 750 x 450mm, one partition wall & two buffle walls, supply,fitting and fixing of necessary specials & fitting Tee, vent pipe ,pvc footrest including excavation of earth in all kind of soilincluding bailing out water and shoring, shuttering etc. as necessary and back filling the sides of tank and filling up the chamber with after. |
| 334 | 12 m.m thick cement plaster with cement mortar of mix(1:3) in all floors using approved quality of cement , screened &washed sharp river sand for motar , with neat cement punning finished smooth to the brick walls in dados skirting after racking out the |
| 335 | Cement Concrete 1:2:4 for benching of inlet & out let chamber |
| 336 | Providing fitting & fixing of 500mm dia pre cast factory made RCC man hole cover. |
| 337 | Porviding ,fiting and fixing of Poly propylene man hole steps. |
| 338 | Providing fittings & fixing of 110mmx1.80mlong SWR Type \\"A\\" Vent pipe with Cowl including construction of Cement concrete Pedestal of size 0.30 mx0.30 m x0.45m |
| 339 | Providing ,fitting&fixing of 150mm S.W Tee |
| 340 | Watch and ward for office Building and R&R Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail