| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 2 | Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. |
| 3 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 5 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 7 | 150x10 mm |
| 8 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 9 | 125 mm |
| 10 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 11 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 12 | 110 mm diameter |
| 13 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 14 | Bend 87.5° |
| 15 | 110 mm bend |
| 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 17 | 12 mm cement plaster of mix : |
| 18 | 1:6 (1 cement: 6 coarse sand) |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 20 | 1:6 (1 cement: 6 coarse sand) |
| 21 | White washing with lime to give an even shade : |
| 22 | Old work (two or more coats) . |
| 23 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 24 | Old work (one or more coats) |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 26 | One or more coats on old work. |
| 27 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 28 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 29 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 30 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 31 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge. |
| 32 | Providing and laying waterproofing treatment over the existing roof as directed by E-I-C and consisting of: |
| 33 | Cleaning and washing of the surface of existing roof to make it free from dust, oil, grease and loose particles by brushing properly exposing rugged surface and final washing. |
| 34 | Surface cleaning and crack filling: Repairing the damaged surface with Terroza ready plast, widening and deepening of cracks and fill all cracks by terraoza crack filler overlapping 25 mm on either side. |
| 35 | Moisturing the surface and application of Terroseal evenly over the surface to penetrate deep inside the poresand create elastomeric filmover it. |
| 36 | Application of heavy duty reinforced glass fibre net (Terromesh) of high tensile strength and alkali resistance over the surface covering vertical side walls. |
| 37 | Application of second coat Terroseal uniformly over the Terromesh. |
| 38 | Application of Terroza water proofing compound with water and terroseal over the surface with rolleror trowel like gurmala plaster to form a hydrophobic barrier for water and insulate the surface from heat and cold. |
| 39 | After complete drying of surface application of Terroza building guard in two or more coats with brush or roller and allow it to dry completely to seal the surface in all respect. The contractor has to carry out pre-manoon inspection every year for 5 years along with SDE(C)/ JTO(C) concern regarding the water tightness being intact & free from any cracks and a joint visit certificate having signature of SDE(C)/ JTO(C) & contractor shall be submitted to EE (C), BCD Jaipur. |
| 40 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 41 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 42 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 43 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 44 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 45 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 46 | 10 litre capacity - White |
| 47 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 48 | Semi rigid pipe |
| 49 | 32 mm dia |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 51 | 20 mm nominal outer dia. Pipes. |
| 52 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 53 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 54 | 15 mm nominal bore, 122 mm long. Weighing not less than 99 gms. |
| 55 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 56 | 20mm nominal bore, 89 mm long. Weighing not less than 88 gms. |
| 57 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 58 | 15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms. |
| 59 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 60 | 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. |
| 61 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 62 | 25 mm average thickness |
| 63 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 64 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 65 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. |
| 66 | 12 mm average thickness. |
| 67 | Repairing of doors and windows (Steel / wood/aluminium/pvc) at site with welding of hinges, sawing and repairing edges etc. and repairing of sides & jambs if required for their smooth functioning etc as directed by Engineer-in-charge. All T&P nails etc required for attending the work shall be arranged by the contractor and nothing extra shall be paid for. |
| 68 | Repairing of windows grill, railing etc by welding with Electric plant / gas plant including transportation of welding plant at site & other required T&P is to be arranged by Agency. MS sections shall be paid for separately. |
| 69 | Triming of big trees (Height more than 4 m) near Compound wall and building. All tools and plants i/c safety belts and helmets required for triming to be arreaged by agency i/c disposal of triming branches and leaves upto municipal dumping ground at any lead all complete as per direction of E-In-C. |
| 70 | Repairing and service of rolling shutter by taking out shutter top cover and cutting and tightening spring with welding and refixing the same in proper to make it operational including greasing ,oils,welding ,spring,ball bearing all complete as per direction of engineer incharge. |
| 71 | Credit of steel Please Enable Macros to View BoQ information |